-
1
-
-
0003413171
-
-
Kohn L, Corrigan J, Donaldson M, editors, Washington, DC: National Academy Press
-
Kohn L, Corrigan J, Donaldson M, editors. To err is human: building a safer health system. Washington, DC: National Academy Press, 1999.
-
(1999)
To err is human: Building a safer health system
-
-
-
3
-
-
10044274337
-
Medical errors: An introduction to concepts
-
Kalra J. Medical errors: an introduction to concepts. Clin Biochem 2004;37:1043-51.
-
(2004)
Clin Biochem
, vol.37
, pp. 1043-1051
-
-
Kalra, J.1
-
4
-
-
10044255447
-
Medical errors: Impact on clinical laboratories and other critical areas
-
Kalra J. Medical errors: impact on clinical laboratories and other critical areas. Clin Biochem 2004;37:1052-62.
-
(2004)
Clin Biochem
, vol.37
, pp. 1052-1062
-
-
Kalra, J.1
-
5
-
-
10044278164
-
Medical errors: Overcoming the challenges
-
Kalra J. Medical errors: overcoming the challenges. Clin Biochem 2004;37:1063-71.
-
(2004)
Clin Biochem
, vol.37
, pp. 1063-1071
-
-
Kalra, J.1
-
6
-
-
85047687808
-
Classifying laboratory incident reports to identify problems that jeopardize patient safety
-
Astion ML, Shojania KG, Hamill TR, Kim S, Ng VL. Classifying laboratory incident reports to identify problems that jeopardize patient safety. Am J Clin Pathol 2003;120:18-26.
-
(2003)
Am J Clin Pathol
, vol.120
, pp. 18-26
-
-
Astion, M.L.1
Shojania, K.G.2
Hamill, T.R.3
Kim, S.4
Ng, V.L.5
-
7
-
-
0024316158
-
Unreliable visual estimation of the incidence and amount of turbidity, hemolysis, and icterus in serum from hospitalized patients
-
Glick MR, Ryder KW, Glick SJ, Woods JR. Unreliable visual estimation of the incidence and amount of turbidity, hemolysis, and icterus in serum from hospitalized patients. Clin Chem 1989;35:837-9.
-
(1989)
Clin Chem
, vol.35
, pp. 837-839
-
-
Glick, M.R.1
Ryder, K.W.2
Glick, S.J.3
Woods, J.R.4
-
8
-
-
0025906811
-
Incidence and amount of turbidity, hemolysis, and icterus in serum from outpatients
-
Ryder KW, Glick MR, Glick SJ. Incidence and amount of turbidity, hemolysis, and icterus in serum from outpatients. Lab Med 1991;22:415-8.
-
(1991)
Lab Med
, vol.22
, pp. 415-418
-
-
Ryder, K.W.1
Glick, M.R.2
Glick, S.J.3
-
9
-
-
0024596652
-
Serum-Index und Interferogramm - Ein neuer Weg zur Prüfung und Darstellung von Interferenzen durch Serumchromogene.
-
Sonntag O, Glick MR. Serum-Index und Interferogramm - Ein neuer Weg zur Prüfung und Darstellung von Interferenzen durch Serumchromogene. Lab Med 1989;13:77-82.
-
(1989)
Lab Med
, vol.13
, pp. 77-82
-
-
Sonntag, O.1
Glick, M.R.2
-
10
-
-
27644507273
-
Practical uses of serum indices to reduce errors from lipemia, icterus, and hemolysis. [Abstract 262]
-
Glick MR, Ryder KW, Vroon DH, Masters BE, Sonntag O. Practical uses of serum indices to reduce errors from lipemia, icterus, and hemolysis. [Abstract 262]. Clin Chem 1990;36:1008.
-
(1990)
Clin Chem
, vol.36
, pp. 1008
-
-
Glick, M.R.1
Ryder, K.W.2
Vroon, D.H.3
Masters, B.E.4
Sonntag, O.5
-
11
-
-
0036729269
-
Discrepancy between visual and spectrophotometric assessment of sample haemolysis
-
Hawkins RC. Discrepancy between visual and spectrophotometric assessment of sample haemolysis. Ann Clin Biochem 2002;39:521-2.
