Dedicated breast CT: Radiation dose and image quality evaluation
-
J. M. Boone, T. R. Nelson, K. K. Lindfors, and J. A. Seibert, " Dedicated breast CT: Radiation dose and image quality evaluation.," Radiology 221 (3), 657-67 (2001).
-
(2001)
Radiology
, vol.221
, Issue.3
, pp. 657-667
-
-
Boone, J.M.1
Nelson, T.R.2
Lindfors, K.K.3
Seibert, J.A.4
-
2
-
-
0035999405
-
Cone-beam volume CT breast imaging: Feasibility study
-
B. Chen and R. Ning, " Cone-beam volume CT breast imaging: Feasibility study.," Med. Phys. 29 (5), 755-70 (2002).
-
(2002)
Med. Phys.
, vol.29
, Issue.5
, pp. 755-770
-
-
Chen, B.1
Ning, R.2
-
3
-
-
1242316319
-
A comprehensive analysis of DgN(CT) coefficients for pendant-geometry cone-beam breast computed tomography
-
J. M. Boone, N. Shah, and T. R. Nelson, " A comprehensive analysis of DgN(CT) coefficients for pendant-geometry cone-beam breast computed tomography.," Med. Phys. 31 (2), 226-35 (2004).
-
(2004)
Med. Phys.
, vol.31
, Issue.2
, pp. 226-235
-
-
Boone, J.M.1
Shah, N.2
Nelson, T.R.3
-
4
-
-
33645000127
-
Technique factors and their relationship to radiation dose in pendant geometry breast CT
-
J. M. Boone, A. L. Kwan, J. A. Seibert, N. Shah, K. K. Lindfors, and T. R. Nelson, " Technique factors and their relationship to radiation dose in pendant geometry breast CT.," Med. Phys. 32 (12), 3767-76 (2005).
-
(2005)
Med. Phys.
, vol.32
, Issue.12
, pp. 3767-3776
-
-
Boone, J.M.1
Kwan, A.L.2
Seibert, J.A.3
Shah, N.4
Lindfors, K.K.5
Nelson, T.R.6
-
5
-
-
33846292870
-
Computed tomography for imaging the breast
-
J. M. Boone, A. L. Kwan, K. Yang, G. W. Burkett, K. K. Lindfors, and T. R. Nelson, " Computed tomography for imaging the breast.," J Mammary Gland Biol Neoplasia 11 (2), 103-111 (2006).
-
(2006)
J Mammary Gland Biol Neoplasia
, vol.11
, Issue.2
, pp. 103-111
-
-
Boone, J.M.1
Kwan, A.L.2
Yang, K.3
Burkett, G.W.4
Lindfors, K.K.5
Nelson, T.R.6
-
6
-
-
33845955419
-
Evaluating the impact of x-ray spectral shape on image quality in flat-panel CT breast imaging
-
S. J. Glick, S. Thacker, X. Gong, and B. Liu, " Evaluating the impact of x-ray spectral shape on image quality in flat-panel CT breast imaging.," Med. Phys. 34 (1), 5-24 (2007).
-
(2007)
Med. Phys.
, vol.34
, Issue.1
, pp. 5-24
-
-
Glick, S.J.1
Thacker, S.2
Gong, X.3
Liu, B.4
-
7
-
-
25644435753
-
Evaluation of x-ray scatter properties in a dedicated cone-beam breast CT scanner
-
A. L. Kwan, J. M. Boone, and N. Shah, " Evaluation of x-ray scatter properties in a dedicated cone-beam breast CT scanner.," Med. Phys. 32 (9), 2967-2975 (2005).
-
(2005)
Med. Phys.
, vol.32
, Issue.9
, pp. 2967-2975
-
-
Kwan, A.L.1
Boone, J.M.2
Shah, N.3
-
8
-
-
3042784991
-
Microcalcification detection using cone-beam CT mammography with a flat-panel imager
-
X. Gong, A. A. Vedula, and S. J. Glick, " Microcalcification detection using cone-beam CT mammography with a flat-panel imager.," Phys. Med. Biol. 49 (11), 2183-95 (2004).
