메뉴 건너뛰기




Volumn 29, Issue 1, 2009, Pages 13-22

Computational and experimental optimization of a double-tuned 1H/ 31P four-ring birdcage head coil for MRS at 3T

Author keywords

Double tuned RF coils; FDTD; MRI; MRS; Numerical modeling; Optimization

Indexed keywords

ARTICLE; CONTROLLED STUDY; MAGNETIC FIELD; MATHEMATICAL MODEL; NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY; PHOSPHORUS NUCLEAR MAGNETIC RESONANCE; PRIORITY JOURNAL; PROTON NUCLEAR MAGNETIC RESONANCE; THREE DIMENSIONAL IMAGING;

EID: 60349101737     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21509     Document Type: Article
Times cited : (22)

References (23)
  • 1
    • 0016310555 scopus 로고
    • Observation of tissue metabolites using 31P nuclear magnetic resonance
    • Hoult DI, Busby SJW, Gadian DG, et al. Observation of tissue metabolites using 31P nuclear magnetic resonance. Nature 1974;252:282-287.
    • (1974) Nature , vol.252 , pp. 282-287
    • Hoult, D.I.1    Busby, S.J.W.2    Gadian, D.G.3
  • 2
    • 0020970042 scopus 로고
    • Medical applications of nuclear magnetic resonance
    • Young IR. Medical applications of nuclear magnetic resonance. Acta Radiol Suppl 1983;365:70-72.
    • (1983) Acta Radiol Suppl , vol.365 , pp. 70-72
    • Young, I.R.1
  • 4
    • 0022728431 scopus 로고
    • Control of bioenergetics: Frp, cells to man by phosphorous NMR. 19th Ciba Medal Lecture
    • Radda GK. Control of bioenergetics: frp, cells to man by phosphorous NMR. 19th Ciba Medal Lecture, Biochem Soc Trans 1986;14:517-525.
    • (1986) Biochem Soc Trans , vol.14 , pp. 517-525
    • Radda, G.K.1
  • 5
    • 0000698011 scopus 로고
    • Depth resolved surface coil spectroscopy (DRESS) for in-vivo H-1, P-31, and C-13 NMR
    • Bottomley PA, Foster TB, Darrow RD. Depth resolved surface coil spectroscopy (DRESS) for in-vivo H-1, P-31, and C-13 NMR. J Magn Reson 1984;59:338-346.
    • (1984) J Magn Reson , vol.59 , pp. 338-346
    • Bottomley, P.A.1    Foster, T.B.2    Darrow, R.D.3
  • 6
    • 0000597869 scopus 로고
    • Quadrature detection coils-a further Sqrt(2) improvement in sensitivity
    • Chen C-N, Hoult DI, Sank VJ. Quadrature detection coils-a further Sqrt(2) improvement in sensitivity. J Magn Reson 1983;54:324-327.
    • (1983) J Magn Reson , vol.54 , pp. 324-327
    • Chen, C.-N.1    Hoult, D.I.2    Sank, V.J.3
  • 8
    • 46549092488 scopus 로고
    • An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 T
    • Hayes CE, Edelstein WA, Schenck JF, et al. An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 T. J Magn Reson 1985;63:622-628.
    • (1985) J Magn Reson , vol.63 , pp. 622-628
    • Hayes, C.E.1    Edelstein, W.A.2    Schenck, J.F.3
  • 9
    • 38249017194 scopus 로고
    • A design for a double-tuned birdcage coil for use in an integrated MRI/MRS examination
    • Isaac G, Schnall M, Lenkinski R, et al. A design for a double-tuned birdcage coil for use in an integrated MRI/MRS examination. J Magn Reson 1990;89:41-50.
    • (1990) J Magn Reson , vol.89 , pp. 41-50
    • Isaac, G.1    Schnall, M.2    Lenkinski, R.3
  • 10
    • 0009569536 scopus 로고
    • Design and performance of double-tuned birdcage coil
    • Rath AR. Design and performance of double-tuned birdcage coil. J Magn Reson 1990;86:488-495.
    • (1990) J Magn Reson , vol.86 , pp. 488-495
    • Rath, A.R.1
  • 11
    • 0028380011 scopus 로고
    • Two configuration of the four-ring birdcage coil for 1H imaging and 1H decoupled 31P spectroscopy of the human head
