-
1
-
-
0038714531
-
Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermia
-
Dewhirst M.W., Viglianti B.L., Lora-Michiels M., Hanson M., and Hoopes P.J. Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermia. Int. J. Hyperther. 19 3 (2003) 267-294
-
(2003)
Int. J. Hyperther.
, vol.19
, Issue.3
, pp. 267-294
-
-
Dewhirst, M.W.1
Viglianti, B.L.2
Lora-Michiels, M.3
Hanson, M.4
Hoopes, P.J.5
-
2
-
-
37549065928
-
Hyperthermia induces differentiation without apoptosis in permissive temperatures in human erythro leukaemia cells
-
Sharif-Khatibi L., Kariminia A., Khoei S., and Goliaei B. Hyperthermia induces differentiation without apoptosis in permissive temperatures in human erythro leukaemia cells. Int. J. Hyperther. 23 8 (2007) 645-655
-
(2007)
Int. J. Hyperther.
, vol.23
, Issue.8
, pp. 645-655
-
-
Sharif-Khatibi, L.1
Kariminia, A.2
Khoei, S.3
Goliaei, B.4
-
3
-
-
1842525216
-
Introduction: radiosensitization by hyperthermia
-
Roti Roti J.L. Introduction: radiosensitization by hyperthermia. Int. J. Hyperther. 20 2 (2004) 109-114
-
(2004)
Int. J. Hyperther.
, vol.20
, Issue.2
, pp. 109-114
-
-
Roti Roti, J.L.1
-
5
-
-
0036846223
-
Optimization of electromagnetic phased arrays for hyperthermia via magnetic resonance temperature estimation
-
Kowalski M.E., Behnia B., Webb A.G., and Jin J.-M. Optimization of electromagnetic phased arrays for hyperthermia via magnetic resonance temperature estimation. IEEE Trans. Biomed. Eng. 49 11 (2002) 1229-1241
-
(2002)
IEEE Trans. Biomed. Eng.
, vol.49
, Issue.11
, pp. 1229-1241
-
-
Kowalski, M.E.1
Behnia, B.2
Webb, A.G.3
Jin, J.-M.4
-
7
-
-
60549093789
-
-
H.Y. Yang, H.-Z. Wang, Ultrasonic computed tomography used in non-invasive temperature measuring, engineering in medicine and biology society, in: Proceedings of the Annual International Conference of the IEEE, 1 (4-7) (1998) 477-478.
-
H.Y. Yang, H.-Z. Wang, Ultrasonic computed tomography used in non-invasive temperature measuring, engineering in medicine and biology society, in: Proceedings of the Annual International Conference of the IEEE, vol. 1 (4-7) (1998) 477-478.
-
-
-
-
8
-
-
9444254722
-
Ultrasonic computerized tomography (CT) for temperature measurements with limited projection data based on extrapolated filtered back projection (FBP) method
-
Zhu N., Jiang Y., and Kato S. Ultrasonic computerized tomography (CT) for temperature measurements with limited projection data based on extrapolated filtered back projection (FBP) method. Energy 30 2-4 (2005) 509-522
-
(2005)
Energy
, vol.30
, Issue.2-4
, pp. 509-522
-
-
Zhu, N.1
Jiang, Y.2
Kato, S.3
-
9
-
-
0034129105
-
Scanning thermoacoustic tomography in biological tissue
-
Ku G., and Wang L.V. Scanning thermoacoustic tomography in biological tissue. Am. Assoc. Phys. Med., Med. Phys. 5 27 (2000) 1195-1202
-
(2000)
Am. Assoc. Phys. Med., Med. Phys.
, vol.5
, Issue.27
, pp. 1195-1202
-
-
Ku, G.1
Wang, L.V.2
-
10
-
-
0031861450
-
Non invasive microwave radiometry thermometry
-
Leroy Y., Bocquet B., and Mamouni A. Non invasive microwave radiometry thermometry. Physiol. Meas. 19 (1998) 127-148
-
(1998)
Physiol. Meas.
