메뉴 건너뛰기




Volumn 33, Issue 18, 2008, Pages

Correlation between centrally versus peripherally transduced venous pressure in prone patients undergoing posterior spine surgery

Author keywords

Central and peripheral venous pressure; Monitoring; Prone position; Spine surgery

Indexed keywords

ADULT; AGED; ARTICLE; BODY POSTURE; CENTRAL VENOUS PRESSURE; CLINICAL ARTICLE; CORRELATION ANALYSIS; FLUID FLOW; HUMAN; OBSERVATIONAL STUDY; PATIENT MONITORING; PERIPHERAL VENOUS PRESSURE; PRESSURE MEASUREMENT; PRIORITY JOURNAL; SPINE SURGERY; SURGICAL PATIENT; VALIDITY; VENOUS PRESSURE; BLOOD PRESSURE MEASUREMENT; CATHETERIZATION; CLINICAL TRIAL; COMPARATIVE STUDY; FEMALE; HAND; MALE; METHODOLOGY; MIDDLE AGED; NEUROSURGERY; PHYSIOLOGY; PROSPECTIVE STUDY; VASCULARIZATION;

EID: 60549106720     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/BRS.0b013e31817c6c2f     Document Type: Article
Times cited : (15)

References (16)
  • 1
    • 31744438011 scopus 로고    scopus 로고
    • Functional hemodynamic monitoring
    • Pinsky MR, Payen D. Functional hemodynamic monitoring. Crit Care 2005;9:566-72.
    • (2005) Crit Care , vol.9 , pp. 566-572
    • Pinsky, M.R.1    Payen, D.2
  • 2
    • 0029134869 scopus 로고
    • Delayed tension pneumothorax complicating central venous catheterization and positive pressure ventilation
    • Plewa MC, Ledrick D, Sferra JJ. Delayed tension pneumothorax complicating central venous catheterization and positive pressure ventilation. Am J Emerg Med 1995;13:532-5.
    • (1995) Am J Emerg Med , vol.13 , pp. 532-535
    • Plewa, M.C.1    Ledrick, D.2    Sferra, J.J.3
  • 3
    • 0036840811 scopus 로고    scopus 로고
    • A review of risk factors for catheter-related bloodstream infection caused by percutaneously inserted, noncuffed central venous catheters: Implications for preventive strategies
    • Safdar N, Kluger DM, Maki DG. A review of risk factors for catheter-related bloodstream infection caused by percutaneously inserted, noncuffed central venous catheters: implications for preventive strategies. Medicine 2002;81:466-79.
    • (2002) Medicine , vol.81 , pp. 466-479
    • Safdar, N.1    Kluger, D.M.2    Maki, D.G.3
  • 4
    • 2942541223 scopus 로고    scopus 로고
    • Arterial misplacement of large-caliber cannulas during jugular vein catheterization: Case for surgical management
    • Shah PM, Babu SC, Goyal A, et al. Arterial misplacement of large-caliber cannulas during jugular vein catheterization: case for surgical management. ] Am Coll Surg 2004;198:939-44.
    • (2004) Am Coll Surg , vol.198 , pp. 939-944
    • Shah, P.M.1    Babu, S.C.2    Goyal, A.3
  • 5
    • 33645051233 scopus 로고    scopus 로고
    • Correlation of peripheral venous pressure and central venous pressure in kidney recipients
    • Hadimioglu N, Ertug Z, Yegin A, et al. Correlation of peripheral venous pressure and central venous pressure in kidney recipients. Transplant Proc 2006;38:440-2.
    • (2006) Transplant Proc , vol.38 , pp. 440-442
    • Hadimioglu, N.1    Ertug, Z.2    Yegin, A.3
  • 6
    • 0035160373 scopus 로고    scopus 로고
    • Peripheral venous pressure as a hemodynamic variable in neurosurgical patients
    • Munis JR, Bhatia S, Lozada LJ. Peripheral venous pressure as a hemodynamic variable in neurosurgical patients. Anesth Analg 2001;92:172-9.
    • (2001) Anesth Analg , vol.92 , pp. 172-179
    • Munis, J.R.1    Bhatia, S.2    Lozada, L.J.3
  • 7
    • 0035111694 scopus 로고    scopus 로고
    • Correlation of peripheral venous pressure and central venous pressure in surgical patients
    • Amar D, Melendez JA, Zhang H, et al. Correlation of peripheral venous pressure and central venous pressure in surgical patients. J Cardiothorac Vasc Anesth 2001;15:40-3.
