3
-
-
70349931736
-
Fire dynamics simulator (version 4) - user's guide
-
National Institute of Standards and Technology, US Department of Commerce
-
McGrattan K.B., and Forney G.P. Fire dynamics simulator (version 4) - user's guide. NIST Special Publication vol. 1019 (September 2005), National Institute of Standards and Technology, US Department of Commerce
-
(2005)
NIST Special Publication
, vol.1019
-
-
McGrattan, K.B.1
Forney, G.P.2
-
4
-
-
33646702357
-
Fire dynamics simulator (version 4) - technical reference guide
-
National Institute of Standards and Technology, US Department of Commerce
-
McGrattan K.B. Fire dynamics simulator (version 4) - technical reference guide. NIST Special Publication vol. 1018 (September 2005), National Institute of Standards and Technology, US Department of Commerce
-
(2005)
NIST Special Publication
, vol.1018
-
-
McGrattan, K.B.1
-
6
-
-
34548293073
-
(WCFD1)Verification and validation' in modeling fire by computational fluid dynamics
-
Mok W.K., and Chow W.K. (WCFD1)Verification and validation' in modeling fire by computational fluid dynamics. International Journal on Architectural Science 5 3 (2004) 58-67
-
(2004)
International Journal on Architectural Science
, vol.5
, Issue.3
, pp. 58-67
-
-
Mok, W.K.1
Chow, W.K.2
-
7
-
-
60249101067
-
-
Ingasson H, Olsson S. Interaction between sprinklers and fire vents. SP Report 1992.11, Swedish National Testing and Research Institute, Sweden; 1992.
-
Ingasson H, Olsson S. Interaction between sprinklers and fire vents. SP Report 1992.11, Swedish National Testing and Research Institute, Sweden; 1992.
-
-
-
-
9
-
-
19744371839
-
Evaluation of the field model, fire dynamics simulator, for a specific experimental scenario
-
Zou G.W., and Chow W.K. Evaluation of the field model, fire dynamics simulator, for a specific experimental scenario. Journal of Fire Protection Engineering 15 (2005) 77-92
-
(2005)
Journal of Fire Protection Engineering
, vol.15
, pp. 77-92
-
-
Zou, G.W.1
Chow, W.K.2
-
12
-
-
32644439424
-
Quantitative comparison of FDS and parametric fire curves with post-flashover compartment fire test data
-
Pope N.D., and Bailey C.G. Quantitative comparison of FDS and parametric fire curves with post-flashover compartment fire test data. Fire Safety Journal 41 (2006) 99-110
-
(2006)
Fire Safety Journal
, vol.41
, pp. 99-110
-
-
Pope, N.D.1
Bailey, C.G.2
-
13
-
-
60249103488
-
-
Verification and validation of selected fire models for nuclear power plant applications (NUREG-1824, vols. 1-7) - draft report for comment, US Nuclear Regulatory Commission plans. Available from: http://www.nrc.gov/reading-rm/doc-collections/nuregs/staff/sr1824. [This NUREG publication has been issued for public comment. The comment period closed on March 31, 2006].
-
Verification and validation of selected fire models for nuclear power plant applications (NUREG-1824, vols. 1-7) - draft report for comment, US Nuclear Regulatory Commission plans. Available from: http://www.nrc.gov/reading-rm/doc-collections/nuregs/staff/sr1824. [This NUREG publication has been issued for public comment. The comment period closed on March 31, 2006].
-
-
-
-
14
-
-
0007719634
-
-
Australian Standard™, Standards Australia (Standards Association of Australia), NSW
-
AS 4391-1999. Smoke management systems - hot smoke test (1999), Australian Standard™, Standards Australia (Standards Association of Australia), NSW
-
(1999)
Smoke management systems - hot smoke test
-
-
AS 4391-19991
-
15
-
-
34548225467
-
Atrium hot smoke tests in a big shopping complex
-
Chow W.K., Edgar Pang C.L., Han S.S., Dong H., Zou G.W., Gao Y., et al. Atrium hot smoke tests in a big shopping complex. Journal of Applied Fire Science 14 (2005-2006) 137-169
-
(2005)
Journal of Applied Fire Science
, vol.14
, pp. 137-169
-
-
Chow, W.K.1
Edgar Pang, C.L.2
Han, S.S.3
Dong, H.4
Zou, G.W.5
Gao, Y.6
-
18
-
-
10444236854
-
-
NIST GCR 01-810, National Institute of Standards and Technology, Gaithersburg, MD, USA
-
Friday P.A., and Mowrer F.W. Comparison of FDS model predictions with FM/SNL fire test data (2001), NIST GCR 01-810, National Institute of Standards and Technology, Gaithersburg, MD, USA
-
(2001)
Comparison of FDS model predictions with FM/SNL fire test data
-
-
Friday, P.A.1
Mowrer, F.W.2
-
19
-
-
60249103259
-
Communication called industry's weakness
-
Rose E. Communication called industry's weakness. ASHRAE Journal 45 11 (2003) 55-56
-
(2003)
ASHRAE Journal
, vol.45
, Issue.11
, pp. 55-56
-
-
Rose, E.1
|