메뉴 건너뛰기




Volumn 157, Issue 1, 2009, Pages 80-83

Use of a robotic RNA purification protocol based on the NucliSens® easyMAG™ for real-time RT-PCR detection of hepatitis A virus in bottled water

Author keywords

Bottled water; Hepatitis A virus; NucliSens easyMAG ; Real time RT PCR; RNA extraction

Indexed keywords

SILICON DIOXIDE; VIRUS RNA;

EID: 60849117521     PISSN: 01660934     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jviromet.2008.11.022     Document Type: Article
Times cited : (32)

References (15)
  • 2
    • 46549089667 scopus 로고    scopus 로고
    • New tools for the study and direct surveillance of viral pathogens in water
    • Bosch A., Guix S., Sano D., and Pintó R.M. New tools for the study and direct surveillance of viral pathogens in water. Curr. Opin. Biotechnol. 19 (2008) 295-301
    • (2008) Curr. Opin. Biotechnol. , vol.19 , pp. 295-301
    • Bosch, A.1    Guix, S.2    Sano, D.3    Pintó, R.M.4
  • 3
    • 49049090021 scopus 로고    scopus 로고
    • Comparison of the NucliSens easyMAG and Qiagen BioRobot 9604 nucleic acid extraction systems for detection of RNA and DNA respiratory viruses on nasopharyngeal aspirate samples
    • Chan K.H., Yam W.C., Pang C.M., Chan K.M., Lam S.Y., Lo K.F., Poon L.L., and Peiris J.S.M. Comparison of the NucliSens easyMAG and Qiagen BioRobot 9604 nucleic acid extraction systems for detection of RNA and DNA respiratory viruses on nasopharyngeal aspirate samples. J. Clin. Microbiol. 46 (2008) 2195-2199
    • (2008) J. Clin. Microbiol. , vol.46 , pp. 2195-2199
    • Chan, K.H.1    Yam, W.C.2    Pang, C.M.3    Chan, K.M.4    Lam, S.Y.5    Lo, K.F.6    Poon, L.L.7    Peiris, J.S.M.8
  • 4
    • 33745152691 scopus 로고    scopus 로고
    • Development, evaluation and standardization of a real time TaqMan reverse transcription-PCR assay for quantification of hepatitis A virus in clinical and shellfish samples
    • Costafreda M.I., Bosch A., and Pinto R.M. Development, evaluation and standardization of a real time TaqMan reverse transcription-PCR assay for quantification of hepatitis A virus in clinical and shellfish samples. Appl. Environ. Microbiol. 72 (2006) 3846-3855
    • (2006) Appl. Environ. Microbiol. , vol.72 , pp. 3846-3855
    • Costafreda, M.I.1    Bosch, A.2    Pinto, R.M.3
  • 5
    • 0023263622 scopus 로고
    • Development of a plaque assay for a cytopathic, rapidly replicating isolate of hepatitis A virus
    • Cromeans T., Sobsey M.D., and Fields H.A. Development of a plaque assay for a cytopathic, rapidly replicating isolate of hepatitis A virus. J. Med. Virol. 22 (1987) 45-56
    • (1987) J. Med. Virol. , vol.22 , pp. 45-56
    • Cromeans, T.1    Sobsey, M.D.2    Fields, H.A.3
  • 6
    • 33845784820 scopus 로고    scopus 로고
    • A robotic DNA purification protocol and real-time PCR for the detection of Enterobacter sakazakii in powdered infant formulae
    • Derzelle S., and Dilasser F. A robotic DNA purification protocol and real-time PCR for the detection of Enterobacter sakazakii in powdered infant formulae. BMC Microbiol. 13 6 (2006) 100
    • (2006) BMC Microbiol. , vol.13 , Issue.6 , pp. 100
    • Derzelle, S.1    Dilasser, F.2
  • 7
    • 33645849799 scopus 로고    scopus 로고
    • Intra-laboratory validation of a concentration method adapted for the enumeration of infectious F-specific RNA coliphage, enterovirus, and hepatitis A virus from inoculated leaves of salad vegetables
    • Dubois E., Hennechart C., Deboosère N., Merle G., Legeay O., Burger C., Le Calvé M., Lombard B., Ferré V., and Traoré O. Intra-laboratory validation of a concentration method adapted for the enumeration of infectious F-specific RNA coliphage, enterovirus, and hepatitis A virus from inoculated leaves of salad vegetables. Int. J. Food Microbiol. 108 (2006) 164-171
    • (2006) Int. J. Food Microbiol. , vol.108 , pp. 164-171
    • Dubois, E.1    Hennechart, C.2    Deboosère, N.3    Merle, G.4    Legeay, O.5    Burger, C.6    Le Calvé, M.7    Lombard, B.8    Ferré, V.9    Traoré, O.10
  • 8
    • 34249083843 scopus 로고    scopus 로고
    • Detection and quantification by real-time RT-PCR of hepatitis A virus from inoculated tap waters, salad vegetables, and soft fruits: characterization of the method performances
