Volumn 60, Issue 2, 2009, Pages 79-86

Potential mapping technique for the detection of corrosion in reinforced concrete structures: Investigation of parameters influencing the measurement and determination of the reliability of the method

Author keywords

[No Author keywords available]

Indexed keywords

ANODES; BUILDING MATERIALS; CHLORINE COMPOUNDS; ELECTRODES; ENAMELS; REINFORCED CONCRETE; RELIABILITY; STEEL; WATER CONTENT;

EID: 60349108913     PISSN: 09475117     EISSN: 15214176     Source Type: Journal    
DOI: 10.1002/maco.200805042     Document Type: Article
Times cited : (16)

References (16)
  • 1
    • 0012282645 scopus 로고
    • Standard Test Method for Half-cell Potential of Reinforcing Steel in Concrete
    • ASTM C876-91, American Society for Testing and Materials
    • ASTM C876-91, Standard Test Method for Half-cell Potential of Reinforcing Steel in Concrete, American Society for Testing and Materials, 1991.
    • (1991)
  • 6
    • 60349119434 scopus 로고    scopus 로고
    • C. C. Naish, A. Harker, R. F. Carney, Concrete inspection: Interpretation of potential and resistivity measurements, in: C. Page, K. W. J. Treadaway, P. B. Bamforth, (Eds.), Corrosion of Reinforcement in Concrete, Elsevier Applied Science, London, 1990, pp. 314-332.
    • C. C. Naish, A. Harker, R. F. Carney, Concrete inspection: Interpretation of potential and resistivity measurements, in: C. Page, K. W. J. Treadaway, P. B. Bamforth, (Eds.), Corrosion of Reinforcement in Concrete, Elsevier Applied Science, London, 1990, pp. 314-332.
  • 7
    • 60349132078 scopus 로고    scopus 로고
    • 3M, Zinc-Hydrogel Anode 4727, Product Guide 2006.
    • 3M, Zinc-Hydrogel Anode 4727, Product Guide 2006.
  • 10
    • 60349129608 scopus 로고    scopus 로고
    • Dissertation ETH Zürich, Nr. 15567
    • M. Brem, Dissertation ETH Zürich, Nr. 15567, 2004.
    • (2004)
    • Brem, M.1
  • 12
  • 15
    • 60349084082 scopus 로고    scopus 로고
    • NACE, Houston, TX, USA, Report 97278
    • R. Myrdal, CORROSION/97, NACE, Houston, TX, USA, 1997, Report 97278.
    • (1997) CORROSION/97
    • Myrdal, R.1
  • 16
    • 60349118980 scopus 로고    scopus 로고
    • NACE, Houston, TX, USA, Report 96339
    • R. Myrdal, CORROSION/96, NACE, Houston, TX, USA, 1996, Report 96339.
    • (1996) CORROSION/96
    • Myrdal, R.1