메뉴 건너뛰기




Volumn 32, Issue SUPPL. 1, 2009, Pages

Relationship between amplitude and timing of heart sounds and endocardial acceleration

Author keywords

Atrioventricular delay; Electro mechanical delay; First heart sound; Peak endocardial acceleration; Second heart sound

Indexed keywords

ADULT; AGED; ATRIOVENTRICULAR BLOCK; CLINICAL ARTICLE; CONFERENCE PAPER; CONTROLLED STUDY; ELECTROCARDIOGRAPHY; FEMALE; HEART FUNCTION; HEART HEMODYNAMICS; HEART SOUND; HUMAN; MALE; PACEMAKER; PHONOCARDIOGRAPHY;

EID: 60849106652     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2008.02297.x     Document Type: Conference Paper
Times cited : (21)

References (16)
  • 1
    • 0014503455 scopus 로고
    • Usefulness and limitations of the rate of rise of intraventricular pressure (dP/dt) in the evaluation of myocardial contractility
    • Masson D. Usefulness and limitations of the rate of rise of intraventricular pressure (dP/dt) in the evaluation of myocardial contractility. Am J Cardiol 1969 23 : 516 527.
    • (1969) Am J Cardiol , vol.23 , pp. 516-527
    • Masson, D.1
  • 3
    • 0036461638 scopus 로고    scopus 로고
    • PEA I and PEA II based implantable haemodynamic monitor: Pre clinical studies in sheep
    • Plicchi G, Marcelli E, Parlapiano M, Bombardini T. PEA I and PEA II based implantable haemodynamic monitor: Pre clinical studies in sheep. Europace 2002 4 : 49 54.
    • (2002) Europace , vol.4 , pp. 49-54
    • Plicchi, G.1    Marcelli, E.2    Parlapiano, M.3    Bombardini, T.4
  • 4
    • 0030449672 scopus 로고    scopus 로고
    • An implantable intracardiac accelerometer for monitoring myocardial contractility. the Multicenter PEA Study Group
    • Rickards AF, Bombardini T, Corbucci G, Plicchi G. An implantable intracardiac accelerometer for monitoring myocardial contractility. The Multicenter PEA Study Group. Pacing Clin Electrophysiol 1996 19 : 2066 2071.
    • (1996) Pacing Clin Electrophysiol , vol.19 , pp. 2066-2071
    • Rickards, A.F.1    Bombardini, T.2    Corbucci, G.3    Plicchi, G.4
  • 5
    • 0022615719 scopus 로고
    • New index of cardiac contractility during stress testing with treadmill
    • Luisada A, Singhal A, Knighten V. New index of cardiac contractility during stress testing with treadmill. Acta Cardiol 1986 41 : 31 39.
    • (1986) Acta Cardiol , vol.41 , pp. 31-39
    • Luisada, A.1    Singhal, A.2    Knighten, V.3
  • 6
    • 0015748592 scopus 로고
    • On the unitary nature of cardiac vibrations
    • Luisada AA, Feigen LP, Mori K. On the unitary nature of cardiac vibrations. Jpn Heart J 1973 14 : 406 413.
    • (1973) Jpn Heart J , vol.14 , pp. 406-413
    • Luisada, A.A.1    Feigen, L.P.2    Mori, K.3
  • 7
    • 1542314951 scopus 로고
    • Hemodynamic determinants of the amplitude of the first heart sound
    • Sakamoto T, Kusukawa R, Maccanon DM, Luisada AA. Hemodynamic determinants of the amplitude of the first heart sound. Circ Res 1965 16 : 45 57.
    • (1965) Circ Res , vol.16 , pp. 45-57
    • Sakamoto, T.1    Kusukawa, R.2    MacCanon, D.M.3    Luisada, A.A.4
  • 8
    • 0018840187 scopus 로고
    • Mechanism of influence of PR interval on loudness of first heart sound
    • Leech G, Brooks N, Green-Wilkinson A, Leatham A. Mechanism of influence of PR interval on loudness of first heart sound. Br Heart J 1980 43 : 138 142.
    • (1980) Br Heart J , vol.43 , pp. 138-142
    • Leech, G.1    Brooks, N.2    Green-Wilkinson, A.3    Leatham, A.4
