Volumn 35, Issue 3, 2009, Pages 489-492

High defibrillation threshold in patients with implantable defibrillator: how effective is the subcutaneous finger lead?

Author keywords

Defibrillation threshold; ICD; Ventricular arrhythmia

Indexed keywords

ADULT; AGED; ARTICLE; BIOMEDICAL ENGINEERING; DEFIBRILLATOR; FEMALE; FINGER; HEART VENTRICLE FIBRILLATION; HUMAN; MAJOR CLINICAL STUDY; MALE; PACEMAKER ELECTRODE; PATIENT SAFETY; PRIORITY JOURNAL; SUBCUTANEOUS TISSUE;

EID: 60849084436     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejcts.2008.10.021     Document Type: Article
Times cited : (19)

References (18)
  • 1
    • 9844224486 scopus 로고    scopus 로고
    • A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias
    • for the Antiarrhythmics versus Implantable Defibrillator (AVID) Investigators
    • Zipes D.P., Wyse D.G., Friedman P.L., Epstein A.E., Hallstrom A.P., Greene H.L., Schron E.B., Domanski M., and for the Antiarrhythmics versus Implantable Defibrillator (AVID) Investigators. A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias. N Engl J Med 337 (1997) 1576-1583
    • (1997) N Engl J Med , vol.337 , pp. 1576-1583
    • Zipes, D.P.1    Wyse, D.G.2    Friedman, P.L.3    Epstein, A.E.4    Hallstrom, A.P.5    Greene, H.L.6    Schron, E.B.7    Domanski, M.8
  • 4
    • 0034073329 scopus 로고    scopus 로고
    • Factors affecting the frequency of subcutaneous lead usage in implantable defibrillators
    • Trusty J.M., Hayes D.L., Stanton M.S., and Friedman P.A. Factors affecting the frequency of subcutaneous lead usage in implantable defibrillators. Pacing Clin Electrophysiol 23 (2000) 842-846
    • (2000) Pacing Clin Electrophysiol , vol.23 , pp. 842-846
    • Trusty, J.M.1    Hayes, D.L.2    Stanton, M.S.3    Friedman, P.A.4
  • 7
    • 0037711837 scopus 로고    scopus 로고
    • Prospective randomized comparison of 65%/65% versus 42%/42% tilt biphasic waveform on defibrillation threshold in humans
    • Shepard R.K., DeGroot P.J., Pacifico A., Wood M.A., and Ellenbogen K.A. Prospective randomized comparison of 65%/65% versus 42%/42% tilt biphasic waveform on defibrillation threshold in humans. J Interv Card Electrophysiol 8 (2003) 221-225
    • (2003) J Interv Card Electrophysiol , vol.8 , pp. 221-225
    • Shepard, R.K.1    DeGroot, P.J.2    Pacifico, A.3    Wood, M.A.4    Ellenbogen, K.A.5
  • 10
    • 34250645232 scopus 로고    scopus 로고
    • Habitual cocaine use is associated with high defibrillation threshold during ICD implantation
    • Chen J., Naseem R.H., Obel O., and Joglar J.A. Habitual cocaine use is associated with high defibrillation threshold during ICD implantation. J Cardiovasc Electrophysiol 18 (2007) 722-725
    • (2007) J Cardiovasc Electrophysiol , vol.18 , pp. 722-725
    • Chen, J.1    Naseem, R.H.2    Obel, O.3    Joglar, J.A.4
  • 11
    • 0036828396 scopus 로고    scopus 로고
    • Halothane, isoflurane, and fentanyl increase the minimally effective defibrillation threshold of an implantable cardioverter defibrillator: first report in humans
    • Weinbroun A.A., Glick A., Copperman Y., Yashar T., Rudick V., and Flaishon R. Halothane, isoflurane, and fentanyl increase the minimally effective defibrillation threshold of an implantable cardioverter defibrillator: first report in humans. Anesth Analg 95 (2002) 1147-1153
    • (2002) Anesth Analg , vol.95 , pp. 1147-1153
    • Weinbroun, A.A.1    Glick, A.2    Copperman, Y.3    Yashar, T.4    Rudick, V.5    Flaishon, R.6
  • 12
    • 2342597245 scopus 로고    scopus 로고
    • Submuscular versus subcutaneous pectoral implantation of cardioverter defibrillators: effect on high voltage pathway impedance and defibrillation efficacy
    • Iskos D., Lock K., Lurie K.G., Fahy G.J., Petersen-Stejskal S., and Benditt D.G. Submuscular versus subcutaneous pectoral implantation of cardioverter defibrillators: effect on high voltage pathway impedance and defibrillation efficacy. J Interv Card Electrophysiol 2 (1998) 47-52
    • (1998) J Interv Card Electrophysiol , vol.2 , pp. 47-52
    • Iskos, D.1    Lock, K.2    Lurie, K.G.3    Fahy, G.J.4    Petersen-Stejskal, S.5    Benditt, D.G.6
  • 13
    • 0034834932 scopus 로고    scopus 로고
    • Bidirectional defibrillation using implantable defibrillators: a prospective randomized comparison between pectoral and abdominal active generators
    • Sandstedt B., Kennergren C., and Edvardsson N. Bidirectional defibrillation using implantable defibrillators: a prospective randomized comparison between pectoral and abdominal active generators. Pacing Clin Electrophysiol 24 (2001) 1343-1353
    • (2001) Pacing Clin Electrophysiol , vol.24 , pp. 1343-1353
    • Sandstedt, B.1    Kennergren, C.2    Edvardsson, N.3
  • 17
    • 0034881409 scopus 로고    scopus 로고
    • Defibrillation efficacy comparing a subcutaneous array electrode versus an "active can" implantable cardioverter defibrillator and a subcutaneous array electrode in addition to an "active can" implantable cardioverter defibrillator: results from active can versus array trials I and II
    • Gradaus R., Block M., Seidl K., Brunn J., Isgro F., Hammel D., Hauer B., Breithardt G., and Bocker D. Defibrillation efficacy comparing a subcutaneous array electrode versus an "active can" implantable cardioverter defibrillator and a subcutaneous array electrode in addition to an "active can" implantable cardioverter defibrillator: results from active can versus array trials I and II. J Cardiovasc Electrophysiol 12 (2001) 921-927
    • (2001) J Cardiovasc Electrophysiol , vol.12 , pp. 921-927
    • Gradaus, R.1    Block, M.2    Seidl, K.3    Brunn, J.4    Isgro, F.5    Hammel, D.6    Hauer, B.7    Breithardt, G.8    Bocker, D.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.