메뉴 건너뛰기




Volumn 16, Issue 1, 2009, Pages 257-264

Duration and mechanism for suppressive effect of triazole-based passivators on copper-sulfide deposition on insulating paper

Author keywords

Copper; Copper compounds; Oil insulation; Paper insulation; Sulfur; Sulfur compounds; Transformer oil; Transformers

Indexed keywords

COPPER; DISSOLUTION; ELECTRIC TRANSFORMER INSULATION; ELECTRIC TRANSFORMER TESTING; HEATING; HYDROCARBONS; INSULATING MATERIALS; INSULATING OIL; INSULATION; MINERAL OILS; NITROGEN COMPOUNDS; OIL FILLED TRANSFORMERS; PAPER; SECONDARY ION MASS SPECTROMETRY; SULFUR; SULFUR COMPOUNDS; SULFUR DETERMINATION; SURFACE REACTIONS;

EID: 61349126667     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2009.4784575     Document Type: Article
Times cited : (76)

References (17)
  • 1
    • 61349156879 scopus 로고    scopus 로고
    • CIGRE WG A2-32, Copper sulphide in transformer insulation, ELECTRA, No. 230, pp. 12-17, 2007.
    • CIGRE WG A2-32, "Copper sulphide in transformer insulation," ELECTRA, No. 230, pp. 12-17, 2007.
  • 2
    • 61349089313 scopus 로고    scopus 로고
    • CIGRE TF A2.31, Copper sulphide in transformer insulation, ELECTRA, No. 224, pp. 20-23, Feb. 2006.
    • CIGRE TF A2.31, "Copper sulphide in transformer insulation," ELECTRA, No. 224, pp. 20-23, Feb. 2006.
  • 3
    • 61349188452 scopus 로고    scopus 로고
    • CIGRE WG A2-32, Copper sulphide in transformer insulation, Interim Report No. 1, 2006.
    • CIGRE WG A2-32, "Copper sulphide in transformer insulation," Interim Report No. 1, 2006.
  • 5
    • 61349184620 scopus 로고    scopus 로고
    • ABINEE, June 2-3, Sao Paulo, Brazil. Available
    • ABINEE, Workshop on Corrosive Sulphur in Oil, June 2-3 2005, Sao Paulo, Brazil. Available: http://www.cigre-a2.org/Site/Publications download/ABINEEID44VER52.zip.
    • (2005) Workshop on Corrosive Sulphur in Oil
  • 7
    • 61349187810 scopus 로고    scopus 로고
    • S. Eechhoudt, J. Van. Peteghem and L. Kinable, Corrosive sulphur in transformer oils: Impact on maintenance strategy and transformer asset management and current research with in the Belgian power industry, CIGRE, SC A2&Dl, Colloquium, Belgium, Paper PS2-05, 2007.
    • S. Eechhoudt, J. Van. Peteghem and L. Kinable, "Corrosive sulphur in transformer oils: Impact on maintenance strategy and transformer asset management and current research with in the Belgian power industry", CIGRE, SC A2&Dl, Colloquium, Belgium, Paper PS2-05, 2007.
  • 8
    • 61349099631 scopus 로고    scopus 로고
    • A point of view from the Brazilian utilities or how the utilities in Brazil manage to achieve these objectives in a country with high energy demand
    • Belgium, Paper PS0-01
    • G.M. Bastos, "A point of view from the Brazilian utilities or how the utilities in Brazil manage to achieve these objectives in a country with high energy demand", CIGRE, SC A2&Dl, Colloquium, Belgium, Paper PS0-01, 2007.
    • (2007) CIGRE, SC A2&Dl, Colloquium
    • Bastos, G.M.1
  • 10
    • 34547873512 scopus 로고    scopus 로고
    • Copper Dissolution and Metal Passivators in Insulating Oil
    • P. Wiklund, M. Levin and B. Pahlavanpour, "Copper Dissolution and Metal Passivators in Insulating Oil", IEEE Electr. Insul. Mag., Vol. 23, No. 4, pp. 6-14, 2007.
    • (2007) IEEE Electr. Insul. Mag , vol.23 , Issue.4 , pp. 6-14
    • Wiklund, P.1    Levin, M.2    Pahlavanpour, B.3
  • 11
    • 61349130856 scopus 로고    scopus 로고
    • JISC 2320, Electrical insulating oils, Japanese Industrial Standards Committee, 1999.
    • JISC 2320, Electrical insulating oils, Japanese Industrial Standards Committee, 1999.
  • 12
    • 33847721943 scopus 로고    scopus 로고
    • Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
    • IEC 60296
    • IEC 60296, Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear, 2003.
    • (2003)
  • 13
    • 61349182414 scopus 로고    scopus 로고
    • Standard Test Method for Corrosive Sulfur in Electrical Insulating Oils
    • ASTM D1275-03, ASTM International
    • ASTM D1275-03, Standard Test Method for Corrosive Sulfur in Electrical Insulating Oils, ASTM International, 2003.
    • (2003)
  • 14
    • 84862669895 scopus 로고    scopus 로고
    • IEEE/PES Transformers Committee, Oct, Available
    • IEEE/PES Transformers Committee. (2005, Oct). The Evolving Problems of Corrosive Sulfur in Transformer oil. Available: http://www. transformerscommittee.ore/info/F05/F05-CorrosiveSulfurPresentation.pdf
    • (2005) The Evolving Problems of Corrosive Sulfur in Transformer oil
  • 15
    • 0344000044 scopus 로고
    • Benzotriazole: A review for conservators
    • C. Sease, "Benzotriazole: a review for conservators", Studies in Conservation Vol. 23, pp. 76-85, 1978.
    • (1978) Studies in Conservation , vol.23 , pp. 76-85
    • Sease, C.1
  • 16
    • 0037039621 scopus 로고    scopus 로고
    • Comparative Study of Inhibition Effects of Benzotriazole for Metals in Neutral Solutions As Observed with Surface-Enhanced Raman Spectroscopy
    • P. G. Cao, J. L, Yao, J. W. Zheng, R. A. Gu and Z. Q. Tian, "Comparative Study of Inhibition Effects of Benzotriazole for Metals in Neutral Solutions As Observed with Surface-Enhanced Raman Spectroscopy", Langmuir, Vol. 18, pp. 100-104, 2002.
    • (2002) Langmuir , vol.18 , pp. 100-104
    • Cao, P.G.1    Yao, J.L.2    Zheng, J.W.3    Gu, R.A.4    Tian, Z.Q.5
  • 17
    • 0037437856 scopus 로고    scopus 로고
    • Evaluation of the Cu-CMP process by TOF-SIMS and XPS: Time dependence pf Cu surface adsorbents and oxidation states
    • A. Nishi, M. Sato, T. Miki and Y. Fukui, "Evaluation of the Cu-CMP process by TOF-SIMS and XPS: time dependence pf Cu surface adsorbents and oxidation states", Appl. Surface Sci, Vol. 203/204, pp. 470-472, 2003.
    • (2003) Appl. Surface Sci , vol.203-204 , pp. 470-472
    • Nishi, A.1    Sato, M.2    Miki, T.3    Fukui, Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.