, vol.19
, pp. 127-148
-
-
Leroy, Y.1
Bocquet, B.2
Mamouni, A.3
-
11
-
-
0025566001
-
Development of an electrical impedance tomography system for noninvasive temperature monitoring of hyperthermia treatments
-
Blad B., Bertenstom L., and Persson B.R. Development of an electrical impedance tomography system for noninvasive temperature monitoring of hyperthermia treatments. Adv. Exp. Med. Biol. 267 (1990) 235-243
-
(1990)
Adv. Exp. Med. Biol.
, vol.267
, pp. 235-243
-
-
Blad, B.1
Bertenstom, L.2
Persson, B.R.3
-
12
-
-
28444491096
-
Non-invasive estimation of hyperthermia temperatures with ultrasound
-
Arthur R.M., Straube W.L., Trobaugh J.W., and Moros E.G. Non-invasive estimation of hyperthermia temperatures with ultrasound. Int. J. Hyperther. 21 6 (2005) 589-600
-
(2005)
Int. J. Hyperther.
, vol.21
, Issue.6
, pp. 589-600
-
-
Arthur, R.M.1
Straube, W.L.2
Trobaugh, J.W.3
Moros, E.G.4
-
13
-
-
0030792572
-
Dependence of ultrasonic attenuation and absorption in dog soft tissues on temperature and thermal dose
-
Damianou C.A., Sanghvi N.T., Fry F.J., and Maass-Moreno R. Dependence of ultrasonic attenuation and absorption in dog soft tissues on temperature and thermal dose. J. Acoust. Soc. Am. 102 (1997) 628-634
-
(1997)
J. Acoust. Soc. Am.
, vol.102
, pp. 628-634
-
-
Damianou, C.A.1
Sanghvi, N.T.2
Fry, F.J.3
Maass-Moreno, R.4
-
15
-
-
0037280051
-
The changes in acoustic attenuation due to in vitro heating
-
Clarke R.L., Bush N.L., and Ter Haar G.R. The changes in acoustic attenuation due to in vitro heating. Ultrasound Med. Biol. 29 (2003) 127-135
-
(2003)
Ultrasound Med. Biol.
, vol.29
, pp. 127-135
-
-
Clarke, R.L.1
Bush, N.L.2
Ter Haar, G.R.3
-
16
-
-
0032412292
-
Differential attenuation imaging for the characterization of high intensity focused ultrasound lesions
-
Ribault M., Chapelon J., Cathignol D., and Gelet A. Differential attenuation imaging for the characterization of high intensity focused ultrasound lesions. Ultrasonic Imaging 20 (1998) 160-177
-
(1998)
Ultrasonic Imaging
, vol.20
, pp. 160-177
-
-
Ribault, M.1
Chapelon, J.2
Cathignol, D.3
Gelet, A.4
-
17
-
-
2942648071
-
Temperature dependence of ultrasonic propagation speed and attenuation in excised canine liver tissue measured using transmitted and reflected pulses
-
Techavipoo U., Varghese T., Chen Q., Stiles T.A., Zagzebski J.A., and Frank G.R. Temperature dependence of ultrasonic propagation speed and attenuation in excised canine liver tissue measured using transmitted and reflected pulses. J. Acoust. Soc. Am. 115 (2004) 2859-2865
-
(2004)
J. Acoust. Soc. Am.
, vol.115
, pp. 2859-2865
-
-
Techavipoo, U.1
Varghese, T.2
Chen, Q.3
Stiles, T.A.4
Zagzebski, J.A.5
Frank, G.R.6
-
18
-
-
0015323588
-
An analysis of lesion development in the brain and in plastics by high intensity focused ultrasound at low-megahertz frequencies
-
Robinson T.C., and Lele P.P. An analysis of lesion development in the brain and in plastics by high intensity focused ultrasound at low-megahertz frequencies. J. Acoust. Soc. Am. 5 (1972) 1333-1351
-
(1972)
J. Acoust. Soc. Am.
, vol.5
, pp. 1333-1351
-
-
Robinson, T.C.1
Lele, P.P.2
-
19
-
-
0036771563
-
Attenuation coefficient and propagation speed estimates of rat and pig intercostals tissue as a function of temperature
-
Towa R.T., Miller R.J., Frizzell L.A., Zachary J.F., and O'Brien Jr. W.D. Attenuation coefficient and propagation speed estimates of rat and pig intercostals tissue as a function of temperature. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 49 (2002) 1411-1420
-
(2002)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.49
, pp. 1411-1420
-
-
Towa, R.T.1
Miller, R.J.2
Frizzell, L.A.3
Zachary, J.F.4
O'Brien Jr., W.D.5
-
20
-
-
0029798475
-
Noninvasive temperature estimation in tissue via ultrasound echo-shifts. Part I. Analytical model
-
Maass-Moreno R., and Damianou C.A. Noninvasive temperature estimation in tissue via ultrasound echo-shifts. Part I. Analytical model. J. Acoust. Soc. Am. 100 4 (1996) 2514-2521
-
(1996)
