메뉴 건너뛰기




Volumn 61, Issue 2, 2009, Pages 372-380

Whole-brain single-shot STEAM DTI at 4 tesla utilizing transverse coherences for enhanced SNR

Author keywords

Diffusion tensor; Extended phase graphs; Stimulated echoes; Variable flip angles

Indexed keywords

DIFFUSION; DIFFUSION TENSOR IMAGING; MAGNETIC FIELDS; MAGNETIC RESONANCE IMAGING; STEAM; TENSORS;

EID: 60549105032     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21853     Document Type: Article
Times cited : (6)

References (19)
  • 1
    • 33751096767 scopus 로고    scopus 로고
    • Probabilistic diffusion tractography with multiple fibre orientations: What can we gain?
    • Behrens TEJ, Berg HJ, Jbabdi S, Rushworth MFS, Woolrich MW. Probabilistic diffusion tractography with multiple fibre orientations: what can we gain? Neurolmage 2007;34:144-155.
    • (2007) Neurolmage , vol.34 , pp. 144-155
    • Behrens, T.E.J.1    Berg, H.J.2    Jbabdi, S.3    Rushworth, M.F.S.4    Woolrich, M.W.5
  • 3
    • 0033762725 scopus 로고    scopus 로고
    • Rapid isotropic diffusion mapping without susceptibility artifacts: Whole brain studies using diffusion-weighted single-shot STEAM MR imaging
    • Nolte UG, Finsterbusch J, Frahm J. Rapid isotropic diffusion mapping without susceptibility artifacts: whole brain studies using diffusion-weighted single-shot STEAM MR imaging. Magn Reson Med 2000;44:731-736.
    • (2000) Magn Reson Med , vol.44 , pp. 731-736
    • Nolte, U.G.1    Finsterbusch, J.2    Frahm, J.3
  • 4
    • 0036184578 scopus 로고    scopus 로고
    • Half Fourier single-shot STEAM MRI
    • Finsterbusch J, Frahm J. Half Fourier single-shot STEAM MRI. Magn Reson Med 2002; 47:611-615.
    • (2002) Magn Reson Med , vol.47 , pp. 611-615
    • Finsterbusch, J.1    Frahm, J.2
  • 5
    • 22744451920 scopus 로고    scopus 로고
    • Diffusion tensor imaging using partial Fourier STEAM MRI with projection onto convex subsets reconstruction
    • Rieseberg S, Merboldt KD, Küntzel M, Frahm J. Diffusion tensor imaging using partial Fourier STEAM MRI with projection onto convex subsets reconstruction. Magn Reson Med 2005;54:486-490.
    • (2005) Magn Reson Med , vol.54 , pp. 486-490
    • Rieseberg, S.1    Merboldt, K.D.2    Küntzel, M.3    Frahm, J.4
  • 7
    • 84985848260 scopus 로고
    • Echoes-how to generate, recognize, use or avoid them in MR-imaging sequences: Part 1
    • Hennig J. Echoes-how to generate, recognize, use or avoid them in MR-imaging sequences: part 1. Concepts Magn Reson 1991;3:125-143.
    • (1991) Concepts Magn Reson , vol.3 , pp. 125-143
    • Hennig, J.1
  • 8
    • 84985793319 scopus 로고
    • Echoes-how to generate, recognize, use or avoid them in MR-imaging sequences: Part 2
    • Hennig J. Echoes-how to generate, recognize, use or avoid them in MR-imaging sequences: part 2. Concepts Magn Reson 1991;3:179-192.
    • (1991) Concepts Magn Reson , vol.3 , pp. 179-192
    • Hennig, J.1
  • 9
    • 0033472075 scopus 로고    scopus 로고
    • A pictorial description of steady-states in rapid magnetic resonance imaging
    • Scheffler K. A pictorial description of steady-states in rapid magnetic resonance imaging. Concepts Magn Reson 1999;11:291-304.
    • (1999) Concepts Magn Reson , vol.11 , pp. 291-304
    • Scheffler, K.1
  • 10
    • 0030090158 scopus 로고    scopus 로고
    • On the stationary states in gradient echo imaging
    • Sobol W, Gauntt D. On the stationary states in gradient echo imaging. J Magn Reson Imaging 1996;6:384-398.
    • (1996) J Magn Reson Imaging , vol.6 , pp. 384-398
    • Sobol, W.1    Gauntt, D.2
  • 11
    • 33749176780 scopus 로고    scopus 로고
    • Stöcker T, Shah NJ. MP-SAGE: a new MP-RAGE sequence with enhanced SNR & CNR for brain imaging utilising square-spiral phase encoding and variable flip angles. Magn Reson Med 2006;56:824-834.
    • Stöcker T, Shah NJ. MP-SAGE: a new MP-RAGE sequence with enhanced SNR & CNR for brain imaging utilising square-spiral phase encoding and variable flip angles. Magn Reson Med 2006;56:824-834.
  • 12
    • 60549113676 scopus 로고    scopus 로고
    • SPLICE: Sub-second diffusion-sensitive mr imaging using a modified fast spin-echo acquisition mode
    • Schick F. SPLICE: sub-second diffusion-sensitive mr imaging using a modified fast spin-echo acquisition mode. Magn Reson Med 2006;56:824-834.
    • (2006) Magn Reson Med , vol.56 , pp. 824-834
    • Schick, F.1
  • 13
    • 0027092710 scopus 로고
    • Shaping the signal response during the approach to steady state in three-dimensional magnetization-prepared rapid gradient-echo imaging using variable flip angles
    • Mugler J III, Epstein F, Brookman J. Shaping the signal response during the approach to steady state in three-dimensional magnetization-prepared rapid gradient-echo imaging using variable flip angles. Magn Reson Med 1992;28:165-185.
    • (1992) Magn Reson Med , vol.28 , pp. 165-185
    • Mugler III, J.1    Epstein, F.2    Brookman, J.3
  • 17
    • 0030726766 scopus 로고    scopus 로고
    • Signal-to-noise measurements in magnitude images from NMR phased arrays
    • Constantinides CD, Atalar E, McVeigh ER. Signal-to-noise measurements in magnitude images from NMR phased arrays. Magn Reson Med 1997;38:852-857.
    • (1997) Magn Reson Med , vol.38 , pp. 852-857
    • Constantinides, C.D.1    Atalar, E.2    McVeigh, E.R.3
  • 18
    • 0037229177 scopus 로고    scopus 로고
    • Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo
    • Reese TG, Heid O, Weisskoff RM, Wedeen VJ. Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo. Magn Reson Med 2003;49:177-182.
    • (2003) Magn Reson Med , vol.49 , pp. 177-182
    • Reese, T.G.1    Heid, O.2    Weisskoff, R.M.3    Wedeen, V.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.