메뉴 건너뛰기




Volumn 14, Issue 2, 2009, Pages 197-205

Reliability of assisted indentation in measuring lumbar spinal stiffness

Author keywords

Assisted indention; Indentation; Posteroanterior compression; Reliability; Spinal stiffness

Indexed keywords

ADULT; AGE FACTORS; ANALYSIS OF VARIANCE; CHRONIC DISEASE; COHORT STUDIES; EQUIPMENT DESIGN; FEMALE; HUMANS; LOW BACK PAIN; LUMBAR VERTEBRAE; LUMBOSACRAL REGION; MALE; OBSERVER VARIATION; PHYSICAL EXAMINATION; PROBABILITY; PRONE POSITION; SEVERITY OF ILLNESS INDEX; SEX FACTORS; SPASM;

EID: 60949094512     PISSN: 1356689X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.math.2008.01.011     Document Type: Article
Times cited : (24)

References (32)
  • 3
    • 0029089706 scopus 로고
    • Intrarater reliability of lumbar accessory motion mobility testing
    • Binkley J.M., Stratford P.W., and Gill C. Intrarater reliability of lumbar accessory motion mobility testing. Phys Ther 75 (1995) 786-792
    • (1995) Phys Ther , vol.75 , pp. 786-792
    • Binkley, J.M.1    Stratford, P.W.2    Gill, C.3
  • 4
    • 0035129822 scopus 로고    scopus 로고
    • Effect of direction of applied mobilization force on the posteroanterior response in the lumbar spine
    • Caling B., and Lee M. Effect of direction of applied mobilization force on the posteroanterior response in the lumbar spine. J Manipulative Physiol Ther 24 (2001) 71-78
    • (2001) J Manipulative Physiol Ther , vol.24 , pp. 71-78
    • Caling, B.1    Lee, M.2
  • 5
    • 19944367269 scopus 로고    scopus 로고
    • A clinical prediction rule to identify patients with low back pain most likely to benefit from spinal manipulation: a validation study
    • Childs J.D., Fritz J.M., Flynn T.W., Irrgang J.J., Johnson K.K., Majkowski G.R., et al. A clinical prediction rule to identify patients with low back pain most likely to benefit from spinal manipulation: a validation study. Ann Intern Med 141 (2004) 920-928
    • (2004) Ann Intern Med , vol.141 , pp. 920-928
    • Childs, J.D.1    Fritz, J.M.2    Flynn, T.W.3    Irrgang, J.J.4    Johnson, K.K.5    Majkowski, G.R.6
  • 9
    • 33846600366 scopus 로고    scopus 로고
    • Palpation identification of spinous processes in the lumbar spine
    • Harlick J.C., Milosavljevic S., and Milburn P.D. Palpation identification of spinous processes in the lumbar spine. Man Ther 12 (2007) 56-62
    • (2007) Man Ther , vol.12 , pp. 56-62
    • Harlick, J.C.1    Milosavljevic, S.2    Milburn, P.D.3
  • 10
    • 25144514930 scopus 로고    scopus 로고
    • Preliminary development of a clinical prediction rule for determining which patients with low back pain will respond to a stabilization program
    • Hicks G.E., Fritz J.M., Delitto A., and McGill S.M. Preliminary development of a clinical prediction rule for determining which patients with low back pain will respond to a stabilization program. Arch Phys Med Rehabil 86 (2005) 1753-1762
    • (2005) Arch Phys Med Rehabil , vol.86 , pp. 1753-1762
    • Hicks, G.E.1    Fritz, J.M.2    Delitto, A.3    McGill, S.M.4
  • 11
    • 0030042706 scopus 로고    scopus 로고
    • A new technique of tissue stiffness (compliance) assessment: its reliability, accuracy and comparison with an existing method
    • Kawchuk G., and Herzog W. A new technique of tissue stiffness (compliance) assessment: its reliability, accuracy and comparison with an existing method. J Manipulative Physiol Ther 19 (1996) 13-18
    • (1996) J Manipulative Physiol Ther , vol.19 , pp. 13-18
