-
2
-
-
0035822607
-
Development and testing of the helex septal occluder, a new expanded polytetrafluoroethylene atrial septal defect occlusion system
-
Zahn EM, Wilson N, Cutright W, Latson LA. Development and testing of the helex septal occluder, a new expanded polytetrafluoroethylene atrial septal defect occlusion system. Circulation 2001;104:711-716.
-
(2001)
Circulation
, vol.104
, pp. 711-716
-
-
Zahn, E.M.1
Wilson, N.2
Cutright, W.3
Latson, L.A.4
-
3
-
-
4243226464
-
Transcatheter closure of secundum atrial septal defects using the new nitinol self-expandable, repositionable amplatzer septal occluder: Initial clinical experience
-
Masura J, Walsh KP, Gavora P, Holan M, Hijazi ZM. Transcatheter closure of secundum atrial septal defects using the new nitinol self-expandable, repositionable amplatzer septal occluder: Initial clinical experience. Circulation 1997;96: 3177.
-
(1997)
Circulation
, vol.96
, pp. 3177
-
-
Masura, J.1
Walsh, K.P.2
Gavora, P.3
Holan, M.4
Hijazi, Z.M.5
-
4
-
-
0029152912
-
Memory metal stents for palliation of malignant obstruction of the esophagus and cardia
-
May A, Selmaier M, Hochberger J, Gossner L, Muhldorfer S, Hahn EG, Ell C. Memory metal stents for palliation of malignant obstruction of the esophagus and cardia. Gut 1995;37: 309-313.
-
(1995)
Gut
, vol.37
, pp. 309-313
-
-
May, A.1
Selmaier, M.2
Hochberger, J.3
Gossner, L.4
Muhldorfer, S.5
Hahn, E.G.6
Ell, C.7
-
6
-
-
15744367081
-
Pseudoelasticity of near-equiatomic Ni-Ti shape memory alloy
-
Pelton AR, Hodgson D, Duerig T, editors, California: Pacific Grove;
-
Zhang CS, Wang YQ, Cheng JX, Zhao CL. Pseudoelasticity of near-equiatomic Ni-Ti shape memory alloy. In: Pelton AR, Hodgson D, Duerig T, editors. Shape Memory and Superelastic Technologies. California: Pacific Grove; 1994. p 383-388.
-
(1994)
Shape Memory and Superelastic Technologies
, pp. 383-388
-
-
Zhang, C.S.1
Wang, Y.Q.2
Cheng, J.X.3
Zhao, C.L.4
-
7
-
-
0036735279
-
First closure of a large patent ductus arteriosus in an infant with an angulated nitinol plug
-
Ewert P, Kretschmar O, Nuernberg JH, Nagdyman N, Lange PE. First closure of a large patent ductus arteriosus in an infant with an angulated nitinol plug. Catheter Cardiovasc Interv 2002;57:88-91.
-
(2002)
Catheter Cardiovasc Interv
, vol.57
, pp. 88-91
-
-
Ewert, P.1
Kretschmar, O.2
Nuernberg, J.H.3
Nagdyman, N.4
Lange, P.E.5
-
8
-
-
0030340747
-
On the nature of the biocompatibility and on medical applications of Ni-Ti shape memory and superelastic alloys
-
Shabalovskaya SA. On the nature of the biocompatibility and on medical applications of Ni-Ti shape memory and superelastic alloys. Biomed Mater Eng 1996;6:267-289.
-
(1996)
Biomed Mater Eng
, vol.6
, pp. 267-289
-
-
Shabalovskaya, S.A.1
-
9
-
-
0031214566
-
Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy
-
Wever DJ, Veldhuizen AG, Sanders MM, Schakenraad JM, vanHorn JR. Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy. Biomaterials 1997;18:1115-1120.
-
(1997)
Biomaterials
, vol.18
, pp. 1115-1120
-
-
Wever, D.J.1
Veldhuizen, A.G.2
Sanders, M.M.3
Schakenraad, J.M.4
vanHorn, J.R.5
-
10
-
-
0345129973
-
Preliminary investigation of the effects of surface treatments on biological response to shape memory NiTi stents
-
Trepanier C, Leung TK, Tabrizian M, Yahia L, Bienvenu JG, Tanguay JF, et al. Preliminary investigation of the effects of surface treatments on biological response to shape memory NiTi stents. J Biomed Mater Res 1999;48:165-171.