  • 9
    • 4244082236 scopus 로고    scopus 로고
    • Determination of the best value of peak endocardial acceleration for optimisation of the AV delay at rest in DDDR pacing. Correlation with echographic evaluation (Abstract)
    • Dupuis J, Merheb M, Victor J. Determination of the best value of peak endocardial acceleration for optimisation of the AV delay at rest in DDDR pacing. Correlation with echographic evaluation (Abstract). Europace 2000 1 (Suppl D D23.
    • (2000) Europace , vol.1 , Issue.500
    • Dupuis, J.1    Merheb, M.2    Victor, J.3
  • 10
    • 0346665532 scopus 로고    scopus 로고
    • Programming optimal atrioventricular delay in dual chamber pacing using peak endocardial acceleration:Comparison with a standard echocardiographic procedure
    • Dupuis JM, Kobeissi A, Vitali L, Gaggini G, Merheb M, Rouleau F, Leftheriotis G, et al. Programming optimal atrioventricular delay in dual chamber pacing using peak endocardial acceleration:Comparison with a standard echocardiographic procedure. Pacing Clin Electrophysiol 2003 26 : 210 213.
    • (2003) Pacing Clin Electrophysiol , vol.26 , pp. 210-213
    • Dupuis, J.M.1    Kobeissi, A.2    Vitali, L.3    Gaggini, G.4    Merheb, M.5    Rouleau, F.6    Leftheriotis, G.7
  • 11
    • 0033108072 scopus 로고    scopus 로고
    • Determination of the optimal atrioventricular delay in DDD pacing. Comparison between echo and peak endocardial acceleration measurements
    • Ritter P, Padeletti L, Gillio-Meina L, Gaggini G. Determination of the optimal atrioventricular delay in DDD pacing. Comparison between echo and peak endocardial acceleration measurements. Europace 1999 1 : 126 130.
    • (1999) Europace , vol.1 , pp. 126-130
    • Ritter, P.1    Padeletti, L.2    Gillio-Meina, L.3    Gaggini, G.4
  • 12
    • 0017177388 scopus 로고
    • Hemodynamic correlates of the normal aortic valve echogram. a study of sound, flow, and motion
    • Laniado S, Yellin E, Terdiman R, Meytes I, Stadler J. Hemodynamic correlates of the normal aortic valve echogram. A study of sound, flow, and motion. Circulation 1976 54 : 729 737.
    • (1976) Circulation , vol.54 , pp. 729-737
    • Laniado, S.1    Yellin, E.2    Terdiman, R.3    Meytes, I.4    Stadler, J.5
  • 13
    • 0014850914 scopus 로고
    • Influence of the timing of atrial systole on mitral valve closure and on the first heart sound in man
    • Shah PM, Kramer DH, Gramiak R. Influence of the timing of atrial systole on mitral valve closure and on the first heart sound in man. Am J Cardiol 1970 26 : 231 237.
    • (1970) Am J Cardiol , vol.26 , pp. 231-237
    • Shah, P.M.1    Kramer, D.H.2    Gramiak, R.3
  • 15
    • 0016139143 scopus 로고
    • Changing views on the mechanism of the first and second heart sounds
    • Luisada AA, MacCanon DM, Kumar S, Feigen LP. Changing views on the mechanism of the first and second heart sounds. Am Heart J 1974 88 : 503 514.
    • (1974) Am Heart J , vol.88 , pp. 503-514
    • Luisada, A.A.1    MacCanon, D.M.2    Kumar, S.3    Feigen, L.P.4
  • 16
    • 0018163068 scopus 로고
    • Second heart sound: A phono-echocardiographic correlation in 20 cardiac patients
    • Prakash R. Second heart sound: A phono-echocardiographic correlation in 20 cardiac patients. J Am Geriatr Soc 1978 26 : 372 374.
    • (1978) J Am Geriatr Soc , vol.26 , pp. 372-374
    • Prakash, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.