    • Dubois E., Hennechart C., Merle G., Burger C., Hmila N., Ruelle S., Perelle S., and Ferré V. Detection and quantification by real-time RT-PCR of hepatitis A virus from inoculated tap waters, salad vegetables, and soft fruits: characterization of the method performances. Int. J. Food Microbiol. 117 (2007) 141-149
    • (2007) Int. J. Food Microbiol. , vol.117 , pp. 141-149
    • Dubois, E.1    Hennechart, C.2    Merle, G.3    Burger, C.4    Hmila, N.5    Ruelle, S.6    Perelle, S.7    Ferré, V.8
  • 9
    • 0026069630 scopus 로고
    • Antigenic and genetic variation in cytopathic hepatitis A virus variants arising during persistent infection: evidence for genetic recombination
    • Lemon S.M., Murphy P.C., Shields P.A., Ping L.H., Feinstone S.M., Cromeans T., and Jansen R.W. Antigenic and genetic variation in cytopathic hepatitis A virus variants arising during persistent infection: evidence for genetic recombination. J. Virol. 65 (1991) 2056-2065
    • (1991) J. Virol. , vol.65 , pp. 2056-2065
    • Lemon, S.M.1    Murphy, P.C.2    Shields, P.A.3    Ping, L.H.4    Feinstone, S.M.5    Cromeans, T.6    Jansen, R.W.7
  • 10
    • 33847065406 scopus 로고    scopus 로고
    • Evaluation of NucliSens easyMAG for automated nucleic acid extraction from various clinical specimens
    • Loens K., Bergs K., Ursi D., Goossens H., and Ieven M. Evaluation of NucliSens easyMAG for automated nucleic acid extraction from various clinical specimens. J. Clin. Microbiol. 45 (2007) 421-425
    • (2007) J. Clin. Microbiol. , vol.45 , pp. 421-425
    • Loens, K.1    Bergs, K.2    Ursi, D.3    Goossens, H.4    Ieven, M.5
  • 11
    • 38049076025 scopus 로고    scopus 로고
    • Evaluation of the NucliSens miniMAG RNA extraction and real-time NASBA applications for the detection of Mycoplasma pneumoniae and Chlamydophila pneumoniae in throat swabs
    • Loens K., Ursi D., Goossens H., and Ieven M. Evaluation of the NucliSens miniMAG RNA extraction and real-time NASBA applications for the detection of Mycoplasma pneumoniae and Chlamydophila pneumoniae in throat swabs. J. Microbiol. Methods 72 (2008) 217-219
    • (2008) J. Microbiol. Methods , vol.72 , pp. 217-219
    • Loens, K.1    Ursi, D.2    Goossens, H.3    Ieven, M.4
  • 12
    • 22144473001 scopus 로고    scopus 로고
    • Isolation and detection of enterovirus RNA from large-volume water samples by using the NucliSens miniMAG system and real-time nucleic acid sequence-based amplification
    • Rutjes S.A., Italiaander R., van den Berg H.H., Lodder W.J., and de Roda Husman A.M. Isolation and detection of enterovirus RNA from large-volume water samples by using the NucliSens miniMAG system and real-time nucleic acid sequence-based amplification. Appl. Environ. Microbiol. 71 (2005) 3734-3740
    • (2005) Appl. Environ. Microbiol. , vol.71 , pp. 3734-3740
    • Rutjes, S.A.1    Italiaander, R.2    van den Berg, H.H.3    Lodder, W.J.4    de Roda Husman, A.M.5
  • 13
    • 34347360835 scopus 로고    scopus 로고
    • Hepatitis A virus detection in food: current and future prospects
    • Sánchez G., Bosch A., and Pintó R.M. Hepatitis A virus detection in food: current and future prospects. Lett. Appl. Microbiol. 45 (2007) 1-5
    • (2007) Lett. Appl. Microbiol. , vol.45 , pp. 1-5
    • Sánchez, G.1    Bosch, A.2    Pintó, R.M.3
  • 14
    • 34247274198 scopus 로고    scopus 로고
    • Evaluation of the performance of the automated NucliSENS easyMAG and EasyQ systems versus the Roche AmpliPrep-AMPLICOR combination for high-throughput monitoring of human immunodeficiency virus load
    • Stevens W., Horsfield P., and Scott L.E. Evaluation of the performance of the automated NucliSENS easyMAG and EasyQ systems versus the Roche AmpliPrep-AMPLICOR combination for high-throughput monitoring of human immunodeficiency virus load. J. Clin. Microbiol. 45 (2007) 1244-1249
    • (2007) J. Clin. Microbiol. , vol.45 , pp. 1244-1249
    • Stevens, W.1    Horsfield, P.2    Scott, L.E.3
  • 15
    • 1542356381 scopus 로고    scopus 로고
    • Standardized determination of real-time PCR efficiency from a single reaction set-up
    • Erratum in: Nucleic Acids Res. (2003) 31(22), 6688
    • Tichopad A., Dilger M., Schwarz G., and Plaffl M.W. Standardized determination of real-time PCR efficiency from a single reaction set-up. Nucleic Acids Res. 31 20 (2003) e122 Erratum in: Nucleic Acids Res. (2003) 31(22), 6688
    • (2003) Nucleic Acids Res. , vol.31 , Issue.20
    • Tichopad, A.1    Dilger, M.2    Schwarz, G.3    Plaffl, M.W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.