-
(2004)
Phys. Med. Biol.
, vol.49
, Issue.11
, pp. 2183-2195
-
-
Gong, X.1
Vedula, A.A.2
Glick, S.J.3
-
9
-
-
33645524546
-
A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging
-
X. Gong, S. J. Glick, B. Liu, A. A. Vedula, and S. Thacker, " A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging.," Med. Phys. 33 (4), 1041-1052 (2006).
-
(2006)
Med. Phys.
, vol.33
, Issue.4
, pp. 1041-1052
-
-
Gong, X.1
Glick, S.J.2
Liu, B.3
Vedula, A.A.4
Thacker, S.5
-
10
-
-
12744255227
-
Normalized glandular dose (DgN) coefficients for flat-panel CT breast imaging
-
S. C. Thacker and S. J. Glick, " Normalized glandular dose (DgN) coefficients for flat-panel CT breast imaging.," Phys. Med. Biol. 49 (24), 5433-5444 (2004).
-
(2004)
Phys. Med. Biol.
, vol.49
, Issue.24
, pp. 5433-5444
-
-
Thacker, S.C.1
Glick, S.J.2
-
11
-
-
1942484757
-
Simulation study of a quasi-monochromatic beam for x-ray computed mammotomography
-
R. L. McKinley, M. P. Tornai, E. Samei, and M. L. Bradshaw, " Simulation study of a quasi-monochromatic beam for x-ray computed mammotomography.," Med. Phys. 31 (4), 800-813 (2004).
-
(2004)
Med. Phys.
, vol.31
, Issue.4
, pp. 800-813
-
-
McKinley, R.L.1
Tornai, M.P.2
Samei, E.3
Bradshaw, M.L.4
-
12
-
-
34347388438
-
Visibility of microcalcification in cone beam breast CT: Effects of x-ray tube voltage and radiation dose
-
C. J. Lai, C. C. Shaw, L. Chen, M. C. Altunbas, X. Liu, T. Han, T. Wang, W. T. Yang, G. J. Whitman, and S. J. Tu, " Visibility of microcalcification in cone beam breast CT: effects of x-ray tube voltage and radiation dose.," Med. Phys. 34 (7), 2995-3004 (2007).
-
(2007)
Med. Phys.
, vol.34
, Issue.7
, pp. 2995-3004
-
-
Lai, C.J.1
Shaw, C.C.2
Chen, L.3
Altunbas, M.C.4
Liu, X.5
Han, T.6
Wang, T.7
Yang, W.T.8
Whitman, G.J.9
Tu, S.J.10
-
13
-
-
34447301819
-
Computer modeling of the spatial resolution properties of a dedicated breast CT system
-
K. Yang, A. L. Kwan, and J. M. Boone, " Computer modeling of the spatial resolution properties of a dedicated breast CT system.," Med. Phys. 34 (6), 2059-2069 (2007).
-
(2007)
Med. Phys.
, vol.34
, Issue.6
, pp. 2059-2069
-
-
Yang, K.1
Kwan, A.L.2
Boone, J.M.3
-
14
-
-
42449130947
-
Monte carlo and phantom study of the radiation dose to the body from dedicated CT of the breast
-
I. Sechopoulos, S. Vedantham, S. Suryanarayanan, C. J. D'Orsi, and A. Karellas, " Monte carlo and phantom study of the radiation dose to the body from dedicated CT of the breast.," Radiology 247 (1), 98-105 (2008).
-
(2008)
Radiology
, vol.247
, Issue.1
, pp. 98-105
-
-
Sechopoulos, I.1
Vedantham, S.2
Suryanarayanan, S.3
D'Orsi, C.J.4
Karellas, A.5
-
15
-
-
36448987873
-
Dedicated cone-beam breast CT: Feasibility study with surgical mastectomy specimens
-
W. T. Yang, S. Carkaci, L. Chen, C. J. Lai, A. Sahin, G. J. Whitman, and C. C. Shaw, " Dedicated cone-beam breast CT: feasibility study with surgical mastectomy specimens.," AJR, Am. J. Roentgenol. 189 (6), 1312-1315 (2007).
