Volumn , Issue , 2008, Pages 4205-4209

Iterative CT reconstruction using LabPETTM detector modules

Author keywords

[No Author keywords available]

Indexed keywords

BINNED DATA; COMPUTED TOMOGRAPHY; CT RECONSTRUCTION; CT SYSTEM; DETECTOR MODULE; DETECTOR RESPONSE; FRONT END ELECTRONIC; INPUT DATA; ITERATIVE RECONSTRUCTION; ITERATIVE RECONSTRUCTION ALGORITHMS; LOW-DOSE CT; MATRIX; PET IMAGES; PET IMAGING; PHOTON-COUNTING MODE; RASTER SCANS; SINOGRAM; SPATIAL RESOLUTION; SYSTEM GEOMETRY; SYSTEM MATRICES; X-RAY PHOTON COUNTING;

EID: 60549083802     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2008.4774209     Document Type: Conference Paper
Times cited : (6)

References (12)
  • 3
    • 11244304503 scopus 로고    scopus 로고
    • Micro-CT with respiratory and cardiac gating
    • DOI 10.1118/1.1812604
    • C. Badea, L.W. Hedlund, G.A. Johnson, "Micro-CT with respiratory and cardiac gating", Med. Phys., vol.31, no. 12, pp. 3324-3329,2004. (Pubitemid 40064984)
    • (2004) Medical Physics , vol.31 , Issue.12 , pp. 3324-3329
    • Badea, C.1    Hedlund, L.W.2    Johnson, G.A.3
  • 7
    • 33947720985 scopus 로고    scopus 로고
    • Statistical reconstruction for x-ray CT systems with non-continuous detectors
    • DOI 10.1088/0031-9155/52/2/007, PII S0031915507215581, 007
    • W. Zbijewski et al., "Statistical reconstruction for X-ray CT systems with non-continuous detectors", Phys. Med. Biol., vol.52, pp. 403-418, 2007. (Pubitemid 46646460)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.2 , pp. 403-418
    • Zbijewski, W.1    Defrise, M.2    Viergever, M.A.3    Beekman, F.J.4
  • 8
    • 0021952059 scopus 로고
    • Fast calculation of the exact radiological path for a three-dimensional CT array
    • DOI 10.1118/1.595715
    • R. L. Siddon, "Fast calculation of the exact radiological path for a threedimensional CT array", Med. Phys., vol.12, pp. 252-255,1985. (Pubitemid 15089015)
    • (1985) Medical Physics , vol.12 , Issue.2 , pp. 252-255
    • Siddon, R.L.1
  • 10
    • 0032216626 scopus 로고    scopus 로고
    • Accelerated iterative transmission CT reconstruction using an ordered subsets convex algorithm
    • PII S0278006298096785
    • C. Kamphuis, F.J. Beekman, "Accelerated iterative transmission CT reconstruction using an ordered subsets convex algorithm", IEEE Trans. Med. Imaging, vol.17, pp.ll0l-ll05, 1998. (Pubitemid 128747770)
    • (1998) IEEE Transactions on Medical Imaging , vol.17 , Issue.6 , pp. 1101-1105
    • Kamphuis, C.1    Beekman, F.J.2
  • 11
    • 0031807850 scopus 로고    scopus 로고
    • Selection of task-dependent diffusion filters for the post-processing of SPECT images
    • DOI 10.1088/0031-9155/43/6/024, PII S0031915598830443
    • F.J. Beekman, E.T.P. Slijpen, W.J. Niessen, "Selection of taskdependent diffusion filters for the post-processing of SPECT images", Phys. Med. Biol., vol.43, pp. 1713-1730,1998. (Pubitemid 28277304)
    • (1998) Physics in Medicine and Biology , vol.43 , Issue.6 , pp. 1713-1730
    • Beekman, F.J.1    Slijpen, E.T.P.2    Niessen, W.J.3
  • 12
    • 0345832268 scopus 로고    scopus 로고
    • Characterization and suppression of edge and aliasing artefacts in iterative x-ray CT reconstruction
    • DOI 10.1088/0031-9155/49/1/010, PII S0031915504663718
    • W. Zbijewski, F.J. Beekman, "Characterization and suppression of edge and aliasing artefacts in iterative x-ray CT reconstruction", Phys. Med. Biol., no. 49, pp. 145-157,2004. (Pubitemid 38100628)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.1 , pp. 145-157
    • Zbijewski, W.1    Beekman, F.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.