1
-
-
0020935749
-
-
Bannard, J.-E., O-Malley, P., 1983. The effect of ECM on the fatigue life of Co27Cr5Mo3Ni and stainless steel 316L. ISEM 7. In: Proc. of the 7th Int. Symp. on Electromachining, IFS (conferences) / CIRP, Birmingham, UK, 12.-14.4.1983, pp.443-452.
-
Bannard, J.-E., O-Malley, P., 1983. The effect of ECM on the fatigue life of Co27Cr5Mo3Ni and stainless steel 316L. ISEM 7. In: Proc. of the 7th Int. Symp. on Electromachining, IFS (conferences) / CIRP, Birmingham, UK, 12.-14.4.1983, pp.443-452.
-
-
-
-
3
-
-
59349115580
-
-
Cuddy, H., Murphy, B.P., McHugh, P.E., Quinn, D.F., 2003. Experimental analysis of the influence of grain size on the mechanical properties of thin 316L stainless steel wires for vascular stent application. In: Proceedings 18th European conference on biomaterials, Stuttgart
-
Cuddy, H., Murphy, B.P., McHugh, P.E., Quinn, D.F., 2003. Experimental analysis of the influence of grain size on the mechanical properties of thin 316L stainless steel wires for vascular stent application. In: Proceedings 18th European conference on biomaterials, Stuttgart
-
-
-
-
5
-
-
59349109217
-
-
European Parliament, 1994. The European Directive restricting the use of Nickel, Annex 1 of 76/769/EEC, June
-
European Parliament, 1994. The European Directive restricting the use of Nickel, Annex 1 of 76/769/EEC, June
-
-
-
-
7
-
-
35248840119
-
Modelling of size dependent failure in cardiovascular stent struts under tension and bending
-
Harewood F., and McHugh P.E. Modelling of size dependent failure in cardiovascular stent struts under tension and bending. Annals of Biomedical Engineering 35 9 (2007) 1539-1553
-
(2007)
Annals of Biomedical Engineering
, vol.35
, Issue.9
, pp. 1539-1553
-
-
Harewood, F.1
McHugh, P.E.2
-
8
-
-
0024444245
-
Nickel, chromium, cobalt dental alloys and allergic reactions, an overview
-
Hildebrand H.F., Veron C., and Martin P. Nickel, chromium, cobalt dental alloys and allergic reactions, an overview. Biomaterials 10 (1989) 545
-
(1989)
Biomaterials
, vol.10
, pp. 545
-
-
Hildebrand, H.F.1
Veron, C.2
Martin, P.3
-
9
-
-
59349088324
-
-
Hochörteler, G., Bernauer, J., Kriszt, K., 2000. Corrosion behaviour and nickel release of alloys with various nickel contents, in: Materials for Medical Engineering, in: Euromat 99, vol. 2, Wiley, p. 205
-
Hochörteler, G., Bernauer, J., Kriszt, K., 2000. Corrosion behaviour and nickel release of alloys with various nickel contents, in: Materials for Medical Engineering, in: Euromat 99, vol. 2, Wiley, p. 205
-
-
-
-
10
-
-
0028518120
-
Cyclic response and dislocation structures of AISI 316L stainless steel. Part 1: Single crystals fatigued at intermediate strain amplitude
-
Li Y., and Laird C. Cyclic response and dislocation structures of AISI 316L stainless steel. Part 1: Single crystals fatigued at intermediate strain amplitude. Material Science and Engineering A 186 (1994) 65
-
(1994)
Material Science and Engineering A
, vol.186
, pp. 65
-
-
Li, Y.1
Laird, C.2
-
11
-
-
0028516315
-
Cyclic response and dislocation structures of AISI 316L stainless steel. Part 2: Polycrystals fatigued at intermediate strain amplitude
-
Li Y., and Laird C. Cyclic response and dislocation structures of AISI 316L stainless steel. Part 2: Polycrystals fatigued at intermediate strain amplitude. Material Science and Engineering A 186 (1994) 87
-
(1994)
Material Science and Engineering A
, vol.186
, pp. 87
-
-
Li, Y.1
Laird, C.2
-
12
-
-
0030377529
-
High nitrogen containing Ni-free austenitic steels for medical applications
-
Menzel J., and Stein G. High nitrogen containing Ni-free austenitic steels for medical applications. ISIJ International 36 7 (1996) 893-900
-
(1996)
ISIJ International
, vol.36
, Issue.7
, pp. 893-900
-
-
Menzel, J.1
Stein, G.2
-
14
-
-
30044448844
-
The influence of grain size on the ductility of micro-scale stainless steel stent struts
-