-
(2007)
AJR, Am. J. Roentgenol.
, vol.189
, Issue.6
, pp. 1312-1315
-
-
Yang, W.T.1
Carkaci, S.2
Chen, L.3
Lai, C.J.4
Sahin, A.5
Whitman, G.J.6
Shaw, C.C.7
-
16
-
-
40949119836
-
Dedicated breast CT: Initial clinical experience
-
K. K. Lindfors, J. M. Boone, T. R. Nelson, K. Yang, A. L. Kwan, and D. F. Miller, " Dedicated breast CT: Initial clinical experience.," Radiology 246 (3), 725-733 (2008).
-
(2008)
Radiology
, vol.246
, Issue.3
, pp. 725-733
-
-
Lindfors, K.K.1
Boone, J.M.2
Nelson, T.R.3
Yang, K.4
Kwan, A.L.5
Miller, D.F.6
-
17
-
-
0025429744
-
Cone-beam tomography: Recent advances and a tutorial review
-
B. D. Smith, " Cone-beam tomography: Recent advances and a tutorial review.," Opt. Eng. 29 (5), 524-534 (1990).
-
(1990)
Opt. Eng.
, vol.29
, Issue.5
, pp. 524-534
-
-
Smith, B.D.1
-
18
-
-
0038710363
-
Flat panel detector-based cone beam computed tomography with a circle-plus-two-arcs data acquisition orbit: Preliminary phantom study
-
R. Ning, X. Tang, D. Conover, and R. Yu, " Flat panel detector-based cone beam computed tomography with a circle-plus-two-arcs data acquisition orbit: preliminary phantom study.," Med. Phys. 30 (7), 1694-1705 (2003).
-
(2003)
Med. Phys.
, vol.30
, Issue.7
, pp. 1694-1705
-
-
Ning, R.1
Tang, X.2
Conover, D.3
Yu, R.4
-
19
-
-
0034977534
-
A cone beam filtered backprojection (CB-FBP) reconstruction algorithm for a circle-plus-two-arc orbit
-
X. Tang and R. Ning, " A cone beam filtered backprojection (CB-FBP) reconstruction algorithm for a circle-plus-two-arc orbit.," Med. Phys. 28 (6), 1042-1055 (2001).
-
(2001)
Med. Phys.
, vol.28
, Issue.6
, pp. 1042-1055
-
-
Tang, X.1
Ning, R.2
-
20
-
-
33749422544
-
Cone-beam mammo-computed tomography from data along two tilting arcs
-
K. Zeng, H. Yu, L. L. Fajardo, and G. Wang, " Cone-beam mammo-computed tomography from data along two tilting arcs.," Med. Phys. 33 (10), 3621-3633 (2006).
-
(2006)
Med. Phys.
, vol.33
, Issue.10
, pp. 3621-3633
-
-
Zeng, K.1
Yu, H.2
Fajardo, L.L.3
Wang, G.4
-
21
-
-
0019978056
-
The effects of scatter in x-ray computed tomography
-
P. M. Joseph and R. D. Spital, " The effects of scatter in x-ray computed tomography.," Med. Phys. 9 (4), 464-472 (1982).
-
(1982)
Med. Phys.
, vol.9
, Issue.4
, pp. 464-472
-
-
Joseph, P.M.1
Spital, R.D.2
-
22
-
-
0020364887
-
Compton scatter effects in CT reconstructions
-
G. H. Glover, " Compton scatter effects in CT reconstructions., " Med. Phys. 9 (6), 860-867 (1982).
-
(1982)
Med. Phys.
, vol.9
, Issue.6
, pp. 860-867
-
-
Glover, G.H.1
-
23
-
-
0035110308
-
Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter
-
J. H. Siewerdsen and D. A. Jaffray, " Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter.," Med. Phys. 28 (2), 220-231 (2001).
-
(2001)
Med. Phys.