-
(2002)
Ann Clin Biochem
, vol.39
, pp. 521-522
-
-
Hawkins, R.C.1
-
12
-
-
59049092066
-
Visual vs. automated estimation of hemolysis, icterus and turbidity [Abstract A-160]
-
Onifade K, Morgan B, Harris P, Billings K, Mohammad A, Petersen J, Okorodudu AO. Visual vs. automated estimation of hemolysis, icterus and turbidity [Abstract A-160]. Clin Chem 2005;51:A51.
-
(2005)
Clin Chem
, vol.51
-
-
Onifade, K.1
Morgan, B.2
Harris, P.3
Billings, K.4
Mohammad, A.5
Petersen, J.6
Okorodudu, A.O.7
-
13
-
-
0037256782
-
The influence of hemolysis, turbidity and icterus on the measurements of CK-MB, troponin I and myoglobin
-
Kwon HJ, Seo EJ, Min KO. The influence of hemolysis, turbidity and icterus on the measurements of CK-MB, troponin I and myoglobin. Clin Chem Lab Med 2003;41:360-4.
-
(2003)
Clin Chem Lab Med
, vol.41
, pp. 360-364
-
-
Kwon, H.J.1
Seo, E.J.2
Min, K.O.3
-
14
-
-
14944352962
-
Poor knowledge and faulty thinking regarding hemolysis and potassium elevation
-
Hawkins RC. Poor knowledge and faulty thinking regarding hemolysis and potassium elevation. Clin Chem Lab Med 2005;43:216-20.
-
(2005)
Clin Chem Lab Med
, vol.43
, pp. 216-220
-
-
Hawkins, R.C.1
-
15
-
-
84941841395
-
Haemolysis as an interference factor in clinical chemistry
-
Sonntag O. Haemolysis as an interference factor in clinical chemistry. J Clin Chem Clin Biochem 1986;24:127-39.
-
(1986)
J Clin Chem Clin Biochem
, vol.24
, pp. 127-139
-
-
Sonntag, O.1
-
17
-
-
7044241205
-
Evaluating interference caused by lipemia
-
Kroll MH. Evaluating interference caused by lipemia. Clin Chem 2004;50:1968-9.
-
(2004)
Clin Chem
, vol.50
, pp. 1968-1969
-
-
Kroll, M.H.1
-
18
-
-
7044260841
-
Assay-specific differences in lipemic interference in native and intralipid-supplemented samples
-
Bornhorst JA, Roberts RF, Roberts WL. Assay-specific differences in lipemic interference in native and intralipid-supplemented samples. Clin Chem 2004;50:2197-201.
-
(2004)
Clin Chem
, vol.50
, pp. 2197-2201
-
-
Bornhorst, J.A.1
Roberts, R.F.2
Roberts, W.L.3
-
19
-
-
0033972513
-
Hemolyzed specimens: A reason for rejection or a clinical challenge?
-
Carraro P, Servidio G, Plebani M. Hemolyzed specimens: a reason for rejection or a clinical challenge? Clin Chem 2000;46:306-7.
-
(2000)
Clin Chem
, vol.46
, pp. 306-307
-
-
Carraro, P.1
Servidio, G.2
Plebani, M.3
-
20
-
-
17144371015
-
Correction and reporting of potassium results in haemolysed samples
-
Dimeski G, Clague AE, Hickman PE. Correction and reporting of potassium results in haemolysed samples. Ann Clin Biochem 2005;42:119-23.
-
(2005)
Ann Clin Biochem
, vol.42
, pp. 119-123
-
-
Dimeski, G.1
Clague, A.E.2
Hickman, P.E.3
-
21
-
-
0025346148
-
Interference by haemolysis, icterus and lipaemia in assays on the Beckman Synchron CX5 and methods for correction
-
Randall AG, Garcia-Webb P, Beilby JP. Interference by haemolysis, icterus and lipaemia in assays on the Beckman Synchron CX5 and methods for correction. Ann Clin Biochem 1990;27:345-52.
