메뉴 건너뛰기




Volumn 38, Issue 3, 2009, Pages 225-236

Accuracy of whole-body low-dose multidetector CT (WBLDCT) versus skeletal survey in the detection of myelomatous lesions, and correlation of disease distribution with whole-body MRI (WBMRI)

Author keywords

Computed tomography; MRI; Multiple myeloma; Radiation dosage; Radiographs; Whole body imaging

Indexed keywords

ADULT; AGED; ARTICLE; BONE ATROPHY; BONE MARROW BIOPSY; CANCER STAGING; CLINICAL ARTICLE; CLINICAL PROTOCOL; CLINICAL TRIAL; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CORTICAL BONE; DIAGNOSTIC ACCURACY; EVALUATION; FEMALE; GOLD STANDARD; HUMAN; IMAGE QUALITY; LOW ENERGY RADIATION; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; MULTIPLE MYELOMA; OSTEOLYSIS; PATIENT REFERRAL; PLASMA CELL DYSCRASIA; PRIORITY JOURNAL; RADIATION DOSE; RADIOLOGIST; RANDOMIZED CONTROLLED TRIAL; SIGNAL DETECTION; WHOLE BODY IMAGING; WHOLE BODY MRI;

EID: 58849133680     PISSN: 03642348     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00256-008-0607-4     Document Type: Article
Times cited : (136)