, vol.28
, Issue.2
, pp. 220-231
-
-
Siewerdsen, J.H.1
Jaffray, D.A.2
-
24
-
-
33748309392
-
Magnitude and effects of x-ray scatter in a 256-slice CT scanner
-
M. Endo, S. Mori, T. Tsunoo, and H. Miyazaki, " Magnitude and effects of x-ray scatter in a 256-slice CT scanner.," Med. Phys. 33 (9), 3359-3368 (2006).
-
(2006)
Med. Phys.
, vol.33
, Issue.9
, pp. 3359-3368
-
-
Endo, M.1
Mori, S.2
Tsunoo, T.3
Miyazaki, H.4
-
25
-
-
11244314035
-
The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors
-
J. H. Siewerdsen, D. J. Moseley, B. Bakhtiar, S. Richard, and D. A. Jaffray, " The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors.," Med. Phys. 31 (12), 3506-3520 (2004).
-
(2004)
Med. Phys.
, vol.31
, Issue.12
, pp. 3506-3520
-
-
Siewerdsen, J.H.1
Moseley, D.J.2
Bakhtiar, B.3
Richard, S.4
Jaffray, D.A.5
-
26
-
-
14644437677
-
Photon counting computed tomography: Concept and initial results
-
P. M. Shikhaliev, T. Xu, and S. Molloi, " Photon counting computed tomography: Concept and initial results.," Med. Phys. 32 (2), 427-436 (2005).
-
(2005)
Med. Phys.
, vol.32
, Issue.2
, pp. 427-436
-
-
Shikhaliev, P.M.1
Xu, T.2
Molloi, S.3
-
27
-
-
0021868276
-
Scatter rejection by air gaps: An empirical model
-
J. A. Sorenson and J. Floch, " Scatter rejection by air gaps: An empirical model.," Med. Phys. 12 (3), 308-316 (1985).
-
(1985)
Med. Phys.
, vol.12
, Issue.3
, pp. 308-316
-
-
Sorenson, J.A.1
Floch, J.2
-
28
-
-
0023752571
-
X-ray scatter removal by deconvolution
-
J. A. Seibert and J. M. Boone, " X-ray scatter removal by deconvolution.," Med. Phys. 15 (4), 567-575 (1988).
-
(1988)
Med. Phys.
, vol.15
, Issue.4
, pp. 567-575
-
-
Seibert, J.A.1
Boone, J.M.2
-
29
-
-
33748518881
-
Combining deterministic and Monte Carlo calculations for fast estimation of scatter intensities in CT
-
Y. Kyriakou, T. Riedel, and W. A. Kalender, " Combining deterministic and Monte Carlo calculations for fast estimation of scatter intensities in CT.," Phys. Med. Biol. 51 (18), 4567-4586 (2006).
-
(2006)
Phys. Med. Biol.
, vol.51
, Issue.18
, pp. 4567-4586
-
-
Kyriakou, Y.1
Riedel, T.2
Kalender, W.A.3
-
30
-
-
2442689175
-
X-ray scatter correction algorithm for cone beam CT imaging
-
R. Ning, X. Tang, and D. Conover, " X-ray scatter correction algorithm for cone beam CT imaging.," Med. Phys. 31 (5), 1195-202 (2004).
-
(2004)
Med. Phys.
, vol.31
, Issue.5
, pp. 1195-1202
-
-
Ning, R.1
Tang, X.2
Conover, D.3
-
31
-
-
33645286933
-
Efficient Monte Carlo based scatter artifact reduction in cone-beam micro-CT
-
W. Zbijewski and F. J. Beekman, " Efficient Monte Carlo based scatter artifact reduction in cone-beam micro-CT.," IEEE Trans. Med. Imaging 25, 817-827 (2006).
-
(2006)
IEEE Trans. Med. Imaging
, vol.25
, pp. 817-827
-
-
Zbijewski, W.1
Beekman, F.J.2
-
32
-
-
0025890218
-
Method for estimating the intensity of scattered radiation using a scatter generation model
-
M. Honda, K. Kikuchi, and K. Komatsu, " Method for estimating the intensity of scattered radiation using a scatter generation model.," Med. Phys. 18 (2), 219-226 (1991).
-
(1991)
Med. Phys.
