메뉴 건너뛰기




Volumn 7, Issue 6, 2008, Pages 535-546

Noise-based wavelet denoising technique for partial discharge measurement

Author keywords

Discrete wavelet transform; Frequency tuned resonance; Oscilating voltage wave; Partial discharge; Power cables; Very low frequency

Indexed keywords

CABLE INSULATION; DE-NOISING; DE-NOISING TECHNIQUES; HIGH VOLTAGE CABLE; HIGH VOLTAGE POWER CABLES; INSULATION QUALITY; MEDIUM VOLTAGE; MOTHER WAVELETS; OSCILATING VOLTAGE WAVE; PARTIAL DISCHARGE MEASUREMENTS; PD MEASUREMENTS; PD PULSE; POWER CABLES; SELECTION ALGORITHM; SIMULATION STUDIES; TEST METHOD; TESTING METHOD; VERY LOW FREQUENCY; VOLTAGE WAVES; WAVELET DE-NOISING TECHNIQUES; XLPE CABLES;

EID: 59649129705     PISSN: 11092734     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (24)
  • 1
    • 0344009301 scopus 로고    scopus 로고
    • Partial discharge fault analysis of SIR-based cable terminations
    • J. J. Smit, E. Gulski and E. Pultrum, Partial Discharge Fault Analysis of SIR-based Cable Terminations, 10th ISH, 1997, pp.513-516.
    • (1997) 10th ISH , pp. 513-516
    • Smit, J.J.1    Gulski, E.2    Pultrum, E.3
  • 3
    • 0025482241 scopus 로고
    • The wavelet transform, timefrequency localization and signal analysis
    • I. Daubechies, The Wavelet Transform, TimeFrequency Localization and Signal Analysis, IEEE Trans. Information Theory, Vol.36, 1990, pp. 961-1005.
    • (1990) IEEE Trans. Information Theory , vol.36 , pp. 961-1005
    • Daubechies, I.1
  • 4
    • 0034538745 scopus 로고    scopus 로고
    • Investigation into the use of wavelet theory for partial discharge pulse extraction in electrically, noisy environments
    • Edinburgh.UK
    • X. Mal C. Zhou and I. J. Kemp, Investigation into the Use of Wavelet Theory for Partial Discharge Pulse Extraction in Electrically, Noisy Environments . Proc. 8th International Conference on Materials, Measurements and Applications, Edinburgh.UK, 2000, pp. 123-126.
    • (2000) Proc. 8th International Conference on Materials, Measurements and Applications , pp. 123-126
    • Mal, X.1    Zhou, C.2    Kemp, I.J.3
  • 5
    • 29944431575 scopus 로고    scopus 로고
    • Suppression of partial discharge's discrete spectral interference based on spectrum estimation and wavelet packet transform
    • Xiao Yan, Yu Weiyong, Huang Chengjun and Jiang Chuanwen, Suppression of Partial Discharge's Discrete Spectral Interference Based on Spectrum Estimation and Wavelet Packet Transform, WSEAS Transactions on Circuits and Systems, Vol.4, No.11, 2005, pp. 1508-1515.
    • (2005) WSEAS Transactions on Circuits and Systems , vol.4 , Issue.11 , pp. 1508-1515
    • Yan, X.1    Weiyong, Y.2    Chengjun, H.3    Chuanwen, J.4
  • 6
    • 77951734291 scopus 로고    scopus 로고
    • Naderi, a new technique for extracting partial discharge signals in transformer winding by application of wavelet analysis
    • Mohammad S. Naderi, M. Vakilian, T.R Blackburn, B.T. Phung and Mehdi S. Naderi, A New Technique for Extracting Partial Discharge Signals in Transformer Winding by Application of Wavelet Analysis, WSEAS Transactions on Power Systems, Vol.1, No.1, 2006, pp. 77-83.
    • (2006) WSEAS Transactions on Power Systems , vol.1 , Issue.1 , pp. 77-83
    • Mohammad, S.1    Vakilian, N.M.2    Blackburn, T.R.3    Phung, B.T.4    Mehdi, S.5
  • 7
    • 29844437035 scopus 로고    scopus 로고