References (28)
  • 1
    • 0037105403 scopus 로고    scopus 로고
    • Magnetic resonance imaging as a supplement for the clinical staging system of Durie and Salmon?
    • A Baur A Stabler D Nagel 2002 Magnetic resonance imaging as a supplement for the clinical staging system of Durie and Salmon? Cancer 95 1334 1345
    • (2002) Cancer , vol.95 , pp. 1334-1345
    • Baur, A.1    Stabler, A.2    Nagel, D.3
  • 2
    • 33746515610 scopus 로고    scopus 로고
    • The role of anatomic and functional staging in myeloma: Description of Durie/Salmon plus staging system
    • BGM Durie 2006 The role of anatomic and functional staging in myeloma: description of Durie/Salmon plus staging system Eur J Cancer 42 1539 1543
    • (2006) Eur J Cancer , vol.42 , pp. 1539-1543
    • Durie, B.G.M.1
  • 3
    • 0036107643 scopus 로고    scopus 로고
    • Multidetector CT of the spine in multiple myeloma: Comparison with MR imaging and radiography
    • AH Mahnken JE Wildberger G Gehbauer 2002 Multidetector CT of the spine in multiple myeloma: comparison with MR imaging and radiography AJR 178 1429 1426
    • (2002) AJR , vol.178 , pp. 1429-1426
    • Mahnken, A.H.1    Wildberger, J.E.2    Gehbauer, G.3
  • 4
    • 35148825003 scopus 로고    scopus 로고
    • Extended follow-up of a phase 3 trial in relapsed multiple myeloma: Final time-to-event results of the APEX trial
    • PG Richardson P Sonneveld M Schuster 2007 Extended follow-up of a phase 3 trial in relapsed multiple myeloma: final time-to-event results of the APEX trial Blood 110 3557 3560
    • (2007) Blood , vol.110 , pp. 3557-3560
    • Richardson, P.G.1    Sonneveld, P.2    Schuster, M.3
  • 5
    • 0036226029 scopus 로고    scopus 로고
    • Fluoro-deoxyglucose positron emission tomography imaging for the detection of occult disease in multiple myeloma
    • K Orchard S Barrington J Buscombe A Hilson HG Prentice A Metha 2002 Fluoro-deoxyglucose positron emission tomography imaging for the detection of occult disease in multiple myeloma Br J Haematol 117 133 135
    • (2002) Br J Haematol , vol.117 , pp. 133-135
    • Orchard, K.1    Barrington, S.2    Buscombe, J.3    Hilson, A.4    Prentice, H.G.5    Metha, A.6
  • 6
    • 18244369257 scopus 로고    scopus 로고
    • Value of FDG PET in the assessment of patients with multiple myeloma
    • MA Bredella L Steinbach G Caputo G Segall R Hawkins 2005 Value of FDG PET in the assessment of patients with multiple myeloma AJR 184 1199 1204
    • (2005) AJR , vol.184 , pp. 1199-1204
    • Bredella, M.A.1    Steinbach, L.2    Caputo, G.3    Segall, G.4    Hawkins, R.5
  • 8
    • 0346876278 scopus 로고    scopus 로고
    • Whole-body dual-modality PET/CT and whole-body MRI for tumour staging in oncology
    • G Antoch FM Vogt LS Freudenberg 2003 Whole-body dual-modality PET/CT and whole-body MRI for tumour staging in oncology JAMA 290 3199 3206
    • (2003) JAMA , vol.290 , pp. 3199-3206
    • Antoch, G.1    Vogt, F.M.2    Freudenberg, L.S.3
  • 9
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography-an increasing source of radiation exposure
    • DJ Brenner EJ Hall D Phil 2007 Computed tomography-an increasing source of radiation exposure N Engl J Med 357 2277 2284
    • (2007) N Engl J Med , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2    Phil, D.3
  • 10
    • 34249696084 scopus 로고    scopus 로고
    • The 15-country collaborative study of cancer risk in radiation workers in the nuclear industry: Estimates of radiation-related cancer risks
    • E Cardis M Vrijheid M Blettner 2007 The 15-country collaborative study of cancer risk in radiation workers in the nuclear industry: estimates of radiation-related cancer risks Radiation Research 167 396 416
    • (2007) Radiation Research , vol.167 , pp. 396-416
    • Cardis, E.1    Vrijheid, M.2    Blettner, M.3
  • 11
    • 17144395881 scopus 로고    scopus 로고
    • Whole-body low-dose multidetector row-CT in the diagnosis of multiple myeloma: An alternative to conventional radiography
    • M Horger CD Claussen U Bross-Bach 2005 Whole-body low-dose multidetector row-CT in the diagnosis of multiple myeloma: an alternative to conventional radiography Eur J Rad 54 289 297
    • (2005) Eur J Rad , vol.54 , pp. 289-297
    • Horger, M.1    Claussen, C.D.2    Bross-Bach, U.3
  • 12
    • 58849135909 scopus 로고    scopus 로고
    • Dose optimization in whole body low dose multidetector CT (MDCT) in the staging of multiple myeloma. scholars and awards session: Residents in radiology awards
    • Orlando, 8th May
    • Gleeson TG, Byrne B, Kenny P, Fitzpatrick P, O'Gorman P, Eustace SJ. Dose Optimization in Whole Body Low Dose Multidetector CT (MDCT) in the Staging of Multiple Myeloma. Scholars and Awards Session: Residents in Radiology Awards. ARRS Annual Meeting, Orlando, 8th May, 2007.
    • (2007) ARRS Annual Meeting
    • Gleeson, T.G.1    Byrne, B.2    Kenny, P.3    Fitzpatrick, P.4    O'Gorman, P.5    Eustace, S.J.6
  • 14
    • 42449157054 scopus 로고    scopus 로고
    • Whole-body MRI versus whole-body MDCT for staging of multiple myeloma
    • A Baur-Melnyk S Buhmann C Becker 2008 Whole-body MRI versus whole-body MDCT for staging of multiple myeloma AJR 190 1097 1104
    • (2008) AJR , vol.190 , pp. 1097-1104
    • Baur-Melnyk, A.1    Buhmann, S.2    Becker, C.3
  • 15
    • 36148996859 scopus 로고    scopus 로고
    • Whole-body imaging of the musculoskeletal system: The value of MR imaging