, vol.18
, Issue.2
, pp. 219-226
-
-
Honda, M.1
Kikuchi, K.2
Komatsu, K.3
-
33
-
-
33845562622
-
Scatter correction method for x-ray CT using primary modulation: Theory and preliminary results
-
L. Zhu, N. R. Bennett, and R. Fahrig, " Scatter correction method for x-ray CT using primary modulation: Theory and preliminary results.," IEEE Trans. Med. Imaging 25, 1573-1587 (2006).
-
(2006)
IEEE Trans. Med. Imaging
, vol.25
, pp. 1573-1587
-
-
Zhu, L.1
Bennett, N.R.2
Fahrig, R.3
-
34
-
-
34347387545
-
A post-reconstruction method to correct cupping artifacts in cone beam breast computed tomography
-
M. C. Altunbas, C. C. Shaw, L. Chen, C. Lai, X. Liu, T. Han, and T. Wang, " A post-reconstruction method to correct cupping artifacts in cone beam breast computed tomography.," Med. Phys. 34 (7), 3109-3118 (2007).
-
(2007)
Med. Phys.
, vol.34
, Issue.7
, pp. 3109-3118
-
-
Altunbas, M.C.1
Shaw, C.C.2
Chen, L.3
Lai, C.4
Liu, X.5
Han, T.6
Wang, T.7
-
35
-
-
4644300604
-
An inverse-geometry volumetric CT system with a large-area scanned source: A feasibility study
-
T. G. Schmidt, R. Fahrig, N. J. Pelc, and E. G. Solomon, " An inverse-geometry volumetric CT system with a large-area scanned source: A feasibility study.," Med. Phys. 31 (9), 2623-2627 (2004).
-
(2004)
Med. Phys.
, vol.31
, Issue.9
, pp. 2623-2627
-
-
Schmidt, T.G.1
Fahrig, R.2
Pelc, N.J.3
Solomon, E.G.4
-
36
-
-
33744785137
-
A prototype table-top inverse-geometry volumetric CT system
-
T. G. Schmidt, J. Star-Lack, N. R. Bennett, S. R. Mazin, E. G. Solomon, R. Fahrig, and N. J. Pelc, " A prototype table-top inverse-geometry volumetric CT system.," Med. Phys. 33 (6), 1867-1878 (2006).
-
(2006)
Med. Phys.
, vol.33
, Issue.6
, pp. 1867-1878
-
-
Schmidt, T.G.1
Star-Lack, J.2
Bennett, N.R.3
Mazin, S.R.4
Solomon, E.G.5
Fahrig, R.6
Pelc, N.J.7
-
37
-
-
0032594389
-
Scanning-beam digital x-ray (SBDX) system for cardiac angiography
-
(SPIE, San Diego, CA), Vol.
-
E. G. Solomon, B. P. Wilfley, M. S. Van Lysel, A. W. Joseph, and J. A. Heanue, " Scanning-beam digital x-ray (SBDX) system for cardiac angiography.," Medical Imaging 1999: Physics of Medical Imaging (SPIE, San Diego, CA, 1999), Vol. 3659, pp. 246-257.
-
(1999)
Medical Imaging 1999: Physics of Medical Imaging
, vol.3659
, pp. 246-257
-
-
Solomon, E.G.1
Wilfley, B.P.2
Van Lysel, M.S.3
Joseph, A.W.4
Heanue, J.A.5
-
38
-
-
0032594570
-
CdZnTe detector array for a scanning-beam digital x-ray system
-
(SPIE, San Diego, CA), Vol.
-
J. A. Heanue, D. A. Pearson, and R. E. Melen, " CdZnTe detector array for a scanning-beam digital x-ray system.," Medical Imaging 1999: Physics of Medical Imaging (SPIE, San Diego, CA, 1999), Vol. 3659, pp. 718-725.
-
(1999)
Medical Imaging 1999: Physics of Medical Imaging
, vol.3659
, pp. 718-725
-
-
Heanue, J.A.1
Pearson, D.A.2
Melen, R.E.3
-
40
-
-
0030657556
-
An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kv
-
J. M. Boone and J. A. Seibert, " An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kv.," Med. Phys. 24 (11), 1661-1670 (1997).
