메뉴 건너뛰기




Volumn 3036, Issue , 1997, Pages 39-47

Observer detection performance loss: Target size uncertainty

Author keywords

Image perception; ROC; Target size

Indexed keywords

COMPUTER WORKSTATIONS; COMPUTERIZED TOMOGRAPHY; CURVE FITTING; MATCHED FILTERS; MEDICAL IMAGING; PATTERN MATCHING; PIXELS; RENDERING (COMPUTER GRAPHICS); SIGNAL PROCESSING;

EID: 58849116911     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.271310     Document Type: Conference Paper
Times cited : (9)

References (21)
  • 1
    • 58849125666 scopus 로고    scopus 로고
    • Detail is intended denote a target of contiguous image data that human visual system may recognize as an object. In a medical image, this perceived object may be associated with a real object such as a tumor. This presentation is concerned with the detection of details, because detail does not seem to be used to make this distinction this presentation will use the more general term, target, instead. Some results and observations in this may not generalize to the detection of targets that are not compact.
    • Detail is intended denote a target of contiguous image data that human visual system may recognize as an object. In a medical image, this perceived object may be associated with a real object such as a tumor. This presentation is concerned with the detection of details, because "detail" does not seem to be used to make this distinction this presentation will use the more general term, target, instead. Some results and observations in this may not generalize to the detection of targets that are not compact.
  • 3
    • 0021973433 scopus 로고
    • Detectability of lesions of various sizes on CT images
    • Application of Optical Instrumentation in Medicine XIII, Medical Image Production, Processing and Display, pp
    • P. F. Judy and R. G. Swensson. "Detectability of lesions of various sizes on CT images", SPIE Vol. 535 - Application of Optical Instrumentation in Medicine XIII, Medical Image Production, Processing and Display, pp 38-42, 1985.
    • (1985) SPIE , vol.535 , pp. 38-42
    • Judy, P.F.1    Swensson, R.G.2
  • 5
    • 0028151488 scopus 로고
    • Flattening of the contrast-detail curve for large lesion on liver CT images
    • S. E. Seltzer, P. F. Judy, R. G. Swensson, K. H. Chan, R. D. Nawfel , "Flattening of the contrast-detail curve for large lesion on liver CT images," Med. Phys. 20:1547-546, 1994.
    • (1994) Med. Phys , vol.20 , pp. 1547-2546
    • Seltzer, S.E.1    Judy, P.F.2    Swensson, R.G.3    Chan, K.H.4    Nawfel, R.D.5
  • 6
    • 0001951712 scopus 로고
    • Decision theory and the detail SNR of Otto Schade
    • R. F. Wagner , "Decision theory and the detail SNR of Otto Schade," Photog Sci Eng 22:41-46, 1978.
    • (1978) Photog Sci Eng , vol.22 , pp. 41-46
    • Wagner, R.F.1
  • 8
    • 0021848431 scopus 로고
    • Unified SNR analysis of medical imaging systems
    • R. F. Wagner, D. G. Brown, "Unified SNR analysis of medical imaging systems," Phys Med Biol 30:498-518, 1985.
    • (1985) Phys Med Biol , vol.30 , pp. 498-518
    • Wagner, R.F.1    Brown, D.G.2
  • 9
    • 0021968255 scopus 로고
    • Detection of small focal lesions in CT images: Effects of reconstruction filters and visual display windows
    • P.F. Judy and R. G. Swensson, "Detection of small focal lesions in CT images: effects of reconstruction filters and visual display windows," Br J Radiol 58:137-145, 1985.
    • (1985) Br J Radiol , vol.58 , pp. 137-145
    • Judy, P.F.1    Swensson, R.G.2
  • 11
    • 0026635787 scopus 로고
    • Evaluation of video gray-scale display
