Volumn 23, Issue 6, 2008, Pages 2710-2718

A T-connected transformer and three-leg VSC based DSTATCOM for power quality improvement

Author keywords

Distribution static compensator (DSTATCOM); Neutral current compensation; Power quality improvement; T connected transformer; Voltage source converter (VSC)

Indexed keywords

AC GENERATOR MOTORS; ACTIVE FILTERS; BIPOLAR TRANSISTORS; ELECTRIC CONVERTERS; ELECTRIC LOAD DISTRIBUTION; ELECTRIC MEASURING INSTRUMENTS; ELECTRIC POWER FACTOR; INSULATED GATE BIPOLAR TRANSISTORS (IGBT); MATLAB; POWER CONVERTERS; POWER QUALITY; TRANSISTORS; VOLTAGE REGULATORS; WIRE;

EID: 59849104709     PISSN: 08858993     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPEL.2008.2004273     Document Type: Article
Times cited : (150)

References (20)
  • 7
    • 59849096918 scopus 로고    scopus 로고
    • Method and apparatus for reducing the harmonic currents in alternating current distribution networks,
    • U.S. Patent 5 576 942, Nov. 19
    • L. H. Beverly, R. D. Hance, A. L. Kristalinski, and A. T. Visser, "Method and apparatus for reducing the harmonic currents in alternating current distribution networks," U.S. Patent 5 576 942, Nov. 19, 1996.
    • (1996)
    • Beverly, L.H.1    Hance, R.D.2    Kristalinski, A.L.3    Visser, A.T.4
  • 8
    • 17844397739 scopus 로고    scopus 로고
    • Analysis of zig-zag transformer applying in the three-phase four-wire distribution power system
    • Apr
    • H.-L. Jou, J.-C. Wu, K.-D. Wu, W.-J. Chiang, and Y.-H. Chen, "Analysis of zig-zag transformer applying in the three-phase four-wire distribution power system," IEEE Trans. Power Del., vol. 20, no. 2, pp. 1168-1173, Apr. 2005.
    • (2005) IEEE Trans. Power Del , vol.20 , Issue.2 , pp. 1168-1173
    • Jou, H.-L.1    Wu, J.-C.2    Wu, K.-D.3    Chiang, W.-J.4    Chen, Y.-H.5
  • 9
    • 38349055044 scopus 로고    scopus 로고
    • A three-phase four-wire power filter comprising a three-phase three-wire active filter and a zig-zag transformer
    • Jan
    • H.-L. Jou, K.-D. Wu, J.-C. Wu, and W.-J. Chiang, "A three-phase four-wire power filter comprising a three-phase three-wire active filter and a zig-zag transformer," IEEE Trans. Power Electron., vol. 23, no. 1, pp. 252-259, Jan. 2008.
    • (2008) IEEE Trans. Power Electron , vol.23 , Issue.1 , pp. 252-259
    • Jou, H.-L.1    Wu, K.-D.2    Wu, J.-C.3    Chiang, W.-J.4
  • 10
    • 59849127356 scopus 로고    scopus 로고
    • Novel power converter topology for three-phase four-wire hybrid power filter
    • H. L. Jou, K. D. Wu, J. C. Wu, C. H. Li, and M. S. Huang, "Novel power converter topology for three-phase four-wire hybrid power filter," IET Power Electron., vol. 1, no. 1, pp. 164-173, 2008.
    • (2008) IET Power Electron , vol.1 , Issue.1 , pp. 164-173
    • Jou, H.L.1    Wu, K.D.2    Wu, J.C.3    Li, C.H.4    Huang, M.S.5
  • 11
    • 34248642030 scopus 로고    scopus 로고
    • Voltage-regulation performance of a shunt active filter intended for installation on a power distribution system
    • May
    • H. Fugita and H. Akagi, "Voltage-regulation performance of a shunt active filter intended for installation on a power distribution system," IEEE Trans. Power Electron., vol. 22, no. 1, pp. 1046-1053, May 2007.
    • (2007) IEEE Trans. Power Electron , vol.22 , Issue.1 , pp. 1046-1053
    • Fugita, H.1    Akagi, H.2
  • 12
    • 12344250880 scopus 로고    scopus 로고
    • New control approach for four-wire active power filter based on the use of synchronous reference frame