-
(1990)
Ann Clin Biochem
, vol.27
, pp. 345-352
-
-
Randall, A.G.1
Garcia-Webb, P.2
Beilby, J.P.3
-
22
-
-
0027171503
-
Characterization and mathematical correction of hemolysis interference in selected Hitachi 717 assays
-
Jay DW, Provasek D. Characterization and mathematical correction of hemolysis interference in selected Hitachi 717 assays. Clin Chem 1993;39:1804-10.
-
(1993)
Clin Chem
, vol.39
, pp. 1804-1810
-
-
Jay, D.W.1
Provasek, D.2
-
23
-
-
0242659853
-
Unreliability of triglyceride measurement to predict turbidity induced interference
-
Twomey PJ, Don-Wauchope AC, McCullough D. Unreliability of triglyceride measurement to predict turbidity induced interference. J Clin Pathol 2003;56:861-2.
-
(2003)
J Clin Pathol
, vol.56
, pp. 861-862
-
-
Twomey, P.J.1
Don-Wauchope, A.C.2
McCullough, D.3
-
24
-
-
0033798463
-
The haemolytic, icteric and lipemic sample - recommendations regarding their recognition and prevention of clinically relevant interferences
-
Guder WG, da Fonseca-Wollheim F, Heil W, Schmitt YM, Töpfer G, Wisser H, Zawta B. The haemolytic, icteric and lipemic sample - recommendations regarding their recognition and prevention of clinically relevant interferences. J Lab Med 2000;24:357-64.
-
(2000)
J Lab Med
, vol.24
, pp. 357-364
-
-
Guder, W.G.1
da Fonseca-Wollheim, F.2
Heil, W.3
Schmitt, Y.M.4
Töpfer, G.5
Wisser, H.6
Zawta, B.7
-
25
-
-
0027507014
-
Erroneous laboratory results from hemolyzed, icteric, and lipemic specimens
-
Ryder KW, Glick MR. Erroneous laboratory results from hemolyzed, icteric, and lipemic specimens. Clin Chem 1993;39:175-6.
-
(1993)
Clin Chem
, vol.39
, pp. 175-176
-
-
Ryder, K.W.1
Glick, M.R.2
-
26
-
-
0023626103
-
Analytical systems ranked by freedom from interferences
-
Glick MR, Ryder KW. Analytical systems ranked by freedom from interferences. Clin Chem 1987;33:1453-8.
-
(1987)
Clin Chem
, vol.33
, pp. 1453-1458
-
-
Glick, M.R.1
Ryder, K.W.2
-
27
-
-
0027930485
-
Enzymatic determination of sodium, potassium, and chloride in abnormal (hemolyzed, icteric, lipemic, paraproteinemic, or uremic) serum samples compared with indirect determination with ion-selective electrodes
-
Hübl W, Wejbora R, Shafti-Keramat I, Haider A, Hajdusich P, Bayer PM. Enzymatic determination of sodium, potassium, and chloride in abnormal (hemolyzed, icteric, lipemic, paraproteinemic, or uremic) serum samples compared with indirect determination with ion-selective electrodes. Clin Chem 1994;40:1528-31.
-
(1994)
Clin Chem
, vol.40
, pp. 1528-1531
-
-
Hübl, W.1
Wejbora, R.2
Shafti-Keramat, I.3
Haider, A.4
Hajdusich, P.5
Bayer, P.M.6
-
28
-
-
0026337984
-
Serum index identifies lipemic samples causing interference with bilirubin assay on Hitachi 717
-
Pearson JR, Wells R, Wells A. Serum index identifies lipemic samples causing interference with bilirubin assay on Hitachi 717. Clin Chem 1991;37:2014-5.
