메뉴 건너뛰기




Volumn 39, Issue 12, 2008, Pages 727-729

A high-throughput nonimmunological method for determination of microalbuminuria based on utilization of albumin blue 580

Author keywords

[No Author keywords available]

Indexed keywords


EID: 59849115812     PISSN: 00075027     EISSN: None     Source Type: Journal    
DOI: 10.1309/LMVDTG6F2UG5QHYH     Document Type: Article
Times cited : (5)

References (18)
  • 1
    • 34247557107 scopus 로고    scopus 로고
    • Microalbumin, renal disease, metabolic syndrome and risk in diabetes
    • Mogensen CE. Microalbumin, renal disease, metabolic syndrome and risk in diabetes. Diab Met Syndr Clin Res Rev. 2007;1:127-133.
    • (2007) Diab Met Syndr Clin Res Rev , vol.1 , pp. 127-133
    • Mogensen, C.E.1
  • 2
    • 0000656517 scopus 로고    scopus 로고
    • Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus
    • Sacks DB, Bruns DE, Goldstein DE, et al. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Diabetes Care. 2002;25:750-786.
    • (2002) Diabetes Care , vol.25 , pp. 750-786
    • Sacks, D.B.1    Bruns, D.E.2    Goldstein, D.E.3
  • 3
    • 1642396544 scopus 로고    scopus 로고
    • Microalbuminuria: Prevalence in hypertensives and diabetics
    • Col M, Ocaktan E, Ozdemir O, et al. Microalbuminuria: Prevalence in hypertensives and diabetics. Acta Med Austriaca. 2004;31:23-29.
    • (2004) Acta Med Austriaca , vol.31 , pp. 23-29
    • Col, M.1    Ocaktan, E.2    Ozdemir, O.3
  • 4
    • 34748862301 scopus 로고    scopus 로고
    • Microalbuminuria and cardiovascular disease
    • Weir MR. Microalbuminuria and cardiovascular disease. Clin J Am Soc Nephrol: CJASN. 2007;2:581-590.
    • (2007) Clin J Am Soc Nephrol: CJASN , vol.2 , pp. 581-590
    • Weir, M.R.1
  • 5
    • 0018166150 scopus 로고
    • Radioimmunoassay for urinary albumin
    • Woo J, Floyd M, Cannon DC, et al. Radioimmunoassay for urinary albumin. Clin Chem. 1978;24:1464-1467.
    • (1978) Clin Chem , vol.24 , pp. 1464-1467
    • Woo, J.1    Floyd, M.2    Cannon, D.C.3
  • 6
    • 0023234611 scopus 로고
    • Immunoturbidimetry: An attractive technique for the determination of urinary albumin and transferrin
    • Rifai N, Gubar K, Silverman LM. Immunoturbidimetry: An attractive technique for the determination of urinary albumin and transferrin. Clin Biochem. 1987;20:179-181.
    • (1987) Clin Biochem , vol.20 , pp. 179-181
    • Rifai, N.1    Gubar, K.2    Silverman, L.M.3
  • 7
    • 0023780638 scopus 로고
    • Measurement of albumin in urine by end-point immunonephelometry
    • Stamp RJ. Measurement of albumin in urine by end-point immunonephelometry. Ann Clin Biochem. 1988;25:442-443.
    • (1988) Ann Clin Biochem , vol.25 , pp. 442-443
    • Stamp, R.J.1
  • 8
    • 18744373899 scopus 로고    scopus 로고
    • Microplate ELISA for urine microalbumin: Reference values and results in patients with type 2 diabetes and cardiovascular disease
    • Wu TL, Chang PY, Li CC, et al. Microplate ELISA for urine microalbumin: Reference values and results in patients with type 2 diabetes and cardiovascular disease. Ann Clin Lab Sci. 2005;35:149-154.
    • (2005) Ann Clin Lab Sci , vol.35 , pp. 149-154
    • Wu, T.L.1    Chang, P.Y.2    Li, C.C.3
  • 9
    • 2642583969 scopus 로고    scopus 로고
    • On-site quantification of human urinary albumin by a fluorescence immunoassay
    • Choi S, Choi EY, Kim HS, et al. On-site quantification of human urinary albumin by a fluorescence immunoassay. Clin Chem. 2004;50:1052-1055.
    • (2004) Clin Chem , vol.50 , pp. 1052-1055
    • Choi, S.1    Choi, E.Y.2    Kim, H.S.3
  • 10
    • 34347342699 scopus 로고    scopus 로고
    • A rapid and sensitive immunoresonance scattering spectral assay for microalbumin
