메뉴 건너뛰기




Volumn 33, Issue 2, 2009, Pages 101-106

Investigation of the arterial stiffness on renal artery doppler sonograms

Author keywords

Arterial stiffness; Compliance; Doppler ultrasound; Savitzky Golay smoothing method; Short time Fourier transformation

Indexed keywords


EID: 61349117480     PISSN: 01485598     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10916-008-9169-1     Document Type: Article
Times cited : (4)

References (12)
  • 2
    • 61349191184 scopus 로고    scopus 로고
    • Hodder Arnold New York
    • Nichols, W. W., and O' Rourke, M. F., McDonald's blood flow in arteries. New York: Hodder Arnold, 2005.
    • (2005)
    • Nichols, W.W.1    O'Rourke, M.F.2
  • 5
    • 0030560892 scopus 로고    scopus 로고
    • Nonstationarity broadening reduction in pulsed Doppler spectrum measurements using time-frequency estimators
    • 12
    • J. C. S. Cardoso M. G. Ruano P. J. Fish 1996 Nonstationarity broadening reduction in pulsed Doppler spectrum measurements using time-frequency estimators IEEE Trans. Biomed. Eng 43 12 1176 1186
    • (1996) IEEE Trans. Biomed. Eng , vol.43 , pp. 1176-1186
    • Cardoso, J.C.S.1    Ruano, M.G.2    Fish, P.J.3
  • 6
    • 0035354918 scopus 로고    scopus 로고
    • Fast edge-preserving noise reduction for ultrasound images
    • C. Chinrungrueng A. Suvichakorn 2001 Fast edge-preserving noise reduction for ultrasound images IEEE Trans. Nucl. Sci 48 849 854
    • (2001) IEEE Trans. Nucl. Sci , vol.48 , pp. 849-854
    • Chinrungrueng, C.1    Suvichakorn, A.2
  • 7
    • 0042553279 scopus 로고
    • Smoothing and differentiation of data by simplified least squares procedures
    • A. Savitzky M. J. E. Golay 1964 Smoothing and differentiation of data by simplified least squares procedures Anal. Chem 36 1627 1639
    • (1964) Anal. Chem , vol.36 , pp. 1627-1639
    • Savitzky, A.1    Golay, M.J.E.2
  • 9
    • 0020076609 scopus 로고
    • Digital Fourier techniques in the diagnosis and quantification of aortic stenosis with pulse-Doppler echocardiography
    • S. R. Cannon K. L. Richards W. T. Rollwitz 1982 Digital Fourier techniques in the diagnosis and quantification of aortic stenosis with pulse-Doppler echocardiography J. Clin. Ultrasound 10 101 117
    • (1982) J. Clin. Ultrasound , vol.10 , pp. 101-117
    • Cannon, S.R.1    Richards, K.L.2    Rollwitz, W.T.3
  • 10
    • 0021884610 scopus 로고
    • In vitro comparison of alternative methods for quantifying the severity of Doppler spectral broadening for the diagnosis of carotid arterial occlusive disease
    • 3
    • P. G. Kalman K. W. Johnston P. Zuech M. Kassam K. Poots 1985 In vitro comparison of alternative methods for quantifying the severity of Doppler spectral broadening for the diagnosis of carotid arterial occlusive disease Ultrasound Med. Biol 11 3 435 440
    • (1985) Ultrasound Med. Biol , vol.11 , pp. 435-440
    • Kalman, P.G.1    Johnston, K.W.2    Zuech, P.3    Kassam, M.4    Poots, K.5
  • 12
    • 23844496668 scopus 로고    scopus 로고
    • Real-time speckle reduction and coherence enhancement of ultrasound images based on mixture of anisotropic Savitzky-Golay filters
    • 1
    • C. Chinrungrueng P. Toonkum 2004 Real-time speckle reduction and coherence enhancement of ultrasound images based on mixture of anisotropic Savitzky-Golay filters IEEE Nucl. Sci. Symp. Conf 7 1 4212 4216
    • (2004) IEEE Nucl. Sci. Symp. Conf , vol.7 , pp. 4212-4216
    • Chinrungrueng, C.1    Toonkum, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.