1
-
-
58849125666
-
-
Detail is intended denote a target of contiguous image data that human visual system may recognize as an object. In a medical image, this perceived object may be associated with a real object such as a tumor. This presentation is concerned with the detection of details, because detail does not seem to be used to make this distinction this presentation will use the more general term, target, instead. Some results and observations in this may not generalize to the detection of targets that are not compact.
-
Detail is intended denote a target of contiguous image data that human visual system may recognize as an object. In a medical image, this perceived object may be associated with a real object such as a tumor. This presentation is concerned with the detection of details, because "detail" does not seem to be used to make this distinction this presentation will use the more general term, target, instead. Some results and observations in this may not generalize to the detection of targets that are not compact.
-
-
-
-
3
-
-
0021973433
-
Detectability of lesions of various sizes on CT images
-
Application of Optical Instrumentation in Medicine XIII, Medical Image Production, Processing and Display, pp
-
P. F. Judy and R. G. Swensson. "Detectability of lesions of various sizes on CT images", SPIE Vol. 535 - Application of Optical Instrumentation in Medicine XIII, Medical Image Production, Processing and Display, pp 38-42, 1985.
-
(1985)
SPIE
, vol.535
, pp. 38-42
-
-
Judy, P.F.1
Swensson, R.G.2
-
4
-
-
0026806519
-
Contrast detail curves for liver CT
-
P. F. Judy, R. G. Swensson, R. D. Nawfel, K. H. Chan, S. E. Seltzer. "Contrast detail curves for liver CT," Med. Phys. 19:1167-1174, 1993.
-
(1993)
Med. Phys
, vol.19
, pp. 1167-1174
-
-
Judy, P.F.1
Swensson, R.G.2
Nawfel, R.D.3
Chan, K.H.4
Seltzer, S.E.5
-
5
-
-
0028151488
-
Flattening of the contrast-detail curve for large lesion on liver CT images
-
S. E. Seltzer, P. F. Judy, R. G. Swensson, K. H. Chan, R. D. Nawfel , "Flattening of the contrast-detail curve for large lesion on liver CT images," Med. Phys. 20:1547-546, 1994.
-
(1994)
Med. Phys
, vol.20
, pp. 1547-2546
-
-
Seltzer, S.E.1
Judy, P.F.2
Swensson, R.G.3
Chan, K.H.4
Nawfel, R.D.5
-
6
-
-
0001951712
-
Decision theory and the detail SNR of Otto Schade
-
R. F. Wagner , "Decision theory and the detail SNR of Otto Schade," Photog Sci Eng 22:41-46, 1978.
-
(1978)
Photog Sci Eng
, vol.22
, pp. 41-46
-
-
Wagner, R.F.1
-
7
-
-
0019870643
-
Efficiency of human visual signal discrimination
-
A. E. Burgess, R. F. Wagner, R. J. Jennings, H. B. Barlow, "Efficiency of human visual signal discrimination," Science 214:93-94, 1981.
-
(1981)
Science
, vol.214
, pp. 93-94
-
-
Burgess, A.E.1
Wagner, R.F.2
Jennings, R.J.3
Barlow, H.B.4
-
8
-
-
0021848431
-
Unified SNR analysis of medical imaging systems
-
R. F. Wagner, D. G. Brown, "Unified SNR analysis of medical imaging systems," Phys Med Biol 30:498-518, 1985.
-
(1985)
Phys Med Biol
, vol.30
, pp. 498-518
-
-
Wagner, R.F.1
Brown, D.G.2
-
9
-
-
0021968255
-
Detection of small focal lesions in CT images: Effects of reconstruction filters and visual display windows
-
P.F. Judy and R. G. Swensson, "Detection of small focal lesions in CT images: effects of reconstruction filters and visual display windows," Br J Radiol 58:137-145, 1985.
-
(1985)
Br J Radiol
, vol.58
, pp. 137-145
-
-
Judy, P.F.1
Swensson, R.G.2
-
10
-
-
0022135615
-
Effect of noise correlation on detectability of disk signals in medical imaging
-
K. J. Myers, H. H. Barrett, M. C. Borgstrom, D. D. Patton , G. W. Seely. "Effect of noise correlation on detectability of disk signals in medical imaging" J. Opt. Soc. Am. A, 1752-1759, 1985.