    • Liang AH, Huang YJ, Jiang ZL. A rapid and sensitive immunoresonance scattering spectral assay for microalbumin. Clin Chim Acta. 2007;383:73-77.
    • (2007) Clin Chim Acta , vol.383 , pp. 73-77
    • Liang, A.H.1    Huang, Y.J.2    Jiang, Z.L.3
  • 11
    • 0034034743 scopus 로고    scopus 로고
    • Evaluation of a new fluorescent dye method to measure urinary albumin in lieu of urinary total protein
    • Pegoraro AA, Peracha W, Hasnain M, et al. Evaluation of a new fluorescent dye method to measure urinary albumin in lieu of urinary total protein. Am J Kidney Dis. 2000;35:739-744.
    • (2000) Am J Kidney Dis , vol.35 , pp. 739-744
    • Pegoraro, A.A.1    Peracha, W.2    Hasnain, M.3
  • 12
    • 33645799065 scopus 로고    scopus 로고
    • Analytical validation of an HPLC assay for urinary albumin
    • Contois JH, Rao LV, Snyder LM, et al. Analytical validation of an HPLC assay for urinary albumin. Clin Chim Acta. 2006;367:150-155.
    • (2006) Clin Chim Acta , vol.367 , pp. 150-155
    • Contois, J.H.1    Rao, L.V.2    Snyder, L.M.3
  • 13
    • 41649084176 scopus 로고    scopus 로고
    • Measurement of microalbuminuria using protein chip electrophoresis
    • Pandey S, Lu CM, Herold DA. Measurement of microalbuminuria using protein chip electrophoresis. Am J Clin Pathol. 2008;129:432-438.
    • (2008) Am J Clin Pathol , vol.129 , pp. 432-438
    • Pandey, S.1    Lu, C.M.2    Herold, D.A.3
  • 14
    • 35748967293 scopus 로고    scopus 로고
    • Successive determination of urinary protein and glucose using spectrophotometric sequential injection method
    • Kanchana Wi, Sakai T, Teshima N, et al. Successive determination of urinary protein and glucose using spectrophotometric sequential injection method. Anal Chim Acta. 2007;604:139-146.
    • (2007) Anal Chim Acta , vol.604 , pp. 139-146
    • Kanchana, W.1    Sakai, T.2    Teshima, N.3
  • 15
    • 0031570351 scopus 로고    scopus 로고
    • Albumin blue 580 fluorescence assay for albumin
    • Kessler MA, Meinitzer A, Wolfbeis OS. Albumin blue 580 fluorescence assay for albumin. Anal Biochem. 1997;248:180-182.
    • (1997) Anal Biochem , vol.248 , pp. 180-182
    • Kessler, M.A.1    Meinitzer, A.2    Wolfbeis, O.S.3
  • 16
    • 0030975133 scopus 로고    scopus 로고
    • Microalbuminuria and borderline-increased albumin excretion determined with a centrifugal analyzer and the Albumin Blue 580 fluorescence assay
    • Kessler MA, Meinitzer A, Peter W, et al. Microalbuminuria and borderline-increased albumin excretion determined with a centrifugal analyzer and the Albumin Blue 580 fluorescence assay. Clin Chem. 1997;43:996-1002.
    • (1997) Clin Chem , vol.43 , pp. 996-1002
    • Kessler, M.A.1    Meinitzer, A.2    Peter, W.3
  • 17
    • 23644434281 scopus 로고    scopus 로고
    • Towards microalbuminuria determination on a disposable diagnostic microchip with integrated fluorescence detection based on thin-film organic light emitting diodes
    • Hofmann O, Wang X, DeMello JC, et al. Towards microalbuminuria determination on a disposable diagnostic microchip with integrated fluorescence detection based on thin-film organic light emitting diodes. Lab Chip - Miniaturisation Chem Biol. 2005;5:863-868.
    • (2005) Lab Chip - Miniaturisation Chem Biol , vol.5 , pp. 863-868
    • Hofmann, O.1    Wang, X.2    DeMello, J.C.3
  • 18
    • 0035181692 scopus 로고    scopus 로고
    • Analysis of albumins, using albumin blue 580, by capillary electrophoresis and laser-induced fluorescence
    • Tseng WL, Chiu TC, Weng JM, et al. Analysis of albumins, using albumin blue 580, by capillary electrophoresis and laser-induced fluorescence. J Liq Chromatogr R T. 2001;24:2971-2982.
    • (2001) J Liq Chromatogr R T , vol.24 , pp. 2971-2982
    • Tseng, W.L.1    Chiu, T.C.2    Weng, J.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.