    • R. D. Nawfel et al. "Evaluation of video gray-scale display", Med. Phys. 19:3, 1992.
    • (1992) Med. Phys , vol.19 , pp. 3
    • Nawfel, R.D.1
  • 12
    • 0018733995 scopus 로고    scopus 로고
    • The area of the disk can not be calculated from its specified diameter because its profile is discretely sampled and was blurred slightly to avoid aliasing. The following formula was used to calculate the effective area of the disk and Gaussian targets. Ae ≡ (Σwi) 2/Σwi2, where wi is signal increment by the target at the ith pixel. Ae is an effective number pixels of the target. K. M. Hanson, Detectability in computed tomographic images, Med. Phys. 6;441-451, 1979
    • e is an effective number pixels of the target. K. M. Hanson, "Detectability in computed tomographic images," Med. Phys. 6;441-451, 1979.
  • 13
    • 0019952465 scopus 로고
    • A physical theory for detectability of targets in noisy images. I. Mathematical background, empirical review, and development of theory
    • P. R. Moran, "A physical theory for detectability of targets in noisy images. I. Mathematical background, empirical review, and development of theory," Med. Phys. 9;401-413, 1982.
    • (1982) Med. Phys , vol.9 , pp. 401-413
    • Moran, P.R.1
  • 14
    • 0347009200 scopus 로고
    • Observer Efficiency and Feature Polarity
    • Medical Imaging, pp
    • P. F. Judy, R. G. Swensson, M. F. Kijewski , "Observer Efficiency and Feature Polarity", SPIE Vol. 767 Medical Imaging, pp 310-316, 1987.
    • (1987) SPIE , vol.767 , pp. 310-316
    • Judy, P.F.1    Swensson, R.G.2    Kijewski, M.F.3
  • 16
    • 38649132833 scopus 로고
    • Maximum-likelihood estimation of parameters of signal-detection theory and determination of confidence intervals - Rating method data
    • D. D. Dorfman, E. Alf , "Maximum-likelihood estimation of parameters of signal-detection theory and determination of confidence intervals - Rating method data," J Math Psych 6:487-496, 1969.
    • (1969) J Math Psych , vol.6 , pp. 487-496
    • Dorfman, D.D.1    Alf, E.2
  • 18
    • 0023332788 scopus 로고
    • Display thresholding of images and observer detection performance
    • P. F. Judy and R. G. Swensson, "Display thresholding of images and observer detection performance," J Opt Soc Am (A) 4:954-965, 1987.
    • (1987) J Opt Soc Am (A) , vol.4 , pp. 954-965
    • Judy, P.F.1    Swensson, R.G.2
  • 19
    • 0029452629 scopus 로고
    • Observer Detection Efficiency with Targe Size Uncertainty
    • Medical Imaging, pp
    • P.F. Judy, M.F. Kijewski, X. Fu., R.G. Swensson, "Observer Detection Efficiency with Targe Size Uncertainty," SPIE Vol. 2436 Medical Imaging, pp 10-17, 1995.
    • (1995) SPIE , vol.2436 , pp. 10-17
    • Judy, P.F.1    Kijewski, M.F.2    Fu, X.3    Swensson, R.G.4
  • 20
    • 0019578259 scopus 로고
    • Detection of noisy visual targets: Models for the effect of spatial uncertainty and signal-to-noise ratio
    • R. G. Swensson, P. F. Judy, "Detection of noisy visual targets: models for the effect of spatial uncertainty and signal-to-noise ratio," Percep and Psychophys. 29:521-534, 1981.
    • (1981) Percep and Psychophys , vol.29 , pp. 521-534
    • Swensson, R.G.1    Judy, P.F.2
  • 21
    • 0022120676 scopus 로고
    • Uncertainty explains many aspects of visual contrast and detection discrimination
    • D. G. Pelli, "Uncertainty explains many aspects of visual contrast and detection discrimination," J. Opt. Soc. Am. A , 1508-1532, 1985.
    • (1985) J. Opt. Soc. Am. A , pp. 1508-1532
    • Pelli, D.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.