    • Investigation of multi-wavelet denoising in partial discharge detection
    • Qian Yong, Huang Cheng-jun and Jiang Xiuchen, Investigation of Multi-wavelet Denoising in Partial Discharge Detection, WSEAS Transactions on Circuits and Systems, Vol.5, No.1, 2006, pp. 85-91. (Pubitemid 43033980)
    • (2006) WSEAS Transactions on Circuits and Systems , vol.5 , Issue.1 , pp. 85-91
    • Qian, Y.1    Huang, C.-J.2    Jiang, X.-C.3
  • 8
    • 0344034147 scopus 로고    scopus 로고
    • Selectivity of damped ac(DAC) and VLF voltages in after-laying tests of extruded MV cable systems
    • Bolarin Oyegoke, Petri Hyvonen, Martti Aro and Ning Gao, Selectivity of Damped ac(DAC) and VLF Voltages in After-laying Tests of Extruded MV Cable Systems, IEEE transactions on dielectrics and electrical insulation, Vol.10, No.5, 2003, pp. 874-882.
    • (2003) IEEE Transactions on Dielectrics and Electrical Insulation , vol.10 , Issue.5 , pp. 874-882
    • Oyegoke, B.1    Hyvonen, P.2    Aro, M.3    Gao, N.4
  • 10
    • 0036613463 scopus 로고    scopus 로고
    • Interpretation of wavelet analysis and its application in partial discharge detection
    • X. Ma, C. Zhou and I.J. Kemp, Interpretation of wavelet analysis and its application in partial discharge detection, IEEE Trans. Diel. Elect.Insul, Vol.9, 2002, pp.446-457.
    • (2002) IEEE Trans. Diel. Elect.Insul , vol.9 , pp. 446-457
    • Ma, X.1    Zhou, C.2    Kemp, I.J.3
  • 11
    • 0037732564 scopus 로고    scopus 로고
    • Wavelet-based denoising of partial discharge signals buried in excessive noise and interference
    • L. Satish and B. Nazneen, Wavelet-based Denoising of Partial Discharge Signals Buried in Excessive Noise and Interference, IEEE Trans. Dielectr. Electr. Insul, Vol.10, 2003, pp. 354-367.
    • (2003) IEEE Trans. Dielectr. Electr. Insul. , vol.10 , pp. 354-367
    • Satish, L.1    Nazneen, B.2
  • 12
    • 33847740252 scopus 로고    scopus 로고
    • A novel wavelet transform technique for on-line partial discharge measurements part 1: WT de-noising algorithm
    • DOI 10.1109/TDEI.2007.302864
    • H. Zhang, T.R. Blackburn, B.T. Phung and D.Sen, A novel wavelet transform technique for on-line partial discharge measurements part 1 : WT de-noising algorithm, IEEE transactions on dielectrics and electrical insulation, Vol.14, No.1,2007, pp. 3-14. (Pubitemid 46375876)
    • (2007) IEEE Transactions on Dielectrics and Electrical Insulation , vol.14 , Issue.1 , pp. 3-14
    • Zhang, H.1    Blackburn, T.R.2    Phung, B.T.3    Sen, D.4
  • 16
    • 0035078588 scopus 로고    scopus 로고
    • Detection of PD utilizing digital signal processing methods, part 3: Open-loop noise eduction
    • I. Shim, I. J. Soraghan and W. H. Siew, Detection of PD Utilizing Digital Signal Processing Methods, Part 3: Open-Loop Noise eduction, IEEE Electrical Insulation Magazine, Vol.17, No.1, 1997, pp. 6-11.
    • (1997) IEEE Electrical Insulation Magazine , vol.17 , Issue.1 , pp. 6-11
    • Shim, I.1    Soraghan, I.J.2    Siew, W.H.3
  • 17
    • 0342420604 scopus 로고    scopus 로고
    • A noise reduction technique for on-line detection and location of partial discharges in high voltage cable networks
    • I. Shim, I. I. Soraghan and W. H. Siew, A Noise Reduction Technique for On-line Detection and Location of Partial Discharges in High Voltage Cable Networks, Measurement Science Technology, Vol.11, 2000, pp. 1708-1713.
