메뉴 건너뛰기




Volumn 43, Issue 4, 2009, Pages 315-330

Tensile properties of CFRP and hybrid FRP composites at elevated temperatures

Author keywords

FRP; High temperature properties; Hybrid; Mechanical testing.

Indexed keywords

CARBON FIBER REINFORCED PLASTICS; FIBER REINFORCED PLASTICS; FIBERS; GLASS TRANSITION; HIGH TEMPERATURE PROPERTIES; MECHANICAL TESTING; POLYMERS; REINFORCED PLASTICS; REINFORCEMENT; TEMPERATURE;

EID: 59849109666     PISSN: 00219983     EISSN: 1530793X     Source Type: Journal    
DOI: 10.1177/0021998308099224     Document Type: Article
Times cited : (254)

References (22)
  • 4
    • 0023308728 scopus 로고
    • Composites for High Temperatures, Pure and Appl
    • Fitzer, E. (1988). Composites for High Temperatures, Pure and Appl. Chem., 60 (3). 287-302.
    • (1988) Chem. , vol.60 , Issue.3 , pp. 287-302
    • Fitzer, E.1
  • 5
    • 1642323527 scopus 로고    scopus 로고
    • The Tensile Behavior of Carbon Fibers at High Temperatures up to 2400°C
    • Sauder, C., Acques Lamon, J. and Pailler, R. (2004). The Tensile Behavior of Carbon Fibers at High Temperatures up to 2400°C, Carbon, 42: 715-725.
    • (2004) Carbon , vol.42 , pp. 715-725
    • Sauder, C.1    Acques Lamon, J.2    Pailler, R.3
  • 6
    • 59849118393 scopus 로고    scopus 로고
    • The Applications of the CBF in War Industry and Civil Fields
    • Hu, X. and Shen, T. (2005). The Applications of the CBF in War Industry and Civil Fields, Hi-Tech Fiber and Application, 30 (6). 7-13.
    • (2005) Hi-Tech Fiber and Application , vol.30 , Issue.6 , pp. 7-13
    • Hu, X.1    Shen, T.2
  • 8
    • 38549096492 scopus 로고    scopus 로고
    • Fire Endurance of Fiber-Reinforced Polymer Strengthened Concrete T-beams
    • Williams, B., Kodur, V., Green, M.F. and Bisby, L. (2008). Fire Endurance of Fiber-Reinforced Polymer Strengthened Concrete T-beams, ACI Structural Journal, Jan.-Feb.: 60-67.
    • (2008) ACI Structural Journal , pp. 60-67
    • Williams, B.1    Kodur, V.2    Green, M.F.3    Bisby, L.4
  • 9
  • 10
    • 34548476535 scopus 로고    scopus 로고
    • Investigation of Insulated FRP-wrapped Reinforced Concrete Columns in Fire
    • Chowdhury, E.U., Bisby, L.A., Green, M.F. and Kodur, V.K.R. (2007). Investigation of Insulated FRP-wrapped Reinforced Concrete Columns in Fire, Fire Safety Journal, 42: 452-460.
    • (2007) Fire Safety Journal , vol.42 , pp. 452-460
    • Chowdhury, E.U.1    Bisby, L.A.2    Green, M.F.3    Kodur, V.K.R.4
  • 12
    • 33746338913 scopus 로고    scopus 로고
    • Structural Response of Liquid-cooled GFRP Slabs Subjected to fire-Part II: Thermo-chemical and Thermo-mechanical Modeling
    • Keller, T., Tracy, C. and Zhou, A. (2006). Structural Response of Liquid-cooled GFRP Slabs Subjected to fire-Part II: Thermo-chemical and Thermo-mechanical Modeling, Composites Part A, 37: 1296-1308.
    • (2006) Composites Part A , vol.37 , pp. 1296-1308
    • Keller, T.1    Tracy, C.2    Zhou, A.3
  • 13
    • 34848839830 scopus 로고    scopus 로고
    • Modeling of Post-Fire Stiffness of E-Glass Fiber-Reinforced Polyester Composites
    • Bai, Y. and Keller, T. (2007). Modeling of Post-Fire Stiffness of E-Glass Fiber-Reinforced Polyester Composites, Composites Part A, 38: 2142-2153.
    • (2007) Composites Part A , vol.38 , pp. 2142-2153
    • Bai, Y.1    Keller, T.2
  • 15
    • 0018923645 scopus 로고
    • Temperature Effects on Epoxy Adhesives, Journal of the Structural Division
    • Plecnik, J. (1980). Temperature Effects on Epoxy Adhesives, Journal of the Structural Division, ASCE, 106 (1). 99-113.
    • (1980) ASCE , vol.106 , Issue.1 , pp. 99-113
    • Plecnik, J.1
  • 16
    • 0036790047 scopus 로고    scopus 로고
    • Effect of Fire on FRP Reinforced Concrete Members
    • Saafi, M. (2002). Effect of Fire on FRP Reinforced Concrete Members, Composite Structures 58: 11-20.
    • (2002) Composite Structures , vol.58 , pp. 11-20
    • Saafi, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.