Volumn 31, Issue 2, 2009, Pages 227-233

Influence of antegrade pulmonary blood flow on the hemodynamic performance of bidirectional cavopulmonary anastomosis: A numerical study

Author keywords

Antegrade pulmonary blood flow; Bidirectional cavopulmonary anastomosis; Computational fluid dynamics; CT

Indexed keywords

ANTEGRADE PULMONARY BLOOD FLOW; BIDIRECTIONAL CAVOPULMONARY ANASTOMOSIS; CARDIAC CYCLES; CFD SIMULATIONS; CONTROL VOLUMES; CT; FLOW RATIOS; FLUID STRUCTURES; MEAN FLOWS; NUMERICAL STUDIES; POWER LOSS; PULMONARY ARTERIES; PULSATILITY; SUPERIOR VENA CAVA; THREE-DIMENSIONAL GEOMETRIES;

EID: 59049094530     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.medengphy.2008.07.004     Document Type: Article
Times cited : (12)

References (18)
  • 1
    • 0025043789 scopus 로고
    • Bidirectional cavopulmonary anastomosis as interim palliation for high-risk Fontan candidates. Early results
    • Bridges N.D., Jonas R.A., Mayer J.E., Flanagan M.F., Keane J.F., and Castaneda A.R. Bidirectional cavopulmonary anastomosis as interim palliation for high-risk Fontan candidates. Early results. Circulation 82 Suppl. 5 (1990) 170-176
    • (1990) Circulation , vol.82 , Issue.SUPPL. 5 , pp. 170-176
    • Bridges, N.D.1    Jonas, R.A.2    Mayer, J.E.3    Flanagan, M.F.4    Keane, J.F.5    Castaneda, A.R.6
  • 2
    • 0041657410 scopus 로고    scopus 로고
    • Ventricular mechanics in the bidirectional Glenn procedure and total cavopulmonary connection
    • Tanoue Y., Sese A., Imoto Y., and Joh K. Ventricular mechanics in the bidirectional Glenn procedure and total cavopulmonary connection. Ann Thorac Surg 76 (2003) 562-566
    • (2003) Ann Thorac Surg , vol.76 , pp. 562-566
    • Tanoue, Y.1    Sese, A.2    Imoto, Y.3    Joh, K.4
  • 3
    • 0035335994 scopus 로고    scopus 로고
    • Bidirectional Glenn procedure improves the mechanical efficiency of a total cavopulmonary connection in high-risk Fontan candidates
    • Tanoue Y., Sese A., Ueno Y., Joh K., and Hijii T. Bidirectional Glenn procedure improves the mechanical efficiency of a total cavopulmonary connection in high-risk Fontan candidates. Circulation 103 (2001) 2176-2180
    • (2001) Circulation , vol.103 , pp. 2176-2180
    • Tanoue, Y.1    Sese, A.2    Ueno, Y.3    Joh, K.4    Hijii, T.5
  • 4
    • 23944469367 scopus 로고    scopus 로고
    • Appropriate additional pulmonary blood flow at the bidirectional Glenn procedure is useful for completion of total cavopulmonary connection
    • Yoshida M., Yamaguchi M., Yoshimura N., Murakami H., Matsuhisa H., and Okita Y. Appropriate additional pulmonary blood flow at the bidirectional Glenn procedure is useful for completion of total cavopulmonary connection. Ann Thorac Surg 80 (2005) 976-981
    • (2005) Ann Thorac Surg , vol.80 , pp. 976-981
    • Yoshida, M.1    Yamaguchi, M.2    Yoshimura, N.3    Murakami, H.4    Matsuhisa, H.5    Okita, Y.6
  • 6
    • 34548027722 scopus 로고    scopus 로고
    • Persistent antegrade pulmonary blood flow post-Glenn does not alter early post-Fontan outcomes in single-ventricle patients
    • Gray R.G., Altmann K., Mosca R.S., Prakash A., Williams I.A., Quaegebeur J.M., et al. Persistent antegrade pulmonary blood flow post-Glenn does not alter early post-Fontan outcomes in single-ventricle patients. Ann Thorac Surg 84 (2007) 888-893
    • (2007) Ann Thorac Surg , vol.84 , pp. 888-893
    • Gray, R.G.1    Altmann, K.2    Mosca, R.S.3    Prakash, A.4    Williams, I.A.5    Quaegebeur, J.M.6
  • 7
    • 11144263752 scopus 로고    scopus 로고
    • Additional pulmonary blood flow has no adverse effect on outcome after bidirectional cavopulmonary anastomosis
    • Berdat P.A., Belli E., Lacour-Gayet F., Planché C., and Serraf A. Additional pulmonary blood flow has no adverse effect on outcome after bidirectional cavopulmonary anastomosis. Ann Thorac Surg 79 (2005) 29-36
    • (2005) Ann Thorac Surg , vol.79 , pp. 29-36
    • Berdat, P.A.1    Belli, E.2    Lacour-Gayet, F.3    Planché, C.4    Serraf, A.5
  • 8
    • 0028848384 scopus 로고
    • Bidirectional Glenn. Is accessory pulmonary blood flow good or bad?
    • Mainwaring R.D., Lamberti J.J., Uzark K., and Spicer R.L. Bidirectional Glenn. Is accessory pulmonary blood flow good or bad?. Circulation 92 Suppl. 9 (1995) 294-297
    • (1995) Circulation , vol.92 , Issue.SUPPL. 9 , pp. 294-297
    • Mainwaring, R.D.1    Lamberti, J.J.2    Uzark, K.3    Spicer, R.L.4
  • 10
    • 20344386713 scopus 로고    scopus 로고