-
(1999)
J Biomed Mater Res
, vol.48
, pp. 165-171
-
-
Trepanier, C.1
Leung, T.K.2
Tabrizian, M.3
Yahia, L.4
Bienvenu, J.G.5
Tanguay, J.F.6
-
11
-
-
0036179018
-
Surface, corrosion and biocompatibility aspects of nitinol as an implant material
-
Shabalovskaya SA. Surface, corrosion and biocompatibility aspects of nitinol as an implant material. Biomed Mater Eng 2002;12:69-109.
-
(2002)
Biomed Mater Eng
, vol.12
, pp. 69-109
-
-
Shabalovskaya, S.A.1
-
12
-
-
0141670820
-
Biocompatibility and hemocompatibility of surface-modified NiTi alloys
-
Armitage DA, Parker TL, Grant DM. Biocompatibility and hemocompatibility of surface-modified NiTi alloys. J Biomed Mater Res A 2003;66:129-137.
-
(2003)
J Biomed Mater Res A
, vol.66
, pp. 129-137
-
-
Armitage, D.A.1
Parker, T.L.2
Grant, D.M.3
-
13
-
-
84956040351
-
Surface spectroscopic characterization of tini nearly equiatomic shape-memory alloys for implants
-
Shabalovskaya SA, Anderegg JW. Surface spectroscopic characterization of tini nearly equiatomic shape-memory alloys for implants. J Vacuum Sci Technol: A Vacuum Surface Film 1995;13:2624-2632.
-
(1995)
J Vacuum Sci Technol: A Vacuum Surface Film
, vol.13
, pp. 2624-2632
-
-
Shabalovskaya, S.A.1
Anderegg, J.W.2
-
14
-
-
0033119606
-
Localized corrosion behaviour in simulated human body fluids of commercial Ni-Ti orthodontic wires
-
Rondelli G, Vicentini B. Localized corrosion behaviour in simulated human body fluids of commercial Ni-Ti orthodontic wires. Biomaterials 1999;20:785-792.
-
(1999)
Biomaterials
, vol.20
, pp. 785-792
-
-
Rondelli, G.1
Vicentini, B.2
-
15
-
-
0037089606
-
Passivation of nitinol wire for vascular implants - A demonstration of the benefits
-
O'Brien B, Carroll WM, Kelly MJ. Passivation of nitinol wire for vascular implants - A demonstration of the benefits. Biomaterials 2002;23:1739-1748.
-
(2002)
Biomaterials
, vol.23
, pp. 1739-1748
-
-
O'Brien, B.1
Carroll, W.M.2
Kelly, M.J.3
-
16
-
-
0041467739
-
Effect of chemical etching and aging in boiling water on the corrosion resistance of nitinol wires with black oxide resulting from manufacturing process
-
Shabalovskaya S, Rondelli G, Anderegg J, Simpson B, Budko S. Effect of chemical etching and aging in boiling water on the corrosion resistance of nitinol wires with black oxide resulting from manufacturing process. J Biomed Mater Res B: Appl Biomater 2003;66:331-340.
-
(2003)
J Biomed Mater Res B: Appl Biomater
, vol.66
, pp. 331-340
-
-
Shabalovskaya, S.1
Rondelli, G.2
Anderegg, J.3
Simpson, B.4
Budko, S.5
-
18
-
-
33646356220
-
New oxidation treatment of NiTi shape memory alloys to obtain Ni-free surfaces and to improve biocompatibility
-
Michiardi A, Aparicio C, Planell JA, Gil FJ. New oxidation treatment of NiTi shape memory alloys to obtain Ni-free surfaces and to improve biocompatibility. J Biomed Mater Res B: Appl Biomater 2006;77:249-256.
-
(2006)
J Biomed Mater Res B: Appl Biomater
, vol.77
, pp. 249-256
-
-
Michiardi, A.1
Aparicio, C.2
Planell, J.A.3
Gil, F.J.4
-
19
-
-
0034333624
-
Increased corrosion resistance of stent materials by converting current surface film of polycrystalline oxide into amorphous oxide
-
Shih CC, Lin SJ, Chung KH, Chen YL, Su YY. Increased corrosion resistance of stent materials by converting current surface film of polycrystalline oxide into amorphous oxide. J Biomed Mater Res 2000;52:323-332.
-
(2000)
J Biomed Mater Res
, vol.52
, pp. 323-332
-
-
Shih, C.C.1
Lin, S.J.2
Chung, K.H.3
Chen, Y.L.4
Su, Y.Y.5
-
20
-
-
0037026414
-
Effect of surface treatment of NiTi alloy on its corrosion behavior in Hanks' solution
-
Cisse O, Savadogo O, Wu M, Yahia L. Effect of surface treatment of NiTi alloy on its corrosion behavior in Hanks' solution. J Biomed Mater Res 2002;61:339-345.
-
(2002)
J Biomed Mater Res
, vol.61
, pp. 339-345
-
-
Cisse, O.1
Savadogo, O.2
Wu, M.3
Yahia, L.4
-
21
-
-
0034911604
-
Corroded nitinol wires in explanted aortic endografts: An important mechanism of failure?
-
Heintz C, Riepe G, Birken L, Kaiser E, Chakfe N, Morlock M, et al. Corroded nitinol wires in explanted aortic endografts: An important mechanism of failure? J Endovasc Ther 2001;8:248-253.
-
(2001)
J Endovasc Ther
, vol.8
, pp. 248-253
-
-
Heintz, C.1
Riepe, G.2
Birken, L.3
Kaiser, E.4
Chakfe, N.5
Morlock, M.6
-
23
-
-
0025192709
-
The corrosion behavior of nickel titanium shape memory alloys
-
Rondelli G, Vicentini B, Gigada A. The corrosion behavior of nickel titanium shape memory alloys. Corros Sci 1990;30:805-812.
-
(1990)
Corros Sci
, vol.30
, pp. 805-812
-
-
Rondelli, G.1
Vicentini, B.2
Gigada, A.3
-
24
-
-
0034038826
-
Evaluation by electrochemical tests of the passive film stability of equiatomic Ni-Ti alloy also in presence of stress-induced martensite
-
Rondelli G, Vicentini B. Evaluation by electrochemical tests of the passive film stability of equiatomic Ni-Ti alloy also in presence of stress-induced martensite. J Biomed Mater Res 2000;51:47-54.
-
(2000)
J Biomed Mater Res
, vol.51
, pp. 47-54
-
-
Rondelli, G.1
Vicentini, B.2
-
25
-
-
0036888313
-
Surface oxidation of NiTi shape memory alloy
-
Firstov GS, Vitchev RG, Kumar H, Blanpain B, Van Humbeeck J. Surface oxidation of NiTi shape memory alloy. Biomaterials 2002;23:4863-4871.
-
(2002)
Biomaterials
, vol.23
, pp. 4863-4871
-
-
Firstov, G.S.1
Vitchev, R.G.2
Kumar, H.3
Blanpain, B.4
Van Humbeeck, J.5
-
26
-
-
7844250509
-
Improvement in corrosion resistance in Ni-Ti shape memory alloy for implant by oxide film coating
-
Presented at the, Kyoto, Japan, April 21-25
-
Sohmura T. Improvement in corrosion resistance in Ni-Ti shape memory alloy for implant by oxide film coating. Presented at the Third World Biomaterials Congress, Kyoto, Japan, April 21-25, 1988; p 574.
-
(1988)
Third World Biomaterials Congress
, pp. 574
-
-
Sohmura, T.1
-
27
-
-
2642558867
-
Oxidation of nitinol and its effect on corrosion resistance
-
Presented at the, Anaheim, California
-
Zhu L, Trépanier C, Pelton A, Fino JM.Oxidation of nitinol and its effect on corrosion resistance. Presented at the ASM Materials and Processes for Medical Devices Conference, Anaheim, California, 2003.