-
(1997)
Med. Phys.
, vol.24
, Issue.11
, pp. 1661-1670
-
-
Boone, J.M.1
Seibert, J.A.2
-
41
-
-
0018316082
-
Absorbed radiation dose in mammography
-
G. R. Hammerstein, D. W. Miller, D. R. White, M. E. Masterson, H. Q. Woodard, and J. S. Laughlin, " Absorbed radiation dose in mammography.," Radiology 130 (2), 485-491 (1979).
-
(1979)
Radiology
, vol.130
, Issue.2
, pp. 485-491
-
-
Hammerstein, G.R.1
Miller, D.W.2
White, D.R.3
Masterson, M.E.4
Woodard, H.Q.5
Laughlin, J.S.6
-
42
-
-
0003998975
-
-
(Prentice-Hall, Upper Saddle River, NJ).
-
A. Macovski, Medical Imaging Systems (Prentice-Hall, Upper Saddle River, NJ, 1983).
-
(1983)
Medical Imaging Systems
-
-
MacOvski, A.1
-
43
-
-
0023196389
-
X-ray characterisation of normal and neoplastic breast tissues
-
P. C. Johns and M. J. Yaffe, " X-ray characterisation of normal and neoplastic breast tissues.," Phys. Med. Biol. 32 (6), 675-695 (1987).
-
(1987)
Phys. Med. Biol.
, vol.32
, Issue.6
, pp. 675-695
-
-
Johns, P.C.1
Yaffe, M.J.2
-
44
-
-
2542455683
-
Accelerated simulation of cone beam x-ray scatter projections
-
A. P. Colijn and F. J. Beekman, " Accelerated simulation of cone beam x-ray scatter projections.," IEEE Trans. Med. Imaging 23 (5), 584-590 (2004).
-
(2004)
IEEE Trans. Med. Imaging
, vol.23
, Issue.5
, pp. 584-590
-
-
Colijn, A.P.1
Beekman, F.J.2
-
45
-
-
0021445363
-
Practical cone-beam algorithm
-
L. A. Feldkamp, L. C. Davis, and J. W. Kress, " Practical cone-beam algorithm.," J. Opt. Soc. Am. A 1 (6), 612-619 (1984).
-
(1984)
J. Opt. Soc. Am. a
, vol.1
, Issue.6
, pp. 612-619
-
-
Feldkamp, L.A.1
Davis, L.C.2
Kress, J.W.3
-
46
-
-
0001380259
-
A fast rebinning algorithm for 3D positron emission tomography using John's equation
-
M. Defrise and X. Liu, " A fast rebinning algorithm for 3D positron emission tomography using John's equation.," Inverse Probl. 15, 1047-1065 (1999).
-
(1999)
Inverse Probl.
, vol.15
, pp. 1047-1065
-
-
Defrise, M.1
Liu, X.2
-
47
-
-
35148813644
-
A fast 3D reconstruction algorithm for inverse-geometry CT based on an exact pet rebinning algorithm
-
(SPIE, San Diego, CA), Vol.,.
-
S. R. Mazin and N. J. Pelc, " A fast 3D reconstruction algorithm for inverse-geometry CT based on an exact pet rebinning algorithm.," Medical Imaging 2007: Physics of Medical Imaging (SPIE, San Diego, CA, 2007), Vol. 6510, p. 65105C-8.
-
(2007)
Medical Imaging 2007: Physics of Medical Imaging
, vol.6510
-
-
Mazin, S.R.1
Pelc, N.J.2
-
48
-
-
0021812629
-
Snr and dqe analysis of broad spectrum x-ray imaging
-
M. J. Tapiovaara and R. Wagner, " Snr and dqe analysis of broad spectrum x-ray imaging.," Phys. Med. Biol. 30 (6), 519-529 (1985).
-
(1985)
Phys. Med. Biol.
, vol.30
, Issue.6
, pp. 519-529
-
-
Tapiovaara, M.J.1
Wagner, R.2
|