메뉴 건너뛰기




Volumn 11, Issue 2, 2009, Pages 178-183

Gradual power titration using radiofrequency energy: A safe method for slow-pathway ablation in the setting of atrioventricular nodal re-entrant tachycardia

Author keywords

Atrioventricular nodal re entrant tachycardia; Complete heart block; Gradual power titration; Radiofrequency energy; Slow pathway ablation

Indexed keywords

ACCELERATION; ADOLESCENT; ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; ATRIOVENTRICULAR BLOCK; ATRIOVENTRICULAR JUNCTION ARRHYTHMIA; ATRIOVENTRICULAR NODAL REENTRANT TACHYCARDIA; CARDIOVASCULAR RISK; CATHETER ABLATION; CLINICAL FEATURE; COMPLETE HEART BLOCK; FEMALE; FOLLOW UP; HUMAN; MAJOR CLINICAL STUDY; MALE; OUTCOME ASSESSMENT; POWER SUPPLY; PRIORITY JOURNAL; RADIOFREQUENCY; REENTRY TACHYCARDIA; TEMPERATURE; TITRIMETRY;

EID: 59449092546     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/eun333     Document Type: Article
Times cited : (5)

References (24)
  • 1
    • 77951967808 scopus 로고    scopus 로고
    • Jackman WM, Lockwood D, Nakagawa H, Po SS, Beckman KJ, Wu R et al. Catheter ablation of atrioventricular nodal reentrant tachycardia. In Wilber DJ, Packer DL, Stevenson WG (eds). Catheter Ablation of Cardiac Arrhythmias. Basic Concepts and Clinical Applications. 3rd ed. Malden, MA: Blackwell Futura; 2008. p120-48.
    • Jackman WM, Lockwood D, Nakagawa H, Po SS, Beckman KJ, Wu R et al. Catheter ablation of atrioventricular nodal reentrant tachycardia. In Wilber DJ, Packer DL, Stevenson WG (eds). Catheter Ablation of Cardiac Arrhythmias. Basic Concepts and Clinical Applications. 3rd ed. Malden, MA: Blackwell Futura; 2008. p120-48.
  • 2
    • 0026776722 scopus 로고
    • Treatment of supraventricular tachycardia due to atrioventricular nodal reentry, by radiofrequency catheter ablation of slow-pathway conduction
    • Jackman WM, Beckman KJ, McClelland JH, Wang X, Friday KJ, Roman CA et al. Treatment of supraventricular tachycardia due to atrioventricular nodal reentry, by radiofrequency catheter ablation of slow-pathway conduction. N Engl J Med 1992;327:313-8.
    • (1992) N Engl J Med , vol.327 , pp. 313-318
    • Jackman, W.M.1    Beckman, K.J.2    McClelland, J.H.3    Wang, X.4    Friday, K.J.5    Roman, C.A.6
  • 3
    • 0026770709 scopus 로고
    • Elimination of atrioventricular nodal reentrant tachycardia using discrete slow potentials to guide application of radiofrequency energy
    • Haïssaguerre M, Gaita F, Fischer B, Commenges D, Montserrat P, d'Ivernois C et al. Elimination of atrioventricular nodal reentrant tachycardia using discrete slow potentials to guide application of radiofrequency energy. Circulation 1992;82:2162-75.
    • (1992) Circulation , vol.82 , pp. 2162-2175
    • Haïssaguerre, M.1    Gaita, F.2    Fischer, B.3    Commenges, D.4    Montserrat, P.5    d'Ivernois, C.6
  • 4
    • 0034931067 scopus 로고    scopus 로고
    • Targeting the slow pathway for atrioventricular nodal reentrant tachycardia: Initial results and long-term follow-up in 379 consecutive patients
    • Clague JR, Dagres N, Kottkamp H, Breithardt G, Borggrefe M. Targeting the slow pathway for atrioventricular nodal reentrant tachycardia: initial results and long-term follow-up in 379 consecutive patients. Eur Heart J 2001;22:82-8.
