-
1
-
-
0026603841
-
Myotonic dystrophy mutation: an unstable CTG repeat in the 3' untranslated region of the gene
-
Mahadevan M., Tsilfidis C., Sabourin L., et al. Myotonic dystrophy mutation: an unstable CTG repeat in the 3' untranslated region of the gene. Science 255 (1992) 1253-1255
-
(1992)
Science
, vol.255
, pp. 1253-1255
-
-
Mahadevan, M.1
Tsilfidis, C.2
Sabourin, L.3
-
2
-
-
0026598119
-
An unstable triplet repeat in a gene related to myotonic muscular dystrophy
-
Fu Y.H., Pizzuti A., Fenwick Jr. R.G., et al. An unstable triplet repeat in a gene related to myotonic muscular dystrophy. Science 255 (1992) 1256-1258
-
(1992)
Science
, vol.255
, pp. 1256-1258
-
-
Fu, Y.H.1
Pizzuti, A.2
Fenwick Jr., R.G.3
-
3
-
-
0026566108
-
Molecular basis of myotonic dystrophy: expansion of a trinucleotide (CTG) repeat at the 3' end of transcript encoding a protein kinase family member
-
Brook J.D., McCurrach M.E., Harley H.G., et al. Molecular basis of myotonic dystrophy: expansion of a trinucleotide (CTG) repeat at the 3' end of transcript encoding a protein kinase family member. Cell 68 (1992) 799-808
-
(1992)
Cell
, vol.68
, pp. 799-808
-
-
Brook, J.D.1
McCurrach, M.E.2
Harley, H.G.3
-
4
-
-
58849094674
-
Myotonic dystrophy
-
Rimoin D.L., Connor J.M., Pyeritz R.E., and Korf B.R. (Eds), Churchill Livingstone, Edinburgh vol. III; Chapter 129
-
Harper P.S. Myotonic dystrophy. In: Rimoin D.L., Connor J.M., Pyeritz R.E., and Korf B.R. (Eds). Emery and Rimoin's Principles and Practice of Medical Genetics. 4th ed. (2002), Churchill Livingstone, Edinburgh 3393-3418 vol. III; Chapter 129
-
(2002)
Emery and Rimoin's Principles and Practice of Medical Genetics. 4th ed.
, pp. 3393-3418
-
-
Harper, P.S.1
-
5
-
-
0020955194
-
Ocular hypotony in myotonic dystrophy
-
Dreyer R.F. Ocular hypotony in myotonic dystrophy. Int Ophthalmol 6 (1983) 221-223
-
(1983)
Int Ophthalmol
, vol.6
, pp. 221-223
-
-
Dreyer, R.F.1
-
6
-
-
58849121962
-
25 years dystrophia myotonica (D.M.)
-
Vos T.A. 25 years dystrophia myotonica (D.M.). Ophthalmologica 141 (1961) 37-45
-
(1961)
Ophthalmologica
, vol.141
, pp. 37-45
-
-
Vos, T.A.1
-
7
-
-
84960950060
-
Hypotension des Bulbus und Katarakt bei myotonischer Dystrophie [in German]
-
Kuhn E., and Piesbergen H.J. Hypotension des Bulbus und Katarakt bei myotonischer Dystrophie [in German]. Klin Monatsbl Augenheilkd Augenarztl Fortbild 130 (1957) 329-335
-
(1957)
Klin Monatsbl Augenheilkd Augenarztl Fortbild
, vol.130
, pp. 329-335
-
-
Kuhn, E.1
Piesbergen, H.J.2
-
9
-
-
0018084046
-
Ocular abnormality in myotonic dystrophy
-
Ginsberg J., Hamblet J., and Menefee M. Ocular abnormality in myotonic dystrophy. Ann Ophthalmol 10 (1978) 1021-1028
-
(1978)
Ann Ophthalmol
, vol.10
, pp. 1021-1028
-
-
Ginsberg, J.1
Hamblet, J.2
Menefee, M.3
-
11
-
-
0014231767
-
Histological findings in a case of dystrophia myotonica
-
Manschot W.A. Histological findings in a case of dystrophia myotonica. Ophthalmologica 155 (1968) 294-296
-
(1968)
Ophthalmologica
, vol.155
, pp. 294-296
-
-
Manschot, W.A.1
-
12
-
-
0014575313
-
Ocular histopathology of myotonic dystrophy: a clinicopathologic case report
-
Burns C.A. Ocular histopathology of myotonic dystrophy: a clinicopathologic case report. Am J Ophthalmol 68 (1969) 416-422
-
(1969)
Am J Ophthalmol
, vol.68
, pp. 416-422
-
-
Burns, C.A.1
-
13
-
-
0014906919
-
Uveo-retinal lesions in myotonic dystrophy: histological study [in French]
-
Houber J.P., and Babel J. Uveo-retinal lesions in myotonic dystrophy: histological study [in French]. Ann Ocul (Paris) 203 (1970) 1067-1076
-
(1970)
Ann Ocul (Paris)
, vol.203
, pp. 1067-1076
-
-
Houber, J.P.1
Babel, J.2
-
14
-
-
0027291601
-
Sources of error with use of Goldmann-type tonometers
-
Whitacre M.M., and Stein R. Sources of error with use of Goldmann-type tonometers. Surv Ophthalmol 38 (1993) 1-30
-
(1993)
Surv Ophthalmol
, vol.38
, pp. 1-30
-
-
Whitacre, M.M.1
Stein, R.2
-
15
-
-
37349045954
-
Influence of corneal structure, corneal responsiveness, and other ocular parameters on tonometric measurement of intraocular pressure
-