    • (2001) J Cardiothorac Vasc Anesth , vol.15 , pp. 40-43
    • Amar, D.1    Melendez, J.A.2    Zhang, H.3
  • 8
    • 35448988856 scopus 로고    scopus 로고
    • Can peripheral venous pressure be an alternative to central venous pressure during right hepatectomy in living donors?
    • Choi SJ, Gwak MS, Ko JS, et al. Can peripheral venous pressure be an alternative to central venous pressure during right hepatectomy in living donors? Liver Transpl 2007;13:1414-21.
    • (2007) Liver Transpl , vol.13 , pp. 1414-1421
    • Choi, S.J.1    Gwak, M.S.2    Ko, J.S.3
  • 9
    • 16644383143 scopus 로고    scopus 로고
    • Relationship between peripheral and central venous pressures in different patient positions, catheter sizes, and. insertion sites
    • Tugrul M, Camci E, Pembeci K, et al. Relationship between peripheral and central venous pressures in different patient positions, catheter sizes, and. insertion sites. J Cardiothorac Vasc Anesth 2004;18:446-50.
    • (2004) J Cardiothorac Vasc Anesth , vol.18 , pp. 446-450
    • Tugrul, M.1    Camci, E.2    Pembeci, K.3
  • 10
    • 33744819988 scopus 로고    scopus 로고
    • Effect of prone positioning systems on hemodynamic and cardiac function during lumbar spine surgery: An echocardiographic study
    • Dharmavaram S, Jellish WS, Nockels RP, et al. Effect of prone positioning systems on hemodynamic and cardiac function during lumbar spine surgery: an echocardiographic study. Spine 2006;31:1388-94.
    • (2006) Spine , vol.31 , pp. 1388-1394
    • Dharmavaram, S.1    Jellish, W.S.2    Nockels, R.P.3
  • 11
    • 0029790504 scopus 로고    scopus 로고
    • The effect of four different surgical prone positions on cardiovascular parameters in healthy volunteers
    • Wadsworth R, Anderton JM, Vohra A. The effect of four different surgical prone positions on cardiovascular parameters in healthy volunteers. Anaesthesia 1996;51:819-22.
    • (1996) Anaesthesia , vol.51 , pp. 819-822
    • Wadsworth, R.1    Anderton, J.M.2    Vohra, A.3
  • 12
    • 0025786723 scopus 로고
    • Hemodynamic effect of the prone position during anesthesia
    • Yokoyama M, Ueda W, Hirakawa M, et al. Hemodynamic effect of the prone position during anesthesia. Acta Anaesthesiol Scand 1991;35:741-4.
    • (1991) Acta Anaesthesiol Scand , vol.35 , pp. 741-744
    • Yokoyama, M.1    Ueda, W.2    Hirakawa, M.3
  • 13
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 14
    • 0000743253 scopus 로고
    • The effect of positive and negative intra-thoracic pressure on peripheral venous pressure in man
    • Holt JP. The effect of positive and negative intra-thoracic pressure on peripheral venous pressure in man. Am J Physiol 1943;139:208-11.
    • (1943) Am J Physiol , vol.139 , pp. 208-211
    • Holt, J.P.1
  • 15
    • 17044386356 scopus 로고    scopus 로고
    • Effect of catheter site on the agreement of peripheral and central venous pressure measurements in neurosurgical patients
    • Sahin A, Salman MA, Salman AE, et al. Effect of catheter site on the agreement of peripheral and central venous pressure measurements in neurosurgical patients. J Clin Anesth 2005;17:348-52.
    • (2005) J Clin Anesth , vol.17 , pp. 348-352
    • Sahin, A.1    Salman, M.A.2    Salman, A.E.3
  • 16
    • 23044509077 scopus 로고    scopus 로고
    • Measurement of central venous pressure from a peripheral intravenous catheter in the lower extremity
    • Cox P, Johnson JO, Tobias JD. Measurement of central venous pressure from a peripheral intravenous catheter in the lower extremity. South Med J 2005;98:698-702.
    • (2005) South Med J , vol.98 , pp. 698-702
    • Cox, P.1    Johnson, J.O.2    Tobias, J.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.