Murphy B.P., Cuddy H., Harewood F.J., Connolley T., and McHugh P.E. The influence of grain size on the ductility of micro-scale stainless steel stent struts. Journal of Materials Science: Materials in Medicine 17 1 (2006) 1-6
-
(2006)
Journal of Materials Science: Materials in Medicine
, vol.17
, Issue.1
, pp. 1-6
-
-
Murphy, B.P.1
Cuddy, H.2
Harewood, F.J.3
Connolley, T.4
McHugh, P.E.5
-
15
-
-
59349096906
-
Stress-strain response of austenitic steel 316L in cyclic straining
-
Polak J., Hajek M., and Obrtlik K. Stress-strain response of austenitic steel 316L in cyclic straining. Metallic Materials 31 4 (1993) 198-205
-
(1993)
Metallic Materials
, vol.31
, Issue.4
, pp. 198-205
-
-
Polak, J.1
Hajek, M.2
Obrtlik, K.3
-
16
-
-
0023376758
-
Endo-prothèses coronariennes autoexpansives dans la Prévention des resténoses après angioplastie transluminale
-
Puel J., Joffre F., Rousseau H., Guermonprez B., Lancelin B., Valeix B., Imbert G., and Bounhoure J.P. Endo-prothèses coronariennes autoexpansives dans la Prévention des resténoses après angioplastie transluminale. Archives des Maladies du Coeur et des Vaisseaux (1987) 1311-1312
-
(1987)
Archives des Maladies du Coeur et des Vaisseaux
, pp. 1311-1312
-
-
Puel, J.1
Joffre, F.2
Rousseau, H.3
Guermonprez, B.4
Lancelin, B.5
Valeix, B.6
Imbert, G.7
Bounhoure, J.P.8
-
17
-
-
2942597872
-
Coronary stent strut size dependent stress-strain response investigated using micromechanical finite element models
-
Savage P., O' Donnell B.P., McHugh P.E., Murphy B.P., and Quinn D.F. Coronary stent strut size dependent stress-strain response investigated using micromechanical finite element models. Annals of Biomedical Engineering 32 2 (2004) 202-211
-
(2004)
Annals of Biomedical Engineering
, vol.32
, Issue.2
, pp. 202-211
-
-
Savage, P.1
O' Donnell, B.P.2
McHugh, P.E.3
Murphy, B.P.4
Quinn, D.F.5
-
18
-
-
15544381221
-
20. Bericht über die Leistungszahlen der Herzkatheterlabore in der Bundesrepublik Deutschland
-
van Buuren F., Mannebach H., and Horstkotte D. 20. Bericht über die Leistungszahlen der Herzkatheterlabore in der Bundesrepublik Deutschland. Z. Kardiol. 94 (2005) 212-215
-
(2005)
Z. Kardiol.
, vol.94
, pp. 212-215
-
-
van Buuren, F.1
Mannebach, H.2
Horstkotte, D.3
-
19
-
-
0021510634
-
Low cycle fatigue life enhancement of 316L stainless steel by nitrogen alloying
-
Vogt J.B., Degallaix S., and Foct J. Low cycle fatigue life enhancement of 316L stainless steel by nitrogen alloying. International Journal of Fatigue 6 4 (1984) 211-215
-
(1984)
International Journal of Fatigue
, vol.6
, Issue.4
, pp. 211-215
-
-
Vogt, J.B.1
Degallaix, S.2
Foct, J.3
-
21
-
-
59349090320
-
-
Weiß, S., Klement, U., 2004. Orientation determination on non planar surfaces. In: Proceedings of the CHANNEL Users Meeting 2004, Ribe, Denmark, Hrsg. HKL-Technology (DK), p. 62, June 9-11
-
Weiß, S., Klement, U., 2004. Orientation determination on non planar surfaces. In: Proceedings of the CHANNEL Users Meeting 2004, Ribe, Denmark, Hrsg. HKL-Technology (DK), p. 62, June 9-11
-
-
-
-
22
-
-
59349103992
-
Determination of strain components in low-cycle multiaxial fatigue tests on tubes
-
Windelband B., Schinke B., and Munz D. Determination of strain components in low-cycle multiaxial fatigue tests on tubes. International Journal of Fatigue 19 8-9 (1997) 661 A
-
(1997)
International Journal of Fatigue
, vol.19
, Issue.8-9
-
-
Windelband, B.1
Schinke, B.2
Munz, D.3
-
23
-
-
33748976954
-
A combined experimental and computational study of deformation in grains of biomedical grade 316LVM stainless steel
-
You X., Connolley T., McHugh P.E., Cuddy H., and Motz C. A combined experimental and computational study of deformation in grains of biomedical grade 316LVM stainless steel. Acta Materialia 54 (2006) 4825-4840
-
(2006)
Acta Materialia
, vol.54
, pp. 4825-4840
-
-
You, X.1
Connolley, T.2
McHugh, P.E.3
Cuddy, H.4
Motz, C.5
|