메뉴 건너뛰기




Volumn 20, Issue 4, 2008, Pages 333-339

Technical Advances in Cardiovascular Imaging

Author keywords

3D echocardiography; cardiovascular imaging; ECG gated CT; MRI

Indexed keywords

ACETYLCYSTEINE; BETA ADRENERGIC RECEPTOR BLOCKING AGENT; BICARBONATE; CONTRAST MEDIUM; GLYCERYL TRINITRATE; IODINATED CONTRAST MEDIUM; NONIONIC CONTRAST MEDIUM; SODIUM CHLORIDE;

EID: 60949105163     PISSN: 10430679     EISSN: None     Source Type: Journal    
DOI: 10.1053/j.semtcvs.2008.11.015     Document Type: Article
Times cited : (5)

References (19)
  • 1
    • 0015911128 scopus 로고
    • Computerized transverse axial scanning (tomography). Part 1. Description of system
    • Hounsfield G.N. Computerized transverse axial scanning (tomography). Part 1. Description of system. Br J Radiol 46 (1973) 1016-1022
    • (1973) Br J Radiol , vol.46 , pp. 1016-1022
    • Hounsfield, G.N.1
  • 2
    • 0015789441 scopus 로고
    • Reconstruction of densities from their projections, with applications in radiological physics
    • Cormack A.M. Reconstruction of densities from their projections, with applications in radiological physics. Phys Med Biol 18 (1973) 195-207
    • (1973) Phys Med Biol , vol.18 , pp. 195-207
    • Cormack, A.M.1
  • 3
    • 0017604036 scopus 로고
    • Gated computed tomography of the human heart
    • Sagel S.S., Weiss E.S., Gillard R.G., et al. Gated computed tomography of the human heart. Invest Radiol 12 (1977) 563-566
    • (1977) Invest Radiol , vol.12 , pp. 563-566
    • Sagel, S.S.1    Weiss, E.S.2    Gillard, R.G.3
  • 4
    • 4644266911 scopus 로고    scopus 로고
    • New X-ray tube performance in computed tomography by introducing the rotating envelope tube technology
    • Schardt P., Deuringer J., Freudenberger J., et al. New X-ray tube performance in computed tomography by introducing the rotating envelope tube technology. Med Phys 31 (2004) 2699-2706
    • (2004) Med Phys , vol.31 , pp. 2699-2706
    • Schardt, P.1    Deuringer, J.2    Freudenberger, J.3
  • 5
    • 31444454089 scopus 로고    scopus 로고
    • First performance evaluation of a dual-source CT (DSCT) system
    • Flohr T.G., McCollough C.H., Bruder H., et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 16 (2006) 256-268
    • (2006) Eur Radiol , vol.16 , pp. 256-268
    • Flohr, T.G.1    McCollough, C.H.2    Bruder, H.3
  • 6
    • 43449126798 scopus 로고    scopus 로고
    • Initial evaluation of coronary images from 320-detector row computed tomography
    • Rybicki F.J., Otero H.J., Steigner M.L., et al. Initial evaluation of coronary images from 320-detector row computed tomography. Int J Cardiovasc Imaging 24 (2008) 535-546
    • (2008) Int J Cardiovasc Imaging , vol.24 , pp. 535-546
    • Rybicki, F.J.1    Otero, H.J.2    Steigner, M.L.3
  • 7
    • 33749061448 scopus 로고    scopus 로고
    • ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group. American College of Radiology, Society of Cardiovascular Computed Tomography
    • Hendel R.C., Patel M.R., Kramer C.M., et al. ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging: a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group. American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology. J Am Coll Cardiol 48 (2006) 1475-1497
    • (2006) J Am Coll Cardiol , vol.48 , pp. 1475-1497
    • Hendel, R.C.1    Patel, M.R.2    Kramer, C.M.3
  • 8
    • 54049156093 scopus 로고    scopus 로고
    • Dual-energy CT of the heart for diagnosing coronary artery stenosis and myocardial ischemia-initial experience
    • Ruzsics B., Lee H., Zwerner P.L., et al. Dual-energy CT of the heart for diagnosing coronary artery stenosis and myocardial ischemia-initial experience. Eur Radiol 18 (2008) 2414-2424
    • (2008) Eur Radiol , vol.18 , pp. 2414-2424
    • Ruzsics, B.1    Lee, H.2    Zwerner, P.L.3
  • 9
    • 40949165279 scopus 로고    scopus 로고
    • Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose
    • Earls J.P., Berman E.L., Urban B.A., et al. Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose. Radiology 246 (2008) 742-753