-
(2003)
ASM Materials and Processes for Medical Devices Conference
-
-
Zhu, L.1
Trépanier, C.2
Pelton, A.3
Fino, J.M.4
-
28
-
-
34547888787
-
The release of nickel from orthodontic NiTi wire is increased by dynamic mechanical loading but not constrained by surface nitridation
-
Peitsch T, Klocke A, Kahl-Nieke B, Prymak O, Epple M. The release of nickel from orthodontic NiTi wire is increased by dynamic mechanical loading but not constrained by surface nitridation. J Biomed Mater Res A 2007;82:731-739.
-
(2007)
J Biomed Mater Res A
, vol.82
, pp. 731-739
-
-
Peitsch, T.1
Klocke, A.2
Kahl-Nieke, B.3
Prymak, O.4
Epple, M.5
-
29
-
-
0002679588
-
Simulated annealing analysis of Rutherford backscattering data
-
Barradas NP, Jeynes C, Webb RP. Simulated annealing analysis of Rutherford backscattering data. Appl Phys Lett 1997; 71:291-293.
-
(1997)
Appl Phys Lett
, vol.71
, pp. 291-293
-
-
Barradas, N.P.1
Jeynes, C.2
Webb, R.P.3
-
30
-
-
0026819282
-
Anodizing titanium for space applications
-
Sharma AK. Anodizing titanium for space applications. Thin Solid Films 1992;208:48-54.
-
(1992)
Thin Solid Films
, vol.208
, pp. 48-54
-
-
Sharma, A.K.1
-
31
-
-
0031361048
-
Initiation and propagation of localized deformation in elasto-plastic strips under uniaxial tension
-
Shaw JA, Kyriakides S. Initiation and propagation of localized deformation in elasto-plastic strips under uniaxial tension. Int J Plasticity 1997;13:837-871.
-
(1997)
Int J Plasticity
, vol.13
, pp. 837-871
-
-
Shaw, J.A.1
Kyriakides, S.2
-
32
-
-
0031078592
-
On the nucleation and propagation of phase transformation fronts in a NiTi alloy
-
Shaw JA, Kyriakides S. On the nucleation and propagation of phase transformation fronts in a NiTi alloy. Acta Materialia 1997;45:683-700.
-
(1997)
Acta Materialia
, vol.45
, pp. 683-700
-
-
Shaw, J.A.1
Kyriakides, S.2
-
33
-
-
20444487357
-
On the origin of Luders-like deformation of NiTi shape memory alloys
-
Sittner P, Liu Y, Novak V. On the origin of Luders-like deformation of NiTi shape memory alloys. J Mech Phys Solids 2005;53:1719-1746.
-
(2005)
J Mech Phys Solids
, vol.53
, pp. 1719-1746
-
-
Sittner, P.1
Liu, Y.2
Novak, V.3
-
35
-
-
60349130630
-
-
online database
-
Goodfellow. online database: http://www.goodfellow.com/csp/active/static/ A/Titanium-Dioxide.HTML. Goodfellow Cambridge Limited 2007.
-
(2007)
Goodfellow Cambridge Limited
-
-
-
36
-
-
0036968070
-
Easy assessment of the biocompatibility of Ni-Ti alloys by in vitro cell culture experiments on a functionally graded Ni-NiTi-Ti material
-
Bogdanski D, Koller M, Muller D, Muhr G, Bram M, Buchkremer HP, et al. Easy assessment of the biocompatibility of Ni-Ti alloys by in vitro cell culture experiments on a functionally graded Ni-NiTi-Ti material. Biomaterials 2002;23:4549-4555.
-
(2002)
Biomaterials
, vol.23
, pp. 4549-4555
-
-
Bogdanski, D.1
Koller, M.2
Muller, D.3
Muhr, G.4
Bram, M.5
Buchkremer, H.P.6
-
37
-
-
6444223943
-
Characterisation of surface oxidation of nickel-titanium alloy by ion-beam and electrochemical techniques
-
Barison S, Cattarin S, Daolio S, Musiani M, Tuissi A. Characterisation of surface oxidation of nickel-titanium alloy by ion-beam and electrochemical techniques. Electrochim Acta 2004;50:11-18.
-
(2004)
Electrochim Acta
, vol.50
, pp. 11-18
-
-
Barison, S.1
Cattarin, S.2
Daolio, S.3
Musiani, M.4
Tuissi, A.5
|