Broman A.T., Congdon N.G., Bandeen-Roche K., and Quigley H.A. Influence of corneal structure, corneal responsiveness, and other ocular parameters on tonometric measurement of intraocular pressure. J Glaucoma 16 (2007) 581-588
-
(2007)
J Glaucoma
, vol.16
, pp. 581-588
-
-
Broman, A.T.1
Congdon, N.G.2
Bandeen-Roche, K.3
Quigley, H.A.4
-
16
-
-
0034603359
-
Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach
-
Doughty M.J., and Zaman M.L. Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. Surv Ophthalmol 44 (2000) 367-408
-
(2000)
Surv Ophthalmol
, vol.44
, pp. 367-408
-
-
Doughty, M.J.1
Zaman, M.L.2
-
17
-
-
33747346135
-
Effects of central corneal thickness and corneal curvature on the intraocular pressure measurement by Goldmann applanation tonometer and ocular blood flow pneumatonometer
-
Saleh T.A., Adams M., McDermott B., et al. Effects of central corneal thickness and corneal curvature on the intraocular pressure measurement by Goldmann applanation tonometer and ocular blood flow pneumatonometer. Clin Experiment Ophthalmol 34 (2006) 516-520
-
(2006)
Clin Experiment Ophthalmol
, vol.34
, pp. 516-520
-
-
Saleh, T.A.1
Adams, M.2
McDermott, B.3
-
18
-
-
33748924156
-
Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the Ocular Response Analyzer
-
Medeiros F.A., and Weinreb R.N. Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the Ocular Response Analyzer. J Glaucoma 15 (2006) 364-370
-
(2006)
J Glaucoma
, vol.15
, pp. 364-370
-
-
Medeiros, F.A.1
Weinreb, R.N.2
-
19
-
-
21344460937
-
The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry
-
Tonnu P.A., Ho T., Newson T., et al. The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry. Br J Ophthalmol 89 (2005) 851-854
-
(2005)
Br J Ophthalmol
, vol.89
, pp. 851-854
-
-
Tonnu, P.A.1
Ho, T.2
Newson, T.3
-
20
-
-
33750591541
-
Ocular Response Analyzer versus Goldmann applanation tonometry for intraocular pressure measurements
-
Martinez-de-la-Casa J.M., Garcia-Feijoo J., Fernandez-Vidal A., et al. Ocular Response Analyzer versus Goldmann applanation tonometry for intraocular pressure measurements. Invest Ophthalmol Vis Sci 47 (2006) 4410-4414
-
(2006)
Invest Ophthalmol Vis Sci
, vol.47
, pp. 4410-4414
-
-
Martinez-de-la-Casa, J.M.1
Garcia-Feijoo, J.2
Fernandez-Vidal, A.3
-
21
-
-
33845807890
-
Effects of corneal thickness, corneal curvature, and intraocular pressure level on Goldmann applanation tonometry and dynamic contour tonometry
-
Francis B.A., Hsieh A., Lai M.Y., et al. Effects of corneal thickness, corneal curvature, and intraocular pressure level on Goldmann applanation tonometry and dynamic contour tonometry. Ophthalmology 114 (2007) 20-26
-
(2007)
Ophthalmology
, vol.114
, pp. 20-26
-
-
Francis, B.A.1
Hsieh, A.2
Lai, M.Y.3
-
22
-
-
34547349120
-
The influence of corneal hysteresis and corneal resistance factor on the measurement of intraocular pressure [in German]
-
Hager A., Schroeder B., Sadeghi M., et al. The influence of corneal hysteresis and corneal resistance factor on the measurement of intraocular pressure [in German]. Ophthalmologe 104 (2007) 484-489
-
(2007)
Ophthalmologe
, vol.104
, pp. 484-489
-
-
Hager, A.1
Schroeder, B.2
Sadeghi, M.3
-
23
-
-
33645846918
-
Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry
-
Kohlhaas M., Boehm A.G., Spoerl E., et al. Effect of central corneal thickness, corneal curvature, and axial length on applanation tonometry. Arch Ophthalmol 124 (2006) 471-476
-
(2006)
Arch Ophthalmol
, vol.124
, pp. 471-476
-
-
Kohlhaas, M.1
Boehm, A.G.2
Spoerl, E.3
-
24
-
-
13844317411
-
Determining in vivo biomechanical properties of the cornea with an Ocular Response Analyzer
-
Luce D.A. Determining in vivo biomechanical properties of the cornea with an Ocular Response Analyzer. J Cataract Refract Surg 31 (2005) 156-162
-
(2005)
J Cataract Refract Surg
, vol.31
, pp. 156-162
-
-
Luce, D.A.1
-
25
-
-
41249092492
-
Correlations between corneal hysteresis, intraocular pressure, and corneal central pachymetry
-
Touboul D., Roberts C., Kérautret J., et al. Correlations between corneal hysteresis, intraocular pressure, and corneal central pachymetry. J Cataract Refract Surg 34 (2008) 616-622
-
(2008)
J Cataract Refract Surg
, vol.34
, pp. 616-622
-
-
Touboul, D.1
Roberts, C.2
Kérautret, J.3
|