메뉴 건너뛰기




Volumn 47, Issue SUPPL. 2, 2008, Pages 18-21

CFD simulation and optimization design of double skin facade

Author keywords

CFD; Double skin facade; Heat removing rate

Indexed keywords

ENERGY CONSERVATION; ENERGY MANAGEMENT; HEAT TRANSFER; SKIN; THERMOANALYSIS;

EID: 59649120466     PISSN: 05296579     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (7)

References (9)
  • 1
    • 59649089928 scopus 로고    scopus 로고
    • A mathematical model of thermal channel glazing curtain wall
    • CHENG Yihua, SA Shizhong, ZHOU Yasu, et al. A mathematical model of thermal channel glazing curtain wall [J]. Building Energy & Environment, 2005, 24 (6): 9-18.
    • (2005) Building Energy & Environment , vol.24 , Issue.6 , pp. 9-18
    • Cheng, Y.1    Sa, S.2    Zhou, Y.3
  • 3
    • 0035480458 scopus 로고    scopus 로고
    • Thermal transmittance of multiple glazing: Computational fluid dynamics prediction
    • GAN G.. Thermal transmittance of multiple glazing: Computational fluid dynamics prediction [J]. Applied Thermal Engineering, 2001, 21: 1583-1592.
    • (2001) Applied Thermal Engineering , vol.21 , pp. 1583-1592
    • Gan, G.1
  • 5
    • 0348230730 scopus 로고    scopus 로고
    • Total solar energy transmittance of glass double facades with free convection
    • MANZ H. Total solar energy transmittance of glass double facades with free convection [J]. Journal of Energy and Building, 2004, 36: 127-136.
    • (2004) Journal of Energy and Building , vol.36 , pp. 127-136
    • Manz, H.1
  • 6
    • 43049098552 scopus 로고    scopus 로고
    • Natural ventilation in the double skin faade with venetian blind
    • XU Xiaoli, ZHAO Yang. Natural ventilation in the double skin faade with venetian blind [J]. Journal of Energy and Buildings, 2008, 40: 1498-1504.
    • (2008) Journal of Energy and Buildings , vol.40 , pp. 1498-1504
    • Xu, X.1    Zhao, Y.2
  • 7
    • 37449010409 scopus 로고    scopus 로고
    • Numerical investigation on thermal performance and correlations of double skin facade with buoyancy-driven airflow
    • ALEXANDRA P, ZHAI Zhiqiang. Numerical investigation on thermal performance and correlations of double skin facade with buoyancy-driven airflow [J]. Journal of Energy and Buildings, 2008, 40: 466-475.
    • (2008) Journal of Energy and Buildings , vol.40 , pp. 466-475
    • Alexandra, P.1    Zhai, Z.2
  • 8
    • 0030359150 scopus 로고    scopus 로고
    • Heat transfer coefficient of architectural window with energy efficient coating
    • GU Peifu, LI Xiu, HUANG Shengjun, et al. Heat transfer coefficient of architectural window with energy efficient coating [J]. Acta Optica Sinica, 1996, 16 (12): 1832-1835.
    • (1996) Acta Optica Sinica , vol.16 , Issue.12 , pp. 1832-1835
    • Gu, P.1    Li, X.2    Huang, S.3
  • 9
    • 59649126852 scopus 로고    scopus 로고
    • Heat transfer analysis for double skin facade of building based on CFD fluid model
    • ZHANG Guixian, CHEN Lidong, DING Ou. Heat transfer analysis for double skin facade of building based on CFD fluid model [J]. Construction & Design for Project, 2003 (9): 4-7.
    • (2003) Construction & Design for Project , Issue.9 , pp. 4-7
    • Zhang, G.1    Chen, L.2    Ding, O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.