메뉴 건너뛰기




Volumn 2, Issue 2, 2009, Pages 91-96

A Prospective Feasibility Trial Investigating the Use of the Impella 2.5 System in Patients Undergoing High-Risk Percutaneous Coronary Intervention (The PROTECT I Trial). Initial U.S. Experience

(15)  Dixon, Simon R a   Henriques, José P S b   Mauri, Laura c   Sjauw, Krischan b   Civitello, Andrew d   Kar, Biswajit d   Loyalka, Pranav d   Resnic, Frederic S c   Teirstein, Paul e   Makkar, Raj f   Palacios, Igor F g   Collins, Michael h   Moses, Jeffrey h   Benali, Karim i   O'Neill, William W j  


Author keywords

circulatory support; high risk; percutaneous coronary intervention

Indexed keywords

ADULT; AGED; ARTICLE; ASSISTED CIRCULATION; CARDIOGENIC SHOCK; CLINICAL ARTICLE; CLINICAL TRIAL; CORONARY ARTERY; DISEASE SEVERITY; FEASIBILITY STUDY; FEMALE; HEART ASSIST DEVICE; HEART HEMODYNAMICS; HEART INFARCTION; HEART LEFT VENTRICLE; HEART LEFT VENTRICLE EJECTION FRACTION; HEMOLYSIS; HIGH RISK PATIENT; HUMAN; MALE; MEAN ARTERIAL PRESSURE; MULTICENTER STUDY; PERCUTANEOUS CORONARY INTERVENTION; PRIORITY JOURNAL; PROSPECTIVE STUDY; SAFETY; ST SEGMENT ELEVATION; SYSTEMIC CIRCULATION; BODY MASS; CORONARY ARTERY DISEASE; HEART LEFT VENTRICLE FUNCTION; HEART STROKE VOLUME; HEMODYNAMICS; MIDDLE AGED; RISK ASSESSMENT; RISK FACTOR; TRANSLUMINAL CORONARY ANGIOPLASTY; UNITED STATES; VERY ELDERLY;

EID: 59149096411     PISSN: 19368798     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcin.2008.11.005     Document Type: Article
Times cited : (294)

References (7)
  • 1
    • 0037414073 scopus 로고    scopus 로고
    • Left ventricular support by catheter-mounted axial flow pump reduces infarct size
    • Meyns B., Stolinski J., Leunens V., et al. Left ventricular support by catheter-mounted axial flow pump reduces infarct size. J Am Coll Cardiol 41 (2003) 1087-1095
    • (2003) J Am Coll Cardiol , vol.41 , pp. 1087-1095
    • Meyns, B.1    Stolinski, J.2    Leunens, V.3
  • 2
    • 20344383754 scopus 로고    scopus 로고
    • Left ventricular unloading and concomitant total cardiac output increase by the use of percutaneous Impella Recover LP 2.5 assist device during high-risk coronary intervention
    • Valgimigli M., Steendijk P., Sianos G., et al. Left ventricular unloading and concomitant total cardiac output increase by the use of percutaneous Impella Recover LP 2.5 assist device during high-risk coronary intervention. Cathet Cardiovasc Interv 65 (2005) 263-267
    • (2005) Cathet Cardiovasc Interv , vol.65 , pp. 263-267
    • Valgimigli, M.1    Steendijk, P.2    Sianos, G.3
  • 3
    • 35348966944 scopus 로고    scopus 로고
    • Effects of left ventricular unloading by Impella Recover LP 2.5 on coronary hemodynamics
    • Remmelink M., Sjauw K.D., Henriques J.P., et al. Effects of left ventricular unloading by Impella Recover LP 2.5 on coronary hemodynamics. Cathet Cardiovasc Interv 70 (2007) 532-537
    • (2007) Cathet Cardiovasc Interv , vol.70 , pp. 532-537
    • Remmelink, M.1    Sjauw, K.D.2    Henriques, J.P.3
  • 4
    • 12144290848 scopus 로고    scopus 로고
    • The Impella Recover microaxial left ventricular assist device reduces mortality for postcardiotomy failure: a three-center experience
    • Siegenthaler M.P., Brehm K., Strecker T., et al. The Impella Recover microaxial left ventricular assist device reduces mortality for postcardiotomy failure: a three-center experience. J Thorac Cardiovasc Surg 127 (2004) 812-822
    • (2004) J Thorac Cardiovasc Surg , vol.127 , pp. 812-822
    • Siegenthaler, M.P.1    Brehm, K.2    Strecker, T.3
  • 5
    • 16544367875 scopus 로고    scopus 로고
    • Impella Recover 100: successful perioperative support for off pump coronary artery bypass grafting surgery in a patient with end-stage ischemic cardiomyopathy
    • Strecker T., Fischlein T., and Pfeiffer S. Impella Recover 100: successful perioperative support for off pump coronary artery bypass grafting surgery in a patient with end-stage ischemic cardiomyopathy. J Cardiovasc Surg 45 (2004) 381-384
    • (2004) J Cardiovasc Surg , vol.45 , pp. 381-384
    • Strecker, T.1    Fischlein, T.2    Pfeiffer, S.3
  • 6
    • 0346788735 scopus 로고    scopus 로고
    • Initial experiences with the Impella device in patients with cardiogenic shock-Impella support for cardiogenic shock
    • Meyns B., Dens J., Sergeant P., et al. Initial experiences with the Impella device in patients with cardiogenic shock-Impella support for cardiogenic shock. Thorac Cardiovasc Surg 51 (2003) 312-317
    • (2003) Thorac Cardiovasc Surg , vol.51 , pp. 312-317
    • Meyns, B.1    Dens, J.2    Sergeant, P.3
  • 7
    • 33645082957 scopus 로고    scopus 로고
    • Safety and feasibility of elective high-risk percutaneous coronary intervention procedures with left ventricular support of the Impella Recover LP 2.5
    • Henriques J.P.S., Remmelink M., Baan J., et al. Safety and feasibility of elective high-risk percutaneous coronary intervention procedures with left ventricular support of the Impella Recover LP 2.5. Am J Cardiol 97 (2006) 990-992
    • (2006) Am J Cardiol , vol.97 , pp. 990-992
    • Henriques, J.P.S.1    Remmelink, M.2    Baan, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.