    • The clinical impact of antegrade pulmonary blood flow on the bidirectional cavopulmonary shunt in infants
    • Migliazza L., Seddio F., Annecchino F.P., and Crupi G. The clinical impact of antegrade pulmonary blood flow on the bidirectional cavopulmonary shunt in infants. Cardiol Young 14 Suppl. 3 (2004) 44-47
    • (2004) Cardiol Young , vol.14 , Issue.SUPPL. 3 , pp. 44-47
    • Migliazza, L.1    Seddio, F.2    Annecchino, F.P.3    Crupi, G.4
  • 11
    • 10944230387 scopus 로고    scopus 로고
    • The effects of different mesh generation methods on computational fluid dynamic analysis and power loss assessment in total cavopulmonary connection
    • Liu Y., Pekkan K., Jones S.C., and Yoganathan A.P. The effects of different mesh generation methods on computational fluid dynamic analysis and power loss assessment in total cavopulmonary connection. J Biomech Eng 126 (2004) 594-603
    • (2004) J Biomech Eng , vol.126 , pp. 594-603
    • Liu, Y.1    Pekkan, K.2    Jones, S.C.3    Yoganathan, A.P.4
  • 12
    • 0030297638 scopus 로고    scopus 로고
    • A computational pulsatile model of the bidirectional cavopulmonary anastomosis: the influence of pulmonary forward flow
    • Migliavacca F., de Leval M.R., Dubini G., and Pietrabissa R. A computational pulsatile model of the bidirectional cavopulmonary anastomosis: the influence of pulmonary forward flow. J Biomech Eng 118 (1996) 520-528
    • (1996) J Biomech Eng , vol.118 , pp. 520-528
    • Migliavacca, F.1    de Leval, M.R.2    Dubini, G.3    Pietrabissa, R.4
  • 13
    • 0742306283 scopus 로고    scopus 로고
    • Computational fluid dynamics simulations in realistic 3-D geometries of the total cavopulmonary anastomosis: the influence of the inferior caval anastomosis
    • Migliavacca F., Dubini G., Bove E.L., and de Leval M.R. Computational fluid dynamics simulations in realistic 3-D geometries of the total cavopulmonary anastomosis: the influence of the inferior caval anastomosis. J Biomech Eng 125 (2003) 805-813
    • (2003) J Biomech Eng , vol.125 , pp. 805-813
    • Migliavacca, F.1    Dubini, G.2    Bove, E.L.3    de Leval, M.R.4
  • 14
    • 17444368111 scopus 로고    scopus 로고
    • Physics-driven CFD modeling of complex anatomical cardiovascular flows-a TCPC case study
    • Pekkan K., de Zélicourt D., Ge L., Sotiropoulos F., Frakes D., Fogel M.A., et al. Physics-driven CFD modeling of complex anatomical cardiovascular flows-a TCPC case study. Ann Biomed Eng 33 (2005) 284-300
    • (2005) Ann Biomed Eng , vol.33 , pp. 284-300
    • Pekkan, K.1    de Zélicourt, D.2    Ge, L.3    Sotiropoulos, F.4    Frakes, D.5    Fogel, M.A.6
  • 15
    • 0344665461 scopus 로고    scopus 로고
    • Effects of controlled antegrade pulmonary blood flow on cardiac function after bidirectional cavopulmonary anastomosis
    • Caspi J., Pettitt T.W., Ferguson Jr. T.B., Stopa A.R., and Sandhu S.K. Effects of controlled antegrade pulmonary blood flow on cardiac function after bidirectional cavopulmonary anastomosis. Ann Thorac Surg 76 (2003) 1917-1921
    • (2003) Ann Thorac Surg , vol.76 , pp. 1917-1921
    • Caspi, J.1    Pettitt, T.W.2    Ferguson Jr., T.B.3    Stopa, A.R.4    Sandhu, S.K.5
  • 17
    • 0035384387 scopus 로고    scopus 로고
    • Bidirectional cavopulmonary shunt with right ventricular outflow patency: the impact of pulsatility on pulmonary endothelial function
    • Kurotobi S., Sano T., Kogaki S., Matsushita T., Miwatani T., Takeuchi M., et al. Bidirectional cavopulmonary shunt with right ventricular outflow patency: the impact of pulsatility on pulmonary endothelial function. J Thorac Cardiovasc Surg 121 (2001) 1161-1168
    • (2001) J Thorac Cardiovasc Surg , vol.121 , pp. 1161-1168
    • Kurotobi, S.1    Sano, T.2    Kogaki, S.3    Matsushita, T.4    Miwatani, T.5    Takeuchi, M.6
  • 18
    • 0029932469 scopus 로고    scopus 로고
    • Use of computational fluid dynamics in the design of surgical procedures: application to the study of competitive flows in cavo-pulmonary connections
    • de Leval M.R., Dubini G., Migliavacca F., Jalali H., Camporini G., Redington A., et al. Use of computational fluid dynamics in the design of surgical procedures: application to the study of competitive flows in cavo-pulmonary connections. J Thorac Cardiovasc Surg 111 (1996) 502-513
    • (1996) J Thorac Cardiovasc Surg , vol.111 , pp. 502-513
    • de Leval, M.R.1    Dubini, G.2    Migliavacca, F.3    Jalali, H.4    Camporini, G.5    Redington, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.