    • (2001) Eur Heart J , vol.22 , pp. 82-88
    • Clague, J.R.1    Dagres, N.2    Kottkamp, H.3    Breithardt, G.4    Borggrefe, M.5
  • 5
    • 13644256137 scopus 로고    scopus 로고
    • Selective slow pathway ablation for treatment of AV nodal reentrant tachycardia
    • Huang SK, Wilber DJ eds, Armonk, NY: Futura Publishing;
    • Taylor GW, Kay NG. Selective slow pathway ablation for treatment of AV nodal reentrant tachycardia. In Huang SK, Wilber DJ (eds). Radiofrequency Catheter Ablation of Cardiac Arrhythmias. Armonk, NY: Futura Publishing; 2000. p423-61.
    • (2000) Radiofrequency Catheter Ablation of Cardiac Arrhythmias , pp. 423-461
    • Taylor, G.W.1    Kay, N.G.2
  • 6
    • 0034131310 scopus 로고    scopus 로고
    • The NASPE prospective catheter ablation registry
    • Scheinman MM, Huang S. The NASPE prospective catheter ablation registry. Pacing Clin Electrophysiol 2000;23:1020-8.
    • (2000) Pacing Clin Electrophysiol , vol.23 , pp. 1020-1028
    • Scheinman, M.M.1    Huang, S.2
  • 7
    • 0011546915 scopus 로고    scopus 로고
    • Catheter ablation of typical atrioventricular nodal reentrant tachycardia
    • Zipes DP, Haïssaguerre M eds, 2nd ed. Armonk, NY: Futura;
    • Gaita F, Riccardi R, Marco S, Caponi D. Catheter ablation of typical atrioventricular nodal reentrant tachycardia. In Zipes DP, Haïssaguerre M (eds). Catheter Ablation of Arrhythmias. 2nd ed. Armonk, NY: Futura; 2002. p225-48.
    • (2002) Catheter Ablation of Arrhythmias , pp. 225-248
    • Gaita, F.1    Riccardi, R.2    Marco, S.3    Caponi, D.4
  • 8
    • 0346650869 scopus 로고    scopus 로고
    • Catheter ablation of atypical atrioventricular nodal reentrant tachycardia
    • Zipes DP, Haïssaguerre M eds, 2nd ed. Armonk, NY: Futura;
    • Heidbüchel H, Jackman WM. Catheter ablation of atypical atrioventricular nodal reentrant tachycardia. In Zipes DP, Haïssaguerre M (eds). Catheter Ablation of Arrhythmias. 2nd ed. Armonk, NY: Futura; 2002. p249-76.
    • (2002) Catheter Ablation of Arrhythmias , pp. 249-276
    • Heidbüchel, H.1    Jackman, W.M.2
  • 9
    • 33746390404 scopus 로고    scopus 로고
    • Radiofrequency ablation of atrioventricular nodal reentry tachycardia: A 14 year experience with 901 patients at the Tel Aviv Sourasky Medical Center
    • Topilski I, Rogowski O, Glick A, Viskin S, Eldar M, Belhassen B. Radiofrequency ablation of atrioventricular nodal reentry tachycardia: a 14 year experience with 901 patients at the Tel Aviv Sourasky Medical Center. Isr Med Assoc J 2006;8:455-9.
    • (2006) Isr Med Assoc J , vol.8 , pp. 455-459
    • Topilski, I.1    Rogowski, O.2    Glick, A.3    Viskin, S.4    Eldar, M.5    Belhassen, B.6
  • 10
    • 0031063111 scopus 로고    scopus 로고
    • Radiofrequency catheter ablation of slow pathway in 760 patients with atrioventricular nodal reentrant tachycardia - long-term results
    • Yu WC, Chen SA, Tai CT, Chiang CE, Lee SH, Chiou CW et al. Radiofrequency catheter ablation of slow pathway in 760 patients with atrioventricular nodal reentrant tachycardia - long-term results. Chin Med J (Taipei) 1997;59:71-7.
    • (1997) Chin Med J (Taipei) , vol.59 , pp. 71-77
    • Yu, W.C.1    Chen, S.A.2    Tai, C.T.3    Chiang, C.E.4    Lee, S.H.5    Chiou, C.W.6
  • 11
    • 0032935092 scopus 로고    scopus 로고
    • Catheter ablation of accessory pathways, atrioventricular nodal reentrant tachycardia, and the atrioventricular junction final results of a prospective, multicenter clinical trial
    • for the Atakr Multicenter Investigators Group
    • Calkins H, Yong P, Miller JM, Olshansky B, Carlson M, Saul JP et al. for the Atakr Multicenter Investigators Group. Catheter ablation of accessory pathways, atrioventricular nodal reentrant tachycardia, and the atrioventricular junction final results of a prospective, multicenter clinical trial. Circulation 1999;99:262-70.
    • (1999) Circulation , vol.99 , pp. 262-270
    • Calkins, H.1    Yong, P.2    Miller, J.M.3    Olshansky, B.4    Carlson, M.5    Saul, J.P.6
  • 12
    • 3142753415 scopus 로고    scopus 로고
    • Characterization of subforms of AV nodal reentrant tachycardia
    • Heidbüchel H, Jackman WM. Characterization of subforms of AV nodal reentrant tachycardia. Europace 2004;6:316-29.
    • (2004) Europace , vol.6 , pp. 316-329
    • Heidbüchel, H.1    Jackman, W.M.2
  • 13
    • 33745280599 scopus 로고    scopus 로고
    • Classification and differential diagnosis of atrioventricular nodal re-entrant tachycardia
    • Katritsis DG, Camm AJ. Classification and differential diagnosis of atrioventricular nodal re-entrant tachycardia. Europace 2006;8:29-36.
    • (2006) Europace , vol.8 , pp. 29-36
    • Katritsis, D.G.1    Camm, A.J.2
  • 15
    • 0034768924 scopus 로고    scopus 로고
    • Slow pathway modification for atrioventricular node reentrant tachycardia: Fast junctional rhythm predicts adverse prognosis
    • Lipscomb KJ, Zaidi AM, Fitzpatrick AP, Lefroy D. Slow pathway modification for atrioventricular node reentrant tachycardia: fast junctional rhythm predicts adverse prognosis. Heart 2001;85:44-7.
    • (2001) Heart , vol.85 , pp. 44-47
    • Lipscomb, K.J.1    Zaidi, A.M.2    Fitzpatrick, A.P.3    Lefroy, D.4
  • 16
    • 0027378003 scopus 로고
    • Junctional tachycardia: A useful marker during radiofrequency ablation for atrioventricular nodal reentrant tachycardia
    • Thakur RK, Klein GJ, Yee R, Stites HW. Junctional tachycardia: a useful marker during radiofrequency ablation for atrioventricular nodal reentrant tachycardia. J Am Coll Cardiol 1993;22:1706-10.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1706-1710
    • Thakur, R.K.1    Klein, G.J.2    Yee, R.3    Stites, H.W.4
  • 17
    • 0028650318 scopus 로고
    • Analysis of junctional ectopy during radiofrequency ablation of the slow pathway in patients with atrioventricular node re-entrant tachycardia
    • Jentzer J, Goyal R, Williamson B, Man KC, Niebauer M, Daoud E et al. Analysis of junctional ectopy during radiofrequency ablation of the slow pathway in patients with atrioventricular node re-entrant tachycardia. Circulation 1994;90:2820-6.
    • (1994) Circulation , vol.90 , pp. 2820-2826
    • Jentzer, J.1    Goyal, R.2    Williamson, B.3    Man, K.C.4    Niebauer, M.5    Daoud, E.6
  • 18
    • 34848863348 scopus 로고    scopus 로고