J. Acoust. Soc. Am.
, vol.100
, Issue.4
, pp. 2514-2521
-
-
Maass-Moreno, R.1
Damianou, C.A.2
-
21
-
-
0029794863
-
Noninvasive temperature estimation in tissue via ultrasound echo-shifts. Part II. In vitro study
-
Maass-Moreno R., Damianou C.A., and Sanghvi N.T. Noninvasive temperature estimation in tissue via ultrasound echo-shifts. Part II. In vitro study. J. Acoust. Soc. Am. 100 4 (1996) 2522-2530
-
(1996)
J. Acoust. Soc. Am.
, vol.100
, Issue.4
, pp. 2522-2530
-
-
Maass-Moreno, R.1
Damianou, C.A.2
Sanghvi, N.T.3
-
22
-
-
0029347489
-
Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound
-
Seip R., and Ebbini E.S. Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound. IEEE Trans. Biomed. Eng. 42 8 (1995) 828-839
-
(1995)
IEEE Trans. Biomed. Eng.
, vol.42
, Issue.8
, pp. 828-839
-
-
Seip, R.1
Ebbini, E.S.2
-
23
-
-
34547907815
-
Non-invasive temperature estimation in oncology hyperthermia by using phase changes in pulse-echo ultrasonic signals
-
Vázquez M., Ramos A., Vera A., and Leija L. Non-invasive temperature estimation in oncology hyperthermia by using phase changes in pulse-echo ultrasonic signals. Jpn. Appl. Phys. 45 (2006) 7991-7998
-
(2006)
Jpn. Appl. Phys.
, vol.45
, pp. 7991-7998
-
-
Vázquez, M.1
Ramos, A.2
Vera, A.3
Leija, L.4
-
24
-
-
0031150155
-
Performance of time delay estimation methods for small time shifts in ultrasonic signals
-
De Korte C.L., Van Der Steen A.F.W., Dijkman B.H.J., and Lancée C.T. Performance of time delay estimation methods for small time shifts in ultrasonic signals. Ultrasonics 35 (1997) 263-274
-
(1997)
Ultrasonics
, vol.35
, pp. 263-274
-
-
De Korte, C.L.1
Van Der Steen, A.F.W.2
Dijkman, B.H.J.3
Lancée, C.T.4
-
25
-
-
0036815626
-
Fundamental limitations of noninvasive temperature imaging by means of ultrasound echo strain estimation
-
Miller N.R., Bamber J.C., and Meaney P.M. Fundamental limitations of noninvasive temperature imaging by means of ultrasound echo strain estimation. Ultrasound Med. Biol. 28 10 (2002) 1319-1333
-
(2002)
Ultrasound Med. Biol.
, vol.28
, Issue.10
, pp. 1319-1333
-
-
Miller, N.R.1
Bamber, J.C.2
Meaney, P.M.3
-
26
-
-
0031365556
-
Quantitative analysis and applications of non-invasive temperature estimation using diagnostic ultrasound
-
Simon C., VanBaren P., and Ebbini E. Quantitative analysis and applications of non-invasive temperature estimation using diagnostic ultrasound. IEEE Ultrason. Symp. (1997) 1319-1322
-
(1997)
IEEE Ultrason. Symp.
, pp. 1319-1322
-
-
Simon, C.1
VanBaren, P.2
Ebbini, E.3
-
27
-
-
56149102691
-
Method and experiment of noninvasive temperature estimation by ultrasound echo-pulses
-
Engineering in Medicine and Biology Society
-
H. Wang, H. Yu, F. Lin, Z. Xu, Method and experiment of noninvasive temperature estimation by ultrasound echo-pulses, in: Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society 20(3) (1998) 1513-1516.
-
(1998)
Proceedings of the 20th Annual International Conference of the IEEE
, vol.20
, Issue.3
, pp. 1513-1516
-
-
Wang, H.1
Yu, H.2
Lin, F.3
Xu, Z.4
-
28
-
-
0029464458
-
Non-invasive spatio-temporal temperature estimation using diagnostic ultrasound
-
Seip R., VanBaren P., Simon C., and Ebbini E.S. Non-invasive spatio-temporal temperature estimation using diagnostic ultrasound. IEEE Ultrason. Symp. (1995) 1613-1616
-
(1995)
IEEE Ultrason. Symp.
, pp. 1613-1616
-
-
Seip, R.1
VanBaren, P.2
Simon, C.3
Ebbini, E.S.4
-
29
-
-
0028730486
-
Invasive and non-invasive feedback for ultrasound phased array thermometry
-
Seip R., and Ebbini E.S. Invasive and non-invasive feedback for ultrasound phased array thermometry. Ultrason. Symp. (1994) 1821-1824
-
(1994)
Ultrason. Symp.
, pp. 1821-1824
-
-
Seip, R.1
Ebbini, E.S.2
-
31
-
-
0031383944
-
Ultrasonic mapping of temperature in hyperthermia: the thermal lens effect
-
Le Floch C., and Fink M. Ultrasonic mapping of temperature in hyperthermia: the thermal lens effect. IEEE Ultrason. Symp. (1997) 1301-1305
-
(1997)
IEEE Ultrason. Symp.
, pp. 1301-1305
-
-
Le Floch, C.1
Fink, M.2
-
33
-
-
0030291626
-
Noninvasive real-time multipoint temperature control for ultrasound phased array treatments
-
Seip R., VanBaren P., Cain C.A., and Ebbini E.S. Noninvasive real-time multipoint temperature control for ultrasound phased array treatments. IEEE Trans. Ultrason. Ferroelect. Freq. Control 43 6 (1996) 1063-1072
-
(1996)
IEEE Trans. Ultrason. Ferroelect. Freq. Control
, vol.43
, Issue.6
, pp. 1063-1072
-
-
Seip, R.1
VanBaren, P.2
Cain, C.A.3
Ebbini, E.S.4
-
34
-
-
13244298156
-
Noninvasive estimation of tissue temperature via high-resolution spectral analysis techniques
-
Nasiri A., Ebbini E.S., and Georgiou T.T. Noninvasive estimation of tissue temperature via high-resolution spectral analysis techniques. IEEE Trans. Biomed. Eng. 52 2 (2005) 221-228
-
(2005)
IEEE Trans. Biomed. Eng.
, vol.52
, Issue.2
, pp. 221-228
-
-
Nasiri, A.1
Ebbini, E.S.2
Georgiou, T.T.3
-
35
-
-
0033068159
-
A multi-gate time-of-flight technique for estimation of temperature distribution in heated tissue: theory and computer simulation
-
Sun Z., and Ying H. A multi-gate time-of-flight technique for estimation of temperature distribution in heated tissue: theory and computer simulation. Ultrasonics 37 (1999) 107-122
-
(1999)
Ultrasonics
, vol.37
, pp. 107-122
-
-
Sun, Z.1
Ying, H.2
-
36
-
-
0003561344
-
-
Lawrence S., and Marple Jr. (Eds), Prentice Hall
-
In: Lawrence S., and Marple Jr. (Eds). Digital Spectral Analysis with Applications (1987), Prentice Hall
-
(1987)
Digital Spectral Analysis with Applications
-
-
-
37
-
-
0025483468
-
Spectral characterization of tissues microstructure by ultrasounds: a stochastic Approach
-
Landini L., and Verrazzani L. Spectral characterization of tissues microstructure by ultrasounds: a stochastic Approach. IEEE Trans. Ultrason. Ferroelect. Freq. Control 37 5 (1990) 448-456
-
(1990)
IEEE Trans. Ultrason. Ferroelect. Freq. Control
, vol.37
, Issue.5
, pp. 448-456
-
-
Landini, L.1
Verrazzani, L.2
-
38
-
-
0026866522
-
Nonuniform phase distribution in ultrasound speckle analysis-Part II: parametric expression and a frequency sweeping technique to measure mean scatterer spacing
-
Weng L., Reid J.M., Shankar P.M., Soetanto K., and Lu X.-M. Nonuniform phase distribution in ultrasound speckle analysis-Part II: parametric expression and a frequency sweeping technique to measure mean scatterer spacing. IEEE Trans. Ultrason. Ferroelect. Freq. Control 39 3 (1992) 360-365
-
(1992)
IEEE Trans. Ultrason. Ferroelect. Freq. Control
, vol.39
, Issue.3
, pp. 360-365
-
-
Weng, L.1
Reid, J.M.2
Shankar, P.M.3
Soetanto, K.4
Lu, X.-M.5
-
39
-
-
0023332753
-
Statistical properties of radio-frequency and envelope-detected signals with applications to medical ultrasound
-
Wagner R.F., Insana M.F., and Brown D.G. Statistical properties of radio-frequency and envelope-detected signals with applications to medical ultrasound. J. Opt. Soc. Am. A 4 5 (1987) 910-922
-
(1987)
J. Opt. Soc. Am. A
, vol.4
, Issue.5
, pp. 910-922
-
-
Wagner, R.F.1
Insana, M.F.2
Brown, D.G.3
-
40
-
-
0028865648
-
A model for ultrasonic scattering from tissues based on the K distribution
-
Shankar P.M. A model for ultrasonic scattering from tissues based on the K distribution. Phys. Med. Biol. 40 (1995) 1633-1649
-
(1995)
Phys. Med. Biol.
, vol.40
, pp. 1633-1649
-
-
Shankar, P.M.1
-
41
-
-
0028843614
-
Modeling acoustic backscatter from kidney microstructure using an anisotropic correlation function
-
Insana F.M. Modeling acoustic backscatter from kidney microstructure using an anisotropic correlation function. J. Acoust. Soc. Am. 97 1 (1995) 649
-
(1995)
J. Acoust. Soc. Am.
, vol.97
, Issue.1
, pp. 649
-
-
Insana, F.M.1
-
42
-
-
0001946573
-
Application of autoregressive spectral analysis to cepstral estimation of mean scatterer spacing
-
Wear K.A., Wagner R.F., Insana F.M., and Hall T.J. Application of autoregressive spectral analysis to cepstral estimation of mean scatterer spacing. IEEE Trans. Ultrason. Ferroelect. Freq. Control 40 1 (1993) 50-58
-
(1993)
IEEE Trans. Ultrason. Ferroelect. Freq. Control
, vol.40
, Issue.1
, pp. 50-58
-
-
Wear, K.A.1
Wagner, R.F.2
Insana, F.M.3
Hall, T.J.4
-
43
-
-
0030734414
-
Studies on ultrasonic scattering from quasi-periodic structures
-
Narayanan V.M., Molthen R.C., Shankar P.M., Vergara L., and Reid J.M. Studies on ultrasonic scattering from quasi-periodic structures. IEEE Trans. Ultrason. Ferroelect. Freq. Control 44 1 (1997) 114-124
-
(1997)
IEEE Trans. Ultrason. Ferroelect. Freq. Control
, vol.44
, Issue.1
, pp. 114-124
-
-
Narayanan, V.M.1
Molthen, R.C.2
Shankar, P.M.3
Vergara, L.4
Reid, J.M.5
-
44
-
-
0017351885
-
Ultrasonic backscattering from human tissue, a realistic model
-
Gore J.C., and Leeman S. Ultrasonic backscattering from human tissue, a realistic model. Phys. Med. Biol. 22 2 (1977) 317-326
-
(1977)
Phys. Med. Biol.
, vol.22
, Issue.2
, pp. 317-326
-
-
Gore, J.C.1
Leeman, S.2
-
45
-
-
60549096146
-
-
I. Bazán, M. Vazquez, A. Ramos, A. Vera, L. Leija, A comparative analysis of three ultrasonic techniques for non-invasive temperature estimation in hyperthermia range, International Congress on Ultrasonics, Vienna, 2007. ICU Proceedings, pp. 1312.1-1312.4, doi:10.3728/ICUltrasonics.2007.Vienna.1312_bazan.
-
I. Bazán, M. Vazquez, A. Ramos, A. Vera, L. Leija, A comparative analysis of three ultrasonic techniques for non-invasive temperature estimation in hyperthermia range, International Congress on Ultrasonics, Vienna, 2007. ICU Proceedings, pp. 1312.1-1312.4, doi:10.3728/ICUltrasonics.2007.Vienna.1312_bazan.
-
-
-
-
46
-
-
60549113768
-
-
J.O. Montiel, M. Vázquez, A. Vera, L. Leija, Medición de atenuación y dispersión en phantoms para aplicaciones de hipertermia, SOMIB, Acapulco, Guerrero, 2005.
-
(2005)
Medición de atenuación y dispersión en phantoms para aplicaciones de hipertermia, SOMIB, Acapulco, Guerrero
-
-
Montiel, J.O.1
Vázquez, M.2
Vera, A.3
Leija, L.4
-
47
-
-
60549103115
-
-
J.O. Montiel, A. Vera, L. Leija, M. Vázquez, I. Bazán, Diseño de phantoms ultrasónicos para aplicaciones en hipertermia oncológica, SOMIB, Acapulco, Guerrero, 2005.
-
(2005)
Diseño de phantoms ultrasónicos para aplicaciones en hipertermia oncológica, SOMIB, Acapulco, Guerrero
-
-
Montiel, J.O.1
Vera, A.2
Leija, L.3
Vázquez, M.4
Bazán, I.5
-
48
-
-
0018872703
-
A new ultrasound tissue-equivalent material
-
Burlew M., Madsen E., and Zagzebski J. A new ultrasound tissue-equivalent material. Radiology 134 (1980) 517-520
-
(1980)
Radiology
, vol.134
, pp. 517-520
-
-
Burlew, M.1
Madsen, E.2
Zagzebski, J.3
-
49
-
-
0022721801
-
A easily made ultrasound biopsy phantom
-
Fredfeldt K. A easily made ultrasound biopsy phantom. Ultrasound Med. 5 (1986) 295-297
-
(1986)
Ultrasound Med.
, vol.5
, pp. 295-297
-
-
Fredfeldt, K.1
-
51
-
-
0031987372
-
Development of an example flow test object and comparison of five of these test objects, Constructed in various laboratories
-
Teirlinck C., Beemer R., and Kollmann C. Development of an example flow test object and comparison of five of these test objects, Constructed in various laboratories. Ultrasonics 38 (1998) 653-660
-
(1998)
Ultrasonics
, vol.38
, pp. 653-660
-
-
Teirlinck, C.1
Beemer, R.2
Kollmann, C.3
-
53
-
-
60549108437
-
Development of A Phantom to Mimick Soft Tissue with A Regular Scatterer Structure for Ultrasonic Use, OPS-OMS-IEEE
-
California
-
I. Bazán, A. Ramos, A. Vera, L. Leija, Development of A Phantom to Mimick Soft Tissue with A Regular Scatterer Structure for Ultrasonic Use, OPS-OMS-IEEE, Pan American Health Care Exchanges - PAHCE08 Conf. Proceedings, California, 2008, pp. 46-50.
-
(2008)
Pan American Health Care Exchanges - PAHCE08 Conf. Proceedings
, pp. 46-50
-
-
Bazán, I.1
Ramos, A.2
Vera, A.3
Leija, L.4
-
55
-
-
0033906416
-
Dependence of pulser driving responses on electrical and motional characteristics of NDE ultrasonic probes
-
Ramos A., SanEmeterio J.L., and Sanz P.T. Dependence of pulser driving responses on electrical and motional characteristics of NDE ultrasonic probes. Ultrasonics 38 1-8 (2000) 553-558
-
(2000)
Ultrasonics
, vol.38
, Issue.1-8
, pp. 553-558
-
-
Ramos, A.1
SanEmeterio, J.L.2
Sanz, P.T.3
-
56
-
-
33845865324
-
Pspice circuital modelling of ultrasonic imaging transceiver including frequency-dependent losses and signal distortions in electronic stages
-
Ramos A., SanEmeterio J.L., and Sanz P.T. Pspice circuital modelling of ultrasonic imaging transceiver including frequency-dependent losses and signal distortions in electronic stages. Ultrasonics 44e (2006) 995-1000
-
(2006)
Ultrasonics
, vol.44 e
, pp. 995-1000
-
-
Ramos, A.1
SanEmeterio, J.L.2
Sanz, P.T.3
|