메뉴 건너뛰기




Volumn 5242 LNCS, Issue PART 2, 2008, Pages 710-717

Real-time simulation of 4D lung tumor radiotherapy using a breathing model

Author keywords

[No Author keywords available]

Indexed keywords

BIOLOGICAL ORGANS; COMPUTERIZED TOMOGRAPHY; DEFORMATION; MEDICAL COMPUTING; MEDICAL IMAGING; RADIOTHERAPY;

EID: 58849165308     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-540-85990-1_85     Document Type: Conference Paper
Times cited : (16)

References (10)
  • 1
    • 0038710311 scopus 로고    scopus 로고
    • A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: A Monte Carlo study
    • Chetty, I.J., Rosu, M., Neelam, T., Marsh, L.H., McShan, D.L., Balter, J.M., Fraass, B.A., Ten Haken, R.K.: A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: a Monte Carlo study. Medical Physics 7, 1776-1780 (2003)
    • (2003) Medical Physics , vol.7 , pp. 1776-1780
    • Chetty, I.J.1    Rosu, M.2    Neelam, T.3    Marsh, L.H.4    McShan, D.L.5    Balter, J.M.6    Fraass, B.A.7    Ten Haken, R.K.8
  • 4
    • 10744222972 scopus 로고    scopus 로고
    • A method for the re-construction of four dimensional synchronized CT scans acquired during free breathing
    • Low, D.A.: A method for the re-construction of four dimensional synchronized CT scans acquired during free breathing. Medical Physics 30(6), 1254-1263 (2003)
    • (2003) Medical Physics , vol.30 , Issue.6 , pp. 1254-1263
    • Low, D.A.1
  • 6
    • 33748566269 scopus 로고    scopus 로고
    • Real-time respiration monitoring using the radiotherapy treatment beam and four dimensional computed tomography (4DCT)- a conceptual study
    • Lu, W.: Real-time respiration monitoring using the radiotherapy treatment beam and four dimensional computed tomography (4DCT)- a conceptual study. Physics in Medicine and Biology 51(18), 4469-4495 (2006)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.18 , pp. 4469-4495
    • Lu, W.1
  • 9
    • 41549167167 scopus 로고    scopus 로고
    • An inverse 3D lung deformation analysis for medical visualization
    • Geneva, Switzerland, pp, Computer Graphics Society
    • Santhanam, A.P., Mudur, S.P., Rolland, J.P.: An inverse 3D lung deformation analysis for medical visualization. In: Computer Animation and Social Agents, Geneva, Switzerland, pp. 229-242. Computer Graphics Society (2006)
    • (2006) Computer Animation and Social Agents , pp. 229-242
    • Santhanam, A.P.1    Mudur, S.P.2    Rolland, J.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.