1
-
-
0030054293
-
The prevalence of breast implants among women in the United States
-
Cook RR, Perkins LL. The prevalence of breast implants among women in the United States. Curr Top Microbiol Immunol. 1996;210:419-425.
-
(1996)
Curr Top Microbiol Immunol
, vol.210
, pp. 419-425
-
-
Cook, R.R.1
Perkins, L.L.2
-
2
-
-
65949104471
-
-
American Society of Plastic Surgeons. Report of the 2006 Statistics: National Clearinghouse of Plastic Surgery Statistics; 2007.
-
American Society of Plastic Surgeons. Report of the 2006 Statistics: National Clearinghouse of Plastic Surgery Statistics; 2007.
-
-
-
-
3
-
-
0029130678
-
Reconstruction and the radiated breast: Is there a role for implants?
-
discussion 1116-1118
-
Evans GR, Schusterman MA, Kroll SS, et al. Reconstruction and the radiated breast: is there a role for implants? Plast Reconstr Surg. 1995;96:1111-1115; discussion 1116-1118.
-
(1995)
Plast Reconstr Surg
, vol.96
, pp. 1111-1115
-
-
Evans, G.R.1
Schusterman, M.A.2
Kroll, S.S.3
-
4
-
-
0034015956
-
Staged breast reconstruction with saline-filled implants in the irradiated breast: Recent trends and therapeutic implications
-
Spear SL, Onyewu C. Staged breast reconstruction with saline-filled implants in the irradiated breast: recent trends and therapeutic implications. Plast Reconstr Surg. 2000;105:930-942.
-
(2000)
Plast Reconstr Surg
, vol.105
, pp. 930-942
-
-
Spear, S.L.1
Onyewu, C.2
-
5
-
-
0033917434
-
Radiation therapy after immediate breast reconstruction with implants
-
discussion 59-60
-
Vandeweyer E, Deraemaecker R. Radiation therapy after immediate breast reconstruction with implants. Plast Reconstr Surg. 2000;106:56-58; discussion 59-60.
-
(2000)
Plast Reconstr Surg
, vol.106
, pp. 56-58
-
-
Vandeweyer, E.1
Deraemaecker, R.2
-
6
-
-
0035871743
-
Postmastectomy reconstruction of the previously augmented breast: Diagnosis, staging, methodology, and outcome
-
Spear SL, Slack C, Howard MA. Postmastectomy reconstruction of the previously augmented breast: diagnosis, staging, methodology, and outcome. Plast Reconstr Surg. 2001;107:1167-1176.
-
(2001)
Plast Reconstr Surg
, vol.107
, pp. 1167-1176
-
-
Spear, S.L.1
Slack, C.2
Howard, M.A.3
-
7
-
-
0037333538
-
Surgical treatment of breast cancer in previously augmented patients
-
discussion 1084-1086
-
Karanas YL, Leong DS, Da Lio A, et al. Surgical treatment of breast cancer in previously augmented patients. Plast Reconstr Surg. 2003;111: 1078-1083; discussion 1084-1086.
-
(2003)
Plast Reconstr Surg
, vol.111
, pp. 1078-1083
-
-
Karanas, Y.L.1
Leong, D.S.2
Da Lio, A.3
-
8
-
-
0035119607
-
Breast cancer after augmentation mammoplasty: Treatment by skin-sparing mastectomy and immediate reconstruction
-
Carlson GW, Moore B, Thornton JF, et al. Breast cancer after augmentation mammoplasty: treatment by skin-sparing mastectomy and immediate reconstruction. Plast Reconstr Surg. 2001;107:687-692.
-
(2001)
Plast Reconstr Surg
, vol.107
, pp. 687-692
-
-
Carlson, G.W.1
Moore, B.2
Thornton, J.F.3
-
9
-
-
0028853072
-
Analysis of explanted silicone implants: A report of 300 patients
-
discussion 6-7
-
Robinson OG Jr, Bradley EL, Wilson DS. Analysis of explanted silicone implants: a report of 300 patients. Ann Plast Surg. 1995;34:1-6; discussion 6-7.
-
(1995)
Ann Plast Surg
, vol.34
, pp. 1-6
-
-
Robinson Jr, O.G.1
Bradley, E.L.2
Wilson, D.S.3
-
10
-
-
0032446228
-
The life span of silicone gel breast implants and a comparison of mammography, ultrasonography, and magnetic resonance imaging in detecting implant rupture: A metaanalysis
-
discussion 585-586
-
Goodman CM, Cohen V, Thornby J, et al. The life span of silicone gel breast implants and a comparison of mammography, ultrasonography, and magnetic resonance imaging in detecting implant rupture: a metaanalysis. , Ann Plast Surg. 1998;41:577-585; discussion 585-586.