    • Catheter-induced mechanical trauma to fast and slow pathways during radiofrequency ablation of atrioventricular nodal reentry tachycardia: Incidence, predictors, and clinical implications
    • Topilski I, Rogowski O, Glick A, Viskin S, Eldar M, Belhassen B. Catheter-induced mechanical trauma to fast and slow pathways during radiofrequency ablation of atrioventricular nodal reentry tachycardia: incidence, predictors, and clinical implications. Pacing Clin Electrophysiol 2007;30:1233-41.
    • (2007) Pacing Clin Electrophysiol , vol.30 , pp. 1233-1241
    • Topilski, I.1    Rogowski, O.2    Glick, A.3    Viskin, S.4    Eldar, M.5    Belhassen, B.6
  • 19
    • 0026483408 scopus 로고
    • Transient complete heart block following percutaneous balloon pulmonary valvuloplasty: Treatment with systemic corticosteroids
    • Steinberg C, Levin AR, Engle MA. Transient complete heart block following percutaneous balloon pulmonary valvuloplasty: treatment with systemic corticosteroids. Pediatr Cardiol 1992;13:181-3.
    • (1992) Pediatr Cardiol , vol.13 , pp. 181-183
    • Steinberg, C.1    Levin, A.R.2    Engle, M.A.3
  • 20
    • 59449084190 scopus 로고
    • Complete heart block treated with corticotrophin and corticosteroid
    • Aber CP, Jones EW. Complete heart block treated with corticotrophin and corticosteroid. Br Heart J 1960;22:723-8.
    • (1960) Br Heart J , vol.22 , pp. 723-728
    • Aber, C.P.1    Jones, E.W.2
  • 22
    • 0027243867 scopus 로고
    • A randomized, prospective comparison of anterior and posterior approaches to radiofrequency catheter ablation of atrioventricular nodal reentry tachycardia
    • Langberg JJ, Leon A, Borganelli M, Kalbfleisch SJ, el-Atassi R, Calkins H et al. A randomized, prospective comparison of anterior and posterior approaches to radiofrequency catheter ablation of atrioventricular nodal reentry tachycardia. Circulation 1993;87:1551-6.
    • (1993) Circulation , vol.87 , pp. 1551-1556
    • Langberg, J.J.1    Leon, A.2    Borganelli, M.3    Kalbfleisch, S.J.4    el-Atassi, R.5    Calkins, H.6
  • 23
    • 33745248420 scopus 로고    scopus 로고
    • Long-term safety and efficacy of slow pathway ablation in patients with atrioventricular nodal re-entrant tachycardia and pre-existing prolonged PR interval
    • Pasquié JL, Scalzi J, Macia JC, Leclerq F, Grolleau-Raoux R. Long-term safety and efficacy of slow pathway ablation in patients with atrioventricular nodal re-entrant tachycardia and pre-existing prolonged PR interval. Europace 2006;8:129-33.
    • (2006) Europace , vol.8 , pp. 129-133
    • Pasquié, J.L.1    Scalzi, J.2    Macia, J.C.3    Leclerq, F.4    Grolleau-Raoux, R.5
  • 24
    • 38649134517 scopus 로고    scopus 로고
    • Cryoablation outcomes for AV nodal reentrant tachycardia comparing 4-mm versus 6-mm electrode-tip catheters
    • Rivard L, Dubuc M, Guerra PG, Novak P, Roy D, Macle L et al. Cryoablation outcomes for AV nodal reentrant tachycardia comparing 4-mm versus 6-mm electrode-tip catheters. Heart Rhythm 2008;5:230-4.
    • (2008) Heart Rhythm , vol.5 , pp. 230-234
    • Rivard, L.1    Dubuc, M.2    Guerra, P.G.3    Novak, P.4    Roy, D.5    Macle, L.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.