-
(1985)
J. Opt. Soc. Am. A
, pp. 1752-1759
-
-
Myers, K.J.1
Barrett, H.H.2
Borgstrom, M.C.3
Patton, D.D.4
Seely, G.W.5
-
11
-
-
0026635787
-
Evaluation of video gray-scale display
-
R. D. Nawfel et al. "Evaluation of video gray-scale display", Med. Phys. 19:3, 1992.
-
(1992)
Med. Phys
, vol.19
, pp. 3
-
-
Nawfel, R.D.1
-
12
-
-
0018733995
-
-
The area of the disk can not be calculated from its specified diameter because its profile is discretely sampled and was blurred slightly to avoid aliasing. The following formula was used to calculate the effective area of the disk and Gaussian targets. Ae ≡ (Σwi) 2/Σwi2, where wi is signal increment by the target at the ith pixel. Ae is an effective number pixels of the target. K. M. Hanson, Detectability in computed tomographic images, Med. Phys. 6;441-451, 1979
-
e is an effective number pixels of the target. K. M. Hanson, "Detectability in computed tomographic images," Med. Phys. 6;441-451, 1979.
-
-
-
-
13
-
-
0019952465
-
A physical theory for detectability of targets in noisy images. I. Mathematical background, empirical review, and development of theory
-
P. R. Moran, "A physical theory for detectability of targets in noisy images. I. Mathematical background, empirical review, and development of theory," Med. Phys. 9;401-413, 1982.
-
(1982)
Med. Phys
, vol.9
, pp. 401-413
-
-
Moran, P.R.1
-
14
-
-
0347009200
-
Observer Efficiency and Feature Polarity
-
Medical Imaging, pp
-
P. F. Judy, R. G. Swensson, M. F. Kijewski , "Observer Efficiency and Feature Polarity", SPIE Vol. 767 Medical Imaging, pp 310-316, 1987.
-
(1987)
SPIE
, vol.767
, pp. 310-316
-
-
Judy, P.F.1
Swensson, R.G.2
Kijewski, M.F.3
-
15
-
-
0001338991
-
Analysis of Rating Data from Multiple-Alternative Tasks
-
M. F. Kijewski , R. G. Swensson, P. F. Judy, "Analysis of Rating Data from Multiple-Alternative Tasks," Journal of Mathematical Psychology 33:428-451, 1989.
-
(1989)
Journal of Mathematical Psychology
, vol.33
, pp. 428-451
-
-
Kijewski, M.F.1
Swensson, R.G.2
Judy, P.F.3
-
16
-
-
38649132833
-
Maximum-likelihood estimation of parameters of signal-detection theory and determination of confidence intervals - Rating method data
-
D. D. Dorfman, E. Alf , "Maximum-likelihood estimation of parameters of signal-detection theory and determination of confidence intervals - Rating method data," J Math Psych 6:487-496, 1969.
-
(1969)
J Math Psych
, vol.6
, pp. 487-496
-
-
Dorfman, D.D.1
Alf, E.2
-
18
-
-
0023332788
-
Display thresholding of images and observer detection performance
-
P. F. Judy and R. G. Swensson, "Display thresholding of images and observer detection performance," J Opt Soc Am (A) 4:954-965, 1987.
-
(1987)
J Opt Soc Am (A)
, vol.4
, pp. 954-965
-
-
Judy, P.F.1
Swensson, R.G.2
-
19
-
-
0029452629
-
Observer Detection Efficiency with Targe Size Uncertainty
-
Medical Imaging, pp
-
P.F. Judy, M.F. Kijewski, X. Fu., R.G. Swensson, "Observer Detection Efficiency with Targe Size Uncertainty," SPIE Vol. 2436 Medical Imaging, pp 10-17, 1995.
-
(1995)
SPIE
, vol.2436
, pp. 10-17
-
-
Judy, P.F.1
Kijewski, M.F.2
Fu, X.3
Swensson, R.G.4
-
20
-
-
0019578259
-
Detection of noisy visual targets: Models for the effect of spatial uncertainty and signal-to-noise ratio
-
R. G. Swensson, P. F. Judy, "Detection of noisy visual targets: models for the effect of spatial uncertainty and signal-to-noise ratio," Percep and Psychophys. 29:521-534, 1981.
-
(1981)
Percep and Psychophys
, vol.29
, pp. 521-534
-
-
Swensson, R.G.1
Judy, P.F.2
-
21
-
-
0022120676
-
Uncertainty explains many aspects of visual contrast and detection discrimination
-
D. G. Pelli, