메뉴 건너뛰기




Volumn , Issue , 2008, Pages 19-33

Dual source CT technology

Author keywords

[No Author keywords available]

Indexed keywords


EID: 58949088913     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1007/978-3-540-77602-4_1     Document Type: Chapter
Times cited : (12)

References (31)
  • 1
    • 0025221610 scopus 로고
    • Computed tomography scanning with simultaneous patient translation
    • Crawford, C. R., and K. F. King. Computed tomography scanning with simultaneous patient translation. Med Phys 1990;17;967-82
    • (1990) Med Phys , vol.17 , pp. 967-982
    • Crawford, C.R.1    King, K.F.2
  • 2
    • 0025351273 scopus 로고
    • Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation
    • Kalender, W. A., W. Seissler, E. Klotz, et al. Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation. Radiology 1990;176;181-3
    • (1990) Radiology , vol.176 , pp. 181-183
    • Kalender, W.A.1    Seissler, W.2    Klotz, E.3
  • 3
    • 0029612812 scopus 로고
    • Thin-section three-dimensional spiral CT: Is isotropic imaging possible?
    • Kalender, W. A. Thin-section three-dimensional spiral CT: is isotropic imaging possible? Radiology 1995;197;578-80
    • (1995) Radiology , vol.197 , pp. 578-580
    • Kalender, W.A.1
  • 4
    • 0034069213 scopus 로고    scopus 로고
    • Four multidetector-row helical CT: Image quality and volume coverage speed
    • Hu, H., H. D. He, W. D. Foley, et al. Four multidetector-row helical CT: image quality and volume coverage speed. Radiology 2000;215;55-62
    • (2000) Radiology , vol.215 , pp. 55-62
    • Hu, H.1    He, H.D.2    Foley, W.D.3
  • 5
    • 0033180517 scopus 로고    scopus 로고
    • Subsecond multi-slice computed tomography: Basics and applications
    • Klingenbeck-Regn, K., S. Schaller, T. Flohr, et al. Subsecond multi-slice computed tomography: basics and applications. Eur J Radiol 1999;31;110-24
    • (1999) Eur J Radiol , vol.31 , pp. 110-124
    • Klingenbeck-Regn, K.1    Schaller, S.2    Flohr, T.3
  • 6
    • 0032718470 scopus 로고    scopus 로고
    • Performance evaluation of a multislice CT system
    • McCollough, C. H., and F. E. Zink. Performance evaluation of a multislice CT system. Med Phys 1999;26;2223-30
    • (1999) Med Phys , vol.26 , pp. 2223-2230
    • McCollough, C.H.1    Zink, F.E.2
  • 7
    • 0034835414 scopus 로고    scopus 로고
    • Multi-detector row CT angiography of lower extremity arterial inflow and runoff: Initial experience
    • Rubin, G. D., A. J. Schmidt, L. J. Logan, et al. Multi-detector row CT angiography of lower extremity arterial inflow and runoff: initial experience. Radiology 2001;221;146-58
    • (2001) Radiology , vol.221 , pp. 146-158
    • Rubin, G.D.1    Schmidt, A.J.2    Logan, L.J.3
  • 8
    • 0033863629 scopus 로고    scopus 로고
    • ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart
    • Kachelriess, M., S. Ulzheimer, and W. A. Kalender. ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart. Med Phys 2000;27;1881-902
    • (2000) Med Phys , vol.27 , pp. 1881-1902
    • Kachelriess, M.1    Ulzheimer, S.2    Kalender, W.A.3
  • 9
    • 0033753104 scopus 로고    scopus 로고
    • Cardiac imaging by means of electrocardiographically gated multisection spiral CT: Initial experience
    • Ohnesorge, B., T. Flohr, C. Becker, et al. Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. Radiology 2000;217;564-71
    • (2000) Radiology , vol.217 , pp. 564-571
    • Ohnesorge, B.1    Flohr, T.2    Becker, C.3
  • 10
    • 0035941737 scopus 로고    scopus 로고
    • Coronary angiography with multi-slice computed tomography
    • Nieman, K., M. Oudkerk, B. J. Rensing, et al. Coronary angiography with multi-slice computed tomography. Lancet 2001;357;599-603
    • (2001) Lancet , vol.357 , pp. 599-603
    • Nieman, K.1    Oudkerk, M.2    Rensing, B.J.3
  • 11
    • 0036373605 scopus 로고    scopus 로고
    • New technical developments in multislice CT, part 2: Sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging
    • Flohr, T., H. Bruder, K. Stierstorfer, et al. New technical developments in multislice CT, part 2: sub-millimeter 16-slice scanning and increased gantry rotation speed for cardiac imaging. Rofo 2002;174;1022-7
    • (2002) Rofo , vol.174 , pp. 1022-1027
    • Flohr, T.1    Bruder, H.2    Stierstorfer, K.3
  • 12
    • 0036325261 scopus 로고    scopus 로고
    • New technical developments in multislice CT-Part 1: Approaching isotropic resolution with submillimeter 16-slice scanning
    • Flohr, T., K. Stierstorfer, H. Bruder, et al. New technical developments in multislice CT-Part 1: Approaching isotropic resolution with submillimeter 16-slice scanning. Rofo 2002;174;839-45
    • (2002) Rofo , vol.174 , pp. 839-845
    • Flohr, T.1    Stierstorfer, K.2    Bruder, H.3
  • 13
    • 0036690311 scopus 로고    scopus 로고
    • CT angiography of pulmonary embolism in patients with underlying respiratory disease: Impact of multislice CT on image quality and negative predictive value
    • Remy-Jardin, M., I. Tillie-Leblond, D. Szapiro, et al. CT angiography of pulmonary embolism in patients with underlying respiratory disease: impact of multislice CT on image quality and negative predictive value. Eur Radiol 2002;12;1971-8
    • (2002) Eur Radiol , vol.12 , pp. 1971-1978
    • Remy-Jardin, M.1    Tillie-Leblond, I.2    Szapiro, D.3
  • 15
    • 0037109216 scopus 로고    scopus 로고
    • Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography
    • Nieman, K., F. Cademartiri, P. A. Lemos, et al. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography. Circulation 2002;106;2051-4
    • (2002) Circulation , vol.106 , pp. 2051-2054
    • Nieman, K.1    Cademartiri, F.2    Lemos, P.A.3
  • 16
    • 0037432175 scopus 로고    scopus 로고
    • Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction
    • Ropers, D., U. Baum, K. Pohle, et al. Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation 2003;107;664-6
    • (2003) Circulation , vol.107 , pp. 664-666
    • Ropers, D.1    Baum, U.2    Pohle, K.3
  • 17
    • 10344230948 scopus 로고    scopus 로고
    • Performance evaluation of a 64-slice CT system with z-flying focal spot
    • Flohr, T., K. Stierstorfer, R. Raupach, et al. Performance evaluation of a 64-slice CT system with z-flying focal spot. Rofo 2004;176;1803-10
    • (2004) Rofo , vol.176 , pp. 1803-1810
    • Flohr, T.1    Stierstorfer, K.2    Raupach, R.3
  • 18
    • 23944513257 scopus 로고    scopus 로고
    • Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot
    • Flohr, T. G., K. Stierstorfer, S. Ulzheimer, et al. Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot. Med Phys 2005;32;2536-47
    • (2005) Med Phys , vol.32 , pp. 2536-2547
    • Flohr, T.G.1    Stierstorfer, K.2    Ulzheimer, S.3
  • 20
    • 21344460533 scopus 로고    scopus 로고
    • Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: A comparative study with quantitative coronary angiography and intravascular ultrasound
    • Leber, A. W., A. Knez, F. Von Ziegler, et al. Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound. J Am Coll Cardiol 2005;46;147-54
    • (2005) J Am Coll Cardiol , vol.46 , pp. 147-154
    • Leber, A.W.1    Knez, A.2    Von Ziegler, F.3
  • 21
    • 22844448174 scopus 로고    scopus 로고
    • Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography
    • Raff, G. L., M. J. Gallagher, W. W. O'Neill, et al. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 2005;46;552-7
    • (2005) J Am Coll Cardiol , vol.46 , pp. 552-557
    • Raff, G.L.1    Gallagher, M.J.2    O'Neill, W.W.3
  • 22
    • 33750292412 scopus 로고    scopus 로고
    • Noninvasive coronary angiography with 64-section CT: Effect of average heart rate and heart rate variability on image quality
    • Leschka, S., S. Wildermuth, T. Boehm, et al. Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality. Radiology 2006;241;378-85
    • (2006) Radiology , vol.241 , pp. 378-385
    • Leschka, S.1    Wildermuth, S.2    Boehm, T.3
  • 23
    • 31444454089 scopus 로고    scopus 로고
    • First performance evaluation of a dual-source CT (DSCT) system
    • Flohr, T. G., C. H. McCollough, H. Bruder, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 2006;16;256-68
    • (2006) Eur Radiol , vol.16 , pp. 256-268
    • Flohr, T.G.1    McCollough, C.H.2    Bruder, H.3
  • 24
    • 32844464236 scopus 로고    scopus 로고
    • Contrast-enhanced coronary artery visualization by dual-source computed tomography-initial experience
    • Achenbach, S., D. Ropers, A. Kuettner, et al. Contrast-enhanced coronary artery visualization by dual-source computed tomography-initial experience. Eur J Radiol 2006;57;331-5
    • (2006) Eur J Radiol , vol.57 , pp. 331-335
    • Achenbach, S.1    Ropers, D.2    Kuettner, A.3
  • 26
    • 33947399137 scopus 로고    scopus 로고
    • Accuracy of dual-source CT coronary angiography: First experience in a high pre-test probability population without heart rate control
    • Scheffel, H., H. Alkadhi, A. Plass, et al. Accuracy of dual-source CT coronary angiography: First experience in a high pre-test probability population without heart rate control. Eur Radiol 2006;16;2739-47
    • (2006) Eur Radiol , vol.16 , pp. 2739-2747
    • Scheffel, H.1    Alkadhi, H.2    Plass, A.3
  • 27
    • 36348977491 scopus 로고    scopus 로고
    • Dual-source computed tomography in patients with acute chest pain: Feasibility and image quality
    • Schertler, T., H. Scheffel, T. Frauenfelder, et al. Dual-source computed tomography in patients with acute chest pain: feasibility and image quality. Eur Radiol 2007
    • (2007) Eur Radiol
    • Schertler, T.1    Scheffel, H.2    Frauenfelder, T.3
  • 28
    • 34249023378 scopus 로고    scopus 로고
    • Dose performance of a 64-channel dual-source CT scanner
    • McCollough, C. H., A. N. Primak, O. Saba, et al. Dose performance of a 64-channel dual-source CT scanner. Radiology 2007;243;775-84
    • (2007) Radiology , vol.243 , pp. 775-784
    • McCollough, C.H.1    Primak, A.N.2    Saba, O.3
  • 29
    • 0022528984 scopus 로고
    • Evaluation of a prototype dual-energy computed tomographic apparatus. II. Determinationof vertebral bone mineral content
    • Vetter JR, Perman WH, Kalender WA, Mazess RB, Holden JE. Evaluation of a prototype dual-energy computed tomographic apparatus. II. Determinationof vertebral bone mineral content. Medical Physics, 1986, 13:340-343
    • (1986) Medical Physics , vol.13 , pp. 340-343
    • Vetter, J.R.1    Perman, W.H.2    Kalender, W.A.3    Mazess, R.B.4    Holden, J.E.5
  • 30
    • 0022528983 scopus 로고
    • Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies
    • Kalender WA, Perman WH, Vetter JR, Klotz E. Evaluation of a prototype dual-energy computed tomographic apparatus. I. Phantom studies. Med. Phys., 1986, 13(3):334-339
    • (1986) Med. Phys. , vol.13 , Issue.3 , pp. 334-339
    • Kalender, W.A.1    Perman, W.H.2    Vetter, J.R.3    Klotz, E.4
  • 31
    • 34248673159 scopus 로고    scopus 로고
    • Material differentiation by dual energy CT: Initial experience
    • Johnson, T. R., B. Krauss, M. Sedlmair, et al. Material differentiation by dual energy CT: initial experience. Eur Radiol 2007;17;1510-7
    • (2007) Eur Radiol , vol.17 , pp. 1510-1517
    • Johnson, T.R.1    Krauss, B.2    Sedlmair, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.