    • Kawchuk, G.1    Herzog, W.2
  • 12
    • 0035127925 scopus 로고    scopus 로고
    • Sources of variation in spinal indentation testing: indentation site relocation, intraabdominal pressure, subject movement, muscular response, and stiffness estimate
    • Kawchuk G.N., and Fauvel O.R. Sources of variation in spinal indentation testing: indentation site relocation, intraabdominal pressure, subject movement, muscular response, and stiffness estimate. J Manipulative Physiol Ther 24 (2001) 84-91
    • (2001) J Manipulative Physiol Ther , vol.24 , pp. 84-91
    • Kawchuk, G.N.1    Fauvel, O.R.2
  • 13
    • 32044446467 scopus 로고    scopus 로고
    • The accuracy of ultrasonic indentation: a comparison of three techniques
    • Kawchuk G., Liddle T., and Fauvel R. The accuracy of ultrasonic indentation: a comparison of three techniques. J Manipulative Physiol Ther 29 (2006) 126-133
    • (2006) J Manipulative Physiol Ther , vol.29 , pp. 126-133
    • Kawchuk, G.1    Liddle, T.2    Fauvel, R.3
  • 14
    • 0031902456 scopus 로고    scopus 로고
    • The effects of high and low loading forces on measured values of lumbar stiffness
    • Latimer J., Lee M., and Adams R. The effects of high and low loading forces on measured values of lumbar stiffness. J Manipulative Physiol Ther 21 (1998) 157-163
    • (1998) J Manipulative Physiol Ther , vol.21 , pp. 157-163
    • Latimer, J.1    Lee, M.2    Adams, R.3
  • 15
    • 0030470398 scopus 로고    scopus 로고
    • An investigation of the relationship between low back pain and lumbar posteroanterior stiffness
    • Latimer J., Lee M., Adams R., and Moran C. An investigation of the relationship between low back pain and lumbar posteroanterior stiffness. J Manipulative Physiol Ther 19 (1996) 587-591
    • (1996) J Manipulative Physiol Ther , vol.19 , pp. 587-591
    • Latimer, J.1    Lee, M.2    Adams, R.3    Moran, C.4
  • 17
    • 0030038526 scopus 로고    scopus 로고
    • Evaluation of a new device for measuring responses to posteroanterior forces in a patient population, Part I: Reliability testing
    • Latimer J., Goodsell M.M., Lee M., Maher C.G., Wilkinson B.N., and Moran C.C. Evaluation of a new device for measuring responses to posteroanterior forces in a patient population, Part I: Reliability testing. Phys Ther 76 (1996) 158-165
    • (1996) Phys Ther , vol.76 , pp. 158-165
    • Latimer, J.1    Goodsell, M.M.2    Lee, M.3    Maher, C.G.4    Wilkinson, B.N.5    Moran, C.C.6
  • 18
    • 0026715779 scopus 로고
    • Load-displacement-time characteristics of the spine under posteroanterior mobilisation
    • Lee R., and Evans J. Load-displacement-time characteristics of the spine under posteroanterior mobilisation. Aust J Physiother 38 (1992) 115-123
    • (1992) Aust J Physiother , vol.38 , pp. 115-123
    • Lee, R.1    Evans, J.2
  • 19
    • 0027946601 scopus 로고
    • Posteroanterior stiffness at three locations in the lumbar spine
    • Lee M., and Liversidge K. Posteroanterior stiffness at three locations in the lumbar spine. J Manipulative Physiol Ther 17 (1994) 511-516
    • (1994) J Manipulative Physiol Ther , vol.17 , pp. 511-516
    • Lee, M.1    Liversidge, K.2
  • 20
    • 0025473355 scopus 로고
    • Measurement of stiffness during simulated spinal physiotherapy
    • Lee M., and Svensson N.L. Measurement of stiffness during simulated spinal physiotherapy. Clin Phys Physiol Meas 11 (1990) 201-207
    • (1990) Clin Phys Physiol Meas , vol.11 , pp. 201-207