    • (2000) Measurement Science Technology , vol.11 , pp. 1708-1713
    • Shim, I.1    Soraghan, I.I.2    Siew, W.H.3
  • 19
    • 20444471563 scopus 로고    scopus 로고
    • Application of signal processing techniques to on-line partial discharge detection in cables
    • Paper No. MB7.2D.L
    • H. Zhang, T.R. Blackburn, B.T. Phung and Z.Liu, Application of signal processing techniques to on-line partial discharge detection in cables, Intern. Conf. Power System Technology, Paper No. MB7.2D.L, 2004.
    • (2004) Intern. Conf. Power System Technology
    • Zhang, H.1    Blackburn, T.R.2    Phung, B.T.3    Liu, Z.4
  • 20
    • 33847696897 scopus 로고    scopus 로고
    • A novel wavelet transform technique for on-line partial discharge measurements part 2: On-site noise rejection application
    • DOI 10.1109/TDEI.2007.302865
    • H. Zhang, T.R. Blackburn, B.T. Phung and D.Sen, A novel wavelet transform technique for on-line partial discharge measurements part 2: on-site noise rejection application, IEEE transactions on dielectrics and electrical insulation, Vol.14, No.1, 2007, pp. 15-22. (Pubitemid 46375877)
    • (2007) IEEE Transactions on Dielectrics and Electrical Insulation , vol.14 , Issue.1 , pp. 15-22
    • Zhang, H.1    Blackburn, T.R.2    Phung, B.T.3    Sen, D.4
  • 21
    • 0035078588 scopus 로고    scopus 로고
    • Detection of PD utilizing digital signal processing methods part 3: Open-loop noise reduction
    • I. Shim, J. J. Soraghan and W. H. Siew, Detection of PD Utilizing Digital Signal Processing Methods Part 3: Open-Loop Noise Reduction, IEEE Electr. Insul. Mag., Vol.17. No.1, 2001, pp.6-13.
    • (2001) IEEE Electr. Insul. Mag. , vol.17 , Issue.1 , pp. 6-13
    • Shim, I.1    Soraghan, J.J.2    Siew, W.H.3
  • 22
    • 22744458250 scopus 로고    scopus 로고
    • An improved methodology for application of wavelet transform to partial discharge measurement denoising
    • DOI 10.1109/TDEI.2005.1453464
    • X.Zhou, C.Zhou and I.J.Kemp, An Improved Methodology for Application of Wavelet Transform to Partial Discharge Measurement Denoising, IEEE transactions on dielectrics and electrical insulation, Vol.12, No.3, 2005, pp.586-594. (Pubitemid 41028280)
    • (2005) IEEE Transactions on Dielectrics and Electrical Insulation , vol.12 , Issue.3 , pp. 586-594
    • Zhou, X.1    Zhou, C.2    Kemp, I.J.3
  • 23
    • 0036505569 scopus 로고    scopus 로고
    • Automated wavelet selection and thresholding for PD detection
    • X. Ma, C. Zhou, and I. J. Kemp, Automated wavelet selection and thresholding for PD detection, IEEE Elect. Insul. Mag., vol.18, no.2, 2002, pp. 37-45.
    • (2002) IEEE Elect. Insul. Mag. , vol.18 , Issue.2 , pp. 37-45
    • Ma, X.1    Zhou, C.2    Kemp, I.J.3
  • 24
    • 55149124192 scopus 로고    scopus 로고
    • Study of partial discharge measurement in power equipment using acoustic technique and wavelet transform
    • Li-Jung Chen, Whei-Min Lin, Member, IEEE, Ta-Peng Tsao, and Yu-Hsun Lin, Study of Partial Discharge Measurement in Power Equipment Using Acoustic Technique and Wavelet Transform, IEEE Transaction on Power Delivery, vol.22, no.3, 2007, pp. 1575-1580.
    • (2007) IEEE Transaction on Power Delivery , vol.22 , Issue.3 , pp. 1575-1580
    • Chen, L.-J.1    Lin, W.-M.2    Member, I.3    Tsao, T.-P.4    Lin, Y.-H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.