-
(1991)
Clin Chem
, vol.37
, pp. 2014-2015
-
-
Pearson, J.R.1
Wells, R.2
Wells, A.3
-
29
-
-
0025301326
-
Storende invloeden van hemolyse, lipemie en bilirubine op 22 routine-chemie-bepalingen: Het gebruik van serumindices onderzocht op de Hitachi 717.
-
Bakkeren DL, van den Bergh FAJTM. Storende invloeden van hemolyse, lipemie en bilirubine op 22 routine-chemie-bepalingen: het gebruik van serumindices onderzocht op de Hitachi 717. Tijdschr NVKC 1990;15:152-7.
-
(1990)
Tijdschr NVKC
, vol.15
, pp. 152-157
-
-
Bakkeren, D.L.1
van den Bergh, F.A.J.T.M.2
-
30
-
-
0025600821
-
A multicenter evaluation of the Boehringer Mannheim Hitachi 717 system
-
Flood J, Liedtke R, Mattenheimer H, Rothouse L, Trundle D, Vronn D, et al. A multicenter evaluation of the Boehringer Mannheim Hitachi 717 system. Clin Chem 1990;23:477-88.
-
(1990)
Clin Chem
, vol.23
, pp. 477-488
-
-
Flood, J.1
Liedtke, R.2
Mattenheimer, H.3
Rothouse, L.4
Trundle, D.5
Vronn, D.6
-
31
-
-
11144334591
-
Automated processing of serum indices used for interference detection by the laboratory information system
-
Vermeer HJ, Thomassen E, de Jonge N. Automated processing of serum indices used for interference detection by the laboratory information system. Clin Chem 2005;51:244-7.
-
(2005)
Clin Chem
, vol.51
, pp. 244-247
-
-
Vermeer, H.J.1
Thomassen, E.2
de Jonge, N.3
-
32
-
-
59049091526
-
-
Warren K, Sawyer B, Cheehan T, Merrill G, Mehalek G, Li C, Least Jr C. Interference evaluation of the VITROS 5,1 FS chemistry system MicroSensor (sample integrity) module [Abstract A55]. Clin Chem 2002;48:6.
-
Warren K, Sawyer B, Cheehan T, Merrill G, Mehalek G, Li C, Least Jr C. Interference evaluation of the VITROS 5,1 FS chemistry system MicroSensor (sample integrity) module [Abstract A55]. Clin Chem 2002;48:6.
-
-
-
-
33
-
-
59049099934
-
Analyte-specific specimen quality measurement with the VITROS 5,1 FS chemistry system [Abstract M-131]
-
Douglas L, Love J, Mehalek G, Sawyer B, Steelman M. Analyte-specific specimen quality measurement with the VITROS 5,1 FS chemistry system [Abstract M-131]. Clin Chem Lab Med 2003;41(Suppl 116):5116.
-
(2003)
Clin Chem Lab Med
, vol.41
, Issue.SUPPL. 116
, pp. 5116
-
-
Douglas, L.1
Love, J.2
Mehalek, G.3
Sawyer, B.4
Steelman, M.5
-
34
-
-
0002427925
-
A method for the determination of hemoglobin in plasma by near ultraviolet spectrophotometry
-
Harboe M. A method for the determination of hemoglobin in plasma by near ultraviolet spectrophotometry. Scand J Clin Lab Invest 1959;11:66-70.
-
(1959)
Scand J Clin Lab Invest
, vol.11
, pp. 66-70
-
-
Harboe, M.1
-
35
-
-
0021045350
-
A new biometrical procedure for testing the equality of measurements from two different analytical methods
-
Passing H, Bablok W. A new biometrical procedure for testing the equality of measurements from two different analytical methods. J Clin Chem Clin Biochem 1983;21:709-20.
-
(1983)
J Clin Chem Clin Biochem
, vol.21
, pp. 709-720
-
-
Passing, H.1
Bablok, W.2
-
36
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;307-10.
-
(1986)
Lancet
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
|