    • Mar
    • M. C. Benhabib and S. Saadate, "New control approach for four-wire active power filter based on the use of synchronous reference frame," Electr. Power Syst. Res., vol. 73, no. 3, pp. 353-362, Mar. 2005.
    • (2005) Electr. Power Syst. Res , vol.73 , Issue.3 , pp. 353-362
    • Benhabib, M.C.1    Saadate, S.2
  • 13
    • 33846932082 scopus 로고    scopus 로고
    • Comparison of control strategies for shunt active power filters in three-phase four-wire systems
    • Jan
    • M. I. Milanés, E. R. Cadaval, and F. B. González, "Comparison of control strategies for shunt active power filters in three-phase four-wire systems," IEEE Trans. Power Electron., vol. 22, no. 1, pp. 229-236, Jan. 2007.
    • (2007) IEEE Trans. Power Electron , vol.22 , Issue.1 , pp. 229-236
    • Milanés, M.I.1    Cadaval, E.R.2    González, F.B.3
  • 14
    • 59849104364 scopus 로고
    • Analysis of T-T connections of two single phase transformers
    • Feb
    • B. A. Cogbill and J. A. Hetrick, "Analysis of T-T connections of two single phase transformers," IEEE Trans. Power App. Syst., vol. PAS-87, no. 2, pp. 388-394, Feb. 1968.
    • (1968) IEEE Trans. Power App. Syst , vol.PAS-87 , Issue.2 , pp. 388-394
    • Cogbill, B.A.1    Hetrick, J.A.2
  • 16
    • 38349015079 scopus 로고    scopus 로고
    • A novel T-connected autotransformer-based 18-pulse AC-DC converter for harmonic mitigation in adjustable-speed induction-motor drives
    • Oct
    • B. Singh, V. Garg, and G. Bhuvaneswari, "A novel T-connected autotransformer-based 18-pulse AC-DC converter for harmonic mitigation in adjustable-speed induction-motor drives," IEEE Trans. Ind. Electron., vol. 54, no. 5, pp. 2500-2511, Oct. 2007.
    • (2007) IEEE Trans. Ind. Electron , vol.54 , Issue.5 , pp. 2500-2511
    • Singh, B.1    Garg, V.2    Bhuvaneswari, G.3
  • 17
    • 3042563500 scopus 로고    scopus 로고
    • Design, simulation and implementation of three pole/four pole topologies for active filters
    • Jul
    • B. N. Singh, P. Rastgoufard, B. Singh, A. Chandra, and K. A. Haddad, "Design, simulation and implementation of three pole/four pole topologies for active filters," in Inst. Electr. Eng. Proc. Electr. Power Appl., Jul. 2004, vol. 151, no. 4, pp. 467-476.
    • (2004) Inst. Electr. Eng. Proc. Electr. Power Appl , vol.151 , Issue.4 , pp. 467-476
    • Singh, B.N.1    Rastgoufard, P.2    Singh, B.3    Chandra, A.4    Haddad, K.A.5
  • 18
    • 0029481792 scopus 로고
    • Synchronous frame based controller implementation for a hybrid series active filter system
    • S. Bhattacharya and D. Diwan, "Synchronous frame based controller implementation for a hybrid series active filter system," in Proc. IEEE Ind. Appl. Soc. Meeting 1995, pp. 2531-2540.
    • (1995) Proc. IEEE Ind. Appl. Soc. Meeting , pp. 2531-2540
    • Bhattacharya, S.1    Diwan, D.2
  • 20
    • 0028542835 scopus 로고
    • Analysis and design of a new active power filter to cancel neutral current harmonics in three-phase four-wire electric distribution systems
    • Nov./Dec
    • P. Enjeti, W. Shireen, P. Packebush, and I. Pitel, "Analysis and design of a new active power filter to cancel neutral current harmonics in three-phase four-wire electric distribution systems," IEEE Trans. Ind. Appl., vol. 30, no. 6, pp. 1565-1572, Nov./Dec. 1994.
    • (1994) IEEE Trans. Ind. Appl , vol.30 , Issue.6 , pp. 1565-1572
    • Enjeti, P.1    Shireen, W.2    Packebush, P.3    Pitel, I.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.