    • (2008) Radiology , vol.246 , pp. 742-753
    • Earls, J.P.1    Berman, E.L.2    Urban, B.A.3
  • 10
    • 49049116757 scopus 로고    scopus 로고
    • Prospective versus retrospective ECG gating for 64-detector CT of the coronary arteries: comparison of image quality and patient radiation dose
    • Shuman W.P., Branch K.R., May J.M., et al. Prospective versus retrospective ECG gating for 64-detector CT of the coronary arteries: comparison of image quality and patient radiation dose. Radiology 248 (2008) 431-437
    • (2008) Radiology , vol.248 , pp. 431-437
    • Shuman, W.P.1    Branch, K.R.2    May, J.M.3
  • 11
    • 34547121691 scopus 로고    scopus 로고
    • Strategies for reduction of radiation dose in cardiac multislice CT
    • Paul J.F., and Abada H.T. Strategies for reduction of radiation dose in cardiac multislice CT. Eur Radiol 17 (2007) 2028-2037
    • (2007) Eur Radiol , vol.17 , pp. 2028-2037
    • Paul, J.F.1    Abada, H.T.2
  • 12
    • 34948895920 scopus 로고    scopus 로고
    • Radiation dose to patients from cardiac diagnostic imaging
    • Einstein A.J., Moser K.W., Thompson R.C., et al. Radiation dose to patients from cardiac diagnostic imaging. Circulation 116 (2007) 1290-1305
    • (2007) Circulation , vol.116 , pp. 1290-1305
    • Einstein, A.J.1    Moser, K.W.2    Thompson, R.C.3
  • 14
    • 2442590642 scopus 로고    scopus 로고
    • Prevention of contrast-induced nephropathy with sodium bicarbonate: a randomized controlled trial
    • Merten G.J., Burgess W.P., Gray L.V., et al. Prevention of contrast-induced nephropathy with sodium bicarbonate: a randomized controlled trial. JAMA 291 (2004) 2328-2334
    • (2004) JAMA , vol.291 , pp. 2328-2334
    • Merten, G.J.1    Burgess, W.P.2    Gray, L.V.3
  • 15
    • 0021282475 scopus 로고
    • Measurement of flow with NMR imaging using a gradient pulse and phase difference technique
    • Bryant D.J., Payne J.A., Firmin D.N., et al. Measurement of flow with NMR imaging using a gradient pulse and phase difference technique. J Comput Assist Tomogr 8 (1984) 588-593
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 588-593
    • Bryant, D.J.1    Payne, J.A.2    Firmin, D.N.3
  • 16
    • 0023266757 scopus 로고
    • Blood flow patterns in the human aorta studied by magnetic resonance
    • Klipstein R.H., Firmin D.N., Underwood S.R., et al. Blood flow patterns in the human aorta studied by magnetic resonance. Br Heart J 58 (1987) 316-323
    • (1987) Br Heart J , vol.58 , pp. 316-323
    • Klipstein, R.H.1    Firmin, D.N.2    Underwood, S.R.3
  • 17
    • 12244274310 scopus 로고    scopus 로고
    • Time-resolved three-dimensional phase-contrast MRI
    • Markl M., Chan F.P., Alley M.T., et al. Time-resolved three-dimensional phase-contrast MRI. J Magn Reson Imaging 17 (2003) 499-506
    • (2003) J Magn Reson Imaging , vol.17 , pp. 499-506
    • Markl, M.1    Chan, F.P.2    Alley, M.T.3
  • 18
    • 37349004799 scopus 로고    scopus 로고
    • Comparison of flow patterns in ascending aortic aneurysms and volunteers using four-dimensional magnetic resonance velocity mapping
    • Hope T.A., Markl M., Wigstrom L., et al. Comparison of flow patterns in ascending aortic aneurysms and volunteers using four-dimensional magnetic resonance velocity mapping. J Magn Reson Imaging 26 (2007) 1471-1479
    • (2007) J Magn Reson Imaging , vol.26 , pp. 1471-1479
    • Hope, T.A.1    Markl, M.2    Wigstrom, L.3
  • 19
    • 23044502989 scopus 로고    scopus 로고
    • Time-resolved three-dimensional magnetic resonance velocity mapping of aortic flow in healthy volunteers and patients after valve-sparing aortic root replacement
    • Markl M., Draney M.T., Miller D.C., et al. Time-resolved three-dimensional magnetic resonance velocity mapping of aortic flow in healthy volunteers and patients after valve-sparing aortic root replacement. J Thorac Cardiovasc Surg 130 (2005) 456-463
    • (2005) J Thorac Cardiovasc Surg , vol.130 , pp. 456-463
    • Markl, M.1    Draney, M.T.2    Miller, D.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.