    • Murphy-Bocsch J, Srinivasan R, Carvaial L, et al. Two configuration of the four-ring birdcage coil for 1H imaging and 1H decoupled 31P spectroscopy of the human head. J Magn Reson 1994;B103:103-114.
    • (1994) J Magn Reson , vol.B103 , pp. 103-114
    • Murphy-Bocsch, J.1    Srinivasan, R.2    Carvaial, L.3
  • 14
    • 25444451952 scopus 로고    scopus 로고
    • Double-frequency birdcage volume coils for 4.7T and 7T
    • Tomanek B, Volotovsky V, Gruwel M, et al. Double-frequency birdcage volume coils for 4.7T and 7T. Concepts Magn Reson 2006;26B:16-22.
    • (2006) Concepts Magn Reson , vol.26 B , pp. 16-22
    • Tomanek, B.1    Volotovsky, V.2    Gruwel, M.3
  • 15
    • 84894021661 scopus 로고
    • Numerical solution of initial boundary value problem involving Maxwell's equations in isotropic media
    • Yee KS. Numerical solution of initial boundary value problem involving Maxwell's equations in isotropic media. IEEE Trans Antennas Propagation 1966;AP-14:302-307.
    • (1966) IEEE Trans Antennas Propagation , vol.AP-14 , pp. 302-307
    • Yee, K.S.1
  • 16
    • 0032080159 scopus 로고    scopus 로고
    • Numerical simulation of SAR and B1-field inhomogeneity of shielded RF coils loaded with the human head
    • Chen J, Feng Z, Jin JM. Numerical simulation of SAR and B1-field inhomogeneity of shielded RF coils loaded with the human head. IEEE Trans Biomed Eng 1998;45:650-659.
    • (1998) IEEE Trans Biomed Eng , vol.45 , pp. 650-659
    • Chen, J.1    Feng, Z.2    Jin, J.M.3
  • 17
    • 0034746155 scopus 로고    scopus 로고
    • 1 field homogeneity and SAR calculations for the birdcage coil
    • 1 field homogeneity and SAR calculations for the birdcage coil. Phys Med Biol 2001;46:609-619.
    • (2001) Phys Med Biol , vol.46 , pp. 609-619
    • Ibrahim, T.S.1    Lee, R.2    Baertlein, B.A.3
  • 18
    • 0033770165 scopus 로고    scopus 로고
    • Computational analysis of the high pass birdcage resonator: Finite difference time domain simulations for high-field MRI
    • Ibrahim TS, Lee R, Baertlein BA, et al. Computational analysis of the high pass birdcage resonator: finite difference time domain simulations for high-field MRI. Magn Reson Imaging 2000;18:835-843.
    • (2000) Magn Reson Imaging , vol.18 , pp. 835-843
    • Ibrahim, T.S.1    Lee, R.2    Baertlein, B.A.3
  • 19
    • 0033877307 scopus 로고    scopus 로고
    • Application of finite difference time domain method for the design of birdcage RF head coil using multi-port excitation
    • Ibrahim TS, Lee R, Baertlein BA, et al. Application of finite difference time domain method for the design of birdcage RF head coil using multi-port excitation. Magn Reson Imaging 2000;18:733-742.
    • (2000) Magn Reson Imaging , vol.18 , pp. 733-742
    • Ibrahim, T.S.1    Lee, R.2    Baertlein, B.A.3
  • 20
    • 28044459877 scopus 로고
    • A perfectly matched layer for the absorption of electromagnetic waves
    • Berenger JP. A perfectly matched layer for the absorption of electromagnetic waves. J Comput Phys 1994;114:185-200.
    • (1994) J Comput Phys , vol.114 , pp. 185-200
    • Berenger, J.P.1
  • 21
    • 0030239565 scopus 로고    scopus 로고
    • Three dimensional perfectly matched layer for the absorption of electromagnetic waves
    • Berenger JP. Three dimensional perfectly matched layer for the absorption of electromagnetic waves. J Comput Phys 1996;127:363-379.
    • (1996) J Comput Phys , vol.127 , pp. 363-379
    • Berenger, J.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.