    • Lee, M.1    Svensson, N.L.2
  • 21
    • 0027941158 scopus 로고
    • Reliability of pain and stiffness assessments in clinical manual lumbar spine examination
    • Maher C.G., and Adams R. Reliability of pain and stiffness assessments in clinical manual lumbar spine examination. Phys Ther 74 (1994) 801-809
    • (1994) Phys Ther , vol.74 , pp. 801-809
    • Maher, C.G.1    Adams, R.2
  • 22
    • 0029122653 scopus 로고
    • A psychophysical evaluation of manual stiffness discrimination
    • Maher C., and Adams R. A psychophysical evaluation of manual stiffness discrimination. Aust J Physiother 41 (1995) 161-167
    • (1995) Aust J Physiother , vol.41 , pp. 161-167
    • Maher, C.1    Adams, R.2
  • 23
    • 0029882697 scopus 로고    scopus 로고
    • Stiffness judgments are affected by visual occlusion
    • Maher C.G., and Adams R.D. Stiffness judgments are affected by visual occlusion. J Manipulative Physiol Ther 19 (1996) 250-256
    • (1996) J Manipulative Physiol Ther , vol.19 , pp. 250-256
    • Maher, C.G.1    Adams, R.D.2
  • 24
    • 0031904478 scopus 로고    scopus 로고
    • An investigation of the reliability and validity of posteroanterior spinal stiffness judgments using a reference-based protocol
    • Maher C.G., Latimer J., and Adams R. An investigation of the reliability and validity of posteroanterior spinal stiffness judgments using a reference-based protocol. Phys Ther 78 (1998) 829-837
    • (1998) Phys Ther , vol.78 , pp. 829-837
    • Maher, C.G.1    Latimer, J.2    Adams, R.3
  • 25
    • 0032868696 scopus 로고    scopus 로고
    • Plinth padding confounds measures of posteroanterior stiffness
    • Maher C.G., Latimer J., and Holland M.J. Plinth padding confounds measures of posteroanterior stiffness. Man Ther 14 (1999) 145-150
    • (1999) Man Ther , vol.14 , pp. 145-150
    • Maher, C.G.1    Latimer, J.2    Holland, M.J.3
  • 28
    • 0022313144 scopus 로고
    • The reliability of selected techniques in clinical arthrometrics
    • Matyas T., and Bach T.M. The reliability of selected techniques in clinical arthrometrics. Aust J Physiother 31 (1985) 175-199
    • (1985) Aust J Physiother , vol.31 , pp. 175-199
    • Matyas, T.1    Bach, T.M.2
  • 29
    • 48249153186 scopus 로고
    • Intraclass correlation: uses in assessing rater reliability
    • Shrout P.E., and Fleiss J.L. Intraclass correlation: uses in assessing rater reliability. Psychol Bull 86 (1979) 420-428
    • (1979) Psychol Bull , vol.86 , pp. 420-428
    • Shrout, P.E.1    Fleiss, J.L.2
  • 30
    • 33646236550 scopus 로고    scopus 로고
    • Manual forces applied during poster-to-anterior spinal mobilization: a review of the evidence
    • Snodgrass S.J., Rivett D.A., and Robertson V.J. Manual forces applied during poster-to-anterior spinal mobilization: a review of the evidence. J Manipulative Physiol Ther 29 (2006) 316-329
    • (2006) J Manipulative Physiol Ther , vol.29 , pp. 316-329
    • Snodgrass, S.J.1    Rivett, D.A.2    Robertson, V.J.3
  • 31
    • 0031415938 scopus 로고    scopus 로고
    • Posteroanterior stiffness in the lumbosacral spine: the correlation between adjacent vertebral levels
    • [discussion 2729-30]
    • Viner A., Lee M., and Adams R. Posteroanterior stiffness in the lumbosacral spine: the correlation between adjacent vertebral levels. Spine 22 (1997) 2724-2729 [discussion 2729-30]
    • (1997) Spine , vol.22 , pp. 2724-2729
    • Viner, A.1    Lee, M.2    Adams, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.