-
(1998)
Ann Plast Surg
, vol.41
, pp. 577-585
-
-
Goodman, C.M.1
Cohen, V.2
Thornby, J.3
-
11
-
-
0032424769
-
An analysis of silicone gel-filled breast implants: Diagnosis and failure rates
-
discussion 2309
-
Rohrich RJ, Adams WP Jr, Beran SJ, et al. An analysis of silicone gel-filled breast implants: diagnosis and failure rates. Plast Reconstr Surg. 1998;102:2304-2308; discussion 2309.
-
(1998)
Plast Reconstr Surg
, vol.102
, pp. 2304-2308
-
-
Rohrich, R.J.1
Adams Jr, W.P.2
Beran, S.J.3
-
12
-
-
0034055365
-
-
Collis N, Sharpe DT. Silicone gel-filled breast implant integrity: a retrospective review of 478 consecutively explanted implants. Plast Reconstr Surg. 2000;105:1979-1985; discussion 1986-1989.
-
Collis N, Sharpe DT. Silicone gel-filled breast implant integrity: a retrospective review of 478 consecutively explanted implants. Plast Reconstr Surg. 2000;105:1979-1985; discussion 1986-1989.
-
-
-
-
13
-
-
0033796965
-
Prevalence of rupture of silicone gel breast implants revealed on MR imaging in a population of women in Birmingham, Alabama
-
Brown SL, Middleton MS, Berg WA, et al. Prevalence of rupture of silicone gel breast implants revealed on MR imaging in a population of women in Birmingham, Alabama. AJR Am J Roentgenol. 2000;175: 1057-1064.
-
(2000)
AJR Am J Roentgenol
, vol.175
, pp. 1057-1064
-
-
Brown, S.L.1
Middleton, M.S.2
Berg, W.A.3
-
14
-
-
33746734353
-
Prevalence of rupture in inamed silicone breast implants
-
discussion 309-312
-
Heden P, Nava MB, van Tetering JP, et al. Prevalence of rupture in inamed silicone breast implants. Plast Reconstr Surg. 2006;118:303-308; discussion 309-312.
-
(2006)
Plast Reconstr Surg
, vol.118
, pp. 303-308
-
-
Heden, P.1
Nava, M.B.2
van Tetering, J.P.3
-
15
-
-
33750228628
-
Style 410 cohesive silicone breast implants: Safety and effectiveness at 5 to 9 years after implantation
-
Heden P, Bone B, Murphy DK, et al. Style 410 cohesive silicone breast implants: safety and effectiveness at 5 to 9 years after implantation. Plast Reconstr Surg. 2006;118:1281-1287.
-
(2006)
Plast Reconstr Surg
, vol.118
, pp. 1281-1287
-
-
Heden, P.1
Bone, B.2
Murphy, D.K.3
-
16
-
-
34848906013
-
Magnetic resonance imaging and explantation investigation of long-term silicone gel implant integrity
-
Collis N, Litherland J, Enion D, et al. Magnetic resonance imaging and explantation investigation of long-term silicone gel implant integrity. Plast Reconstr Surg. 2007;120:1401-1406.
-
(2007)
Plast Reconstr Surg
, vol.120
, pp. 1401-1406
-
-
Collis, N.1
Litherland, J.2
Enion, D.3
-
17
-
-
0021806886
-
Relation of free silicone to human breast carcinoma
-
Morgenstern L, Gleischman SH, Michel SL, et al. Relation of free silicone to human breast carcinoma. Arch Surg. 1985;120:573-577.
-
(1985)
Arch Surg
, vol.120
, pp. 573-577
-
-
Morgenstern, L.1
Gleischman, S.H.2
Michel, S.L.3
-
18
-
-
0028811224
-
Monitoring the axilla in patients with silicone gel implants
-
Kulber DA, Mackenzie D, Steiner JH, et al. Monitoring the axilla in patients with silicone gel implants. Ann Plast Surg. 1995;35:580-584.
-
(1995)
Ann Plast Surg
, vol.35
, pp. 580-584
-
-
Kulber, D.A.1
Mackenzie, D.2
Steiner, J.H.3
-
19
-
-
0031590624
-
Rupture of silicone-gel breast implants: Causes, sequelae, and diagnosis
-
Brown SL, Silverman BG, Berg WA. Rupture of silicone-gel breast implants: causes, sequelae, and diagnosis. Lancet. 1997;350:1531-1537.
-
(1997)
Lancet
, vol.350
, pp. 1531-1537
-
-
Brown, S.L.1
Silverman, B.G.2
Berg, W.A.3
-
20
-
-
26044464540
-
Rupture of an expander prosthesis mimics axillary cancer recurrence
-
Ismael T, Kelly J, Regan PJ. Rupture of an expander prosthesis mimics axillary cancer recurrence. Br J Plast Surg. 2005;58:1027-1028.
-
(2005)
Br J Plast Surg
, vol.58
, pp. 1027-1028
-
-
Ismael, T.1
Kelly, J.2
Regan, P.J.3
|