    • GP Schmidt MF Reiser AB Baur-Melnyk 2007 Whole-body imaging of the musculoskeletal system: the value of MR imaging Skeletal Radiol 36 1109 1119
    • (2007) Skeletal Radiol , vol.36 , pp. 1109-1119
    • Schmidt, G.P.1    Reiser, M.F.2    Baur-Melnyk, A.B.3
  • 16
    • 34047195753 scopus 로고    scopus 로고
    • Magnetic resonance imaging in multiple myeloma: Diagnostic and clinical implications
    • R Walker B Barlogie J Haessler 2007 Magnetic resonance imaging in multiple myeloma: diagnostic and clinical implications J Clin Oncol 25 1121 1128
    • (2007) J Clin Oncol , vol.25 , pp. 1121-1128
    • Walker, R.1    Barlogie, B.2    Haessler, J.3
  • 17
    • 0022973287 scopus 로고
    • Staging and kinetics of multiple myeloma
    • BGM Durie 1986 Staging and kinetics of multiple myeloma Sem Oncol 13 300 309
    • (1986) Sem Oncol , vol.13 , pp. 300-309
    • Durie, B.G.M.1
  • 18
    • 38949212963 scopus 로고    scopus 로고
    • Comparison of whole-body 64-slice multidetector computed tomography and conventional radiography in staging of multiple myeloma
    • P Kropil R Fenk LB Fritz 2008 Comparison of whole-body 64-slice multidetector computed tomography and conventional radiography in staging of multiple myeloma Eur Radiol 18 51 58
    • (2008) Eur Radiol , vol.18 , pp. 51-58
    • Kropil, P.1    Fenk, R.2    Fritz, L.B.3
  • 19
    • 33846471867 scopus 로고    scopus 로고
    • Patient radiation doses from adult and pediatric CT
    • W Huda A Vance 2007 Patient radiation doses from adult and pediatric CT AJR 188 540 546
    • (2007) AJR , vol.188 , pp. 540-546
    • Huda, W.1    Vance, A.2
  • 20
    • 0032817636 scopus 로고    scopus 로고
    • Skeletal survey in advanced multiple myeloma: Radiographic versus MR imaging survey
    • FE Lecouvet J Malghem L Michaux 2000 Skeletal survey in advanced multiple myeloma: radiographic versus MR imaging survey Br J Haematol 106 35 39
    • (2000) Br J Haematol , vol.106 , pp. 35-39
    • Lecouvet, F.E.1    Malghem, J.2    Michaux, L.3
  • 21
    • 59649121378 scopus 로고    scopus 로고
    • Whole-body MRI of multiple myeloma: Comparison of different MRI sequences in assessment of different growth patterns
    • December 18 (e-publication ahead of print)
    • Weininger M, Lauterbach B, Knop S, et al. Whole-body MRI of multiple myeloma: Comparison of different MRI sequences in assessment of different growth patterns. Eur J Radiol 2007, December 18 (e-publication ahead of print).
    • Eur J Radiol 2007
    • Weininger, M.1    Lauterbach, B.2    Knop, S.3
  • 22
    • 33645775012 scopus 로고    scopus 로고
    • Whole-body MRI in the detection of bone marrow infiltration in patients with plasma cell neoplasms in comparison to the radiological skeletal survey
    • N Ghanem C Lohrmann M Engelhardt 2006 Whole-body MRI in the detection of bone marrow infiltration in patients with plasma cell neoplasms in comparison to the radiological skeletal survey Eur Radiol 16 1005 1014
    • (2006) Eur Radiol , vol.16 , pp. 1005-1014
    • Ghanem, N.1    Lohrmann, C.2    Engelhardt, M.3
  • 23
    • 20444376144 scopus 로고    scopus 로고
    • Role of MRI for the diagnosis and prognosis of multiple myeloma
    • A Baur-Melnyk S Buhmann HR Durr M Reiser 2005 Role of MRI for the diagnosis and prognosis of multiple myeloma Eur J Rad 55 56 63
    • (2005) Eur J Rad , vol.55 , pp. 56-63
    • Baur-Melnyk, A.1    Buhmann, S.2    Durr, H.R.3    Reiser, M.4
  • 24
    • 34247108028 scopus 로고    scopus 로고
    • The benefit of using whole-body, low-dose, nonenhanced, multidetector computed tomography for follow-up and therapy response monitoring in patients with multiple myeloma
    • M Horger L Kna B Denecke 2007 The benefit of using whole-body, low-dose, nonenhanced, multidetector computed tomography for follow-up and therapy response monitoring in patients with multiple myeloma Cancer 109 1616 1626
    • (2007) Cancer , vol.109 , pp. 1616-1626
    • Horger, M.1    Kna, L.2    Denecke, B.3
  • 25
    • 34250762705 scopus 로고    scopus 로고
    • Can low-dose computed tomographic scan of the spine replace conventional radiography? An evaluation based on imaging myelomas, bone metastases, and fractures from osteoporosis
    • M Chassang A Grimaud JM Cucchi 2007 Can low-dose computed tomographic scan of the spine replace conventional radiography? An evaluation based on imaging myelomas, bone metastases, and fractures from osteoporosis Clinical Imaging 31 225 227
    • (2007) Clinical Imaging , vol.31 , pp. 225-227
    • Chassang, M.1    Grimaud, A.2    Cucchi, J.M.3
  • 26
    • 0036363637 scopus 로고    scopus 로고
    • Radiation dose in CT: Are we meeting the challenge? (commentary)
    • SJ Golding PC Shrimpton 2002 Radiation dose in CT: are we meeting the challenge? (commentary) Br J Radiol 75 1 4
    • (2002) Br J Radiol , vol.75 , pp. 1-4
    • Golding, S.J.1    Shrimpton, P.C.2
  • 27
    • 27744501051 scopus 로고    scopus 로고
    • Patient dose reduction in CT (Commentary)
    • MA Lewis 2005 Patient dose reduction in CT (Commentary) Br J Radiol 78 880 883
    • (2005) Br J Radiol , vol.78 , pp. 880-883
    • Lewis, M.A.1
  • 28
    • 0038037974 scopus 로고    scopus 로고
    • Radiation exposure at chest CT: A statement of the Fleischner Society
    • JR Mayo J Aldrich NL Muller 2003 Radiation exposure at chest CT: a statement of the Fleischner Society Radiology 228 15 21
    • (2003) Radiology , vol.228 , pp. 15-21
    • Mayo, J.R.1    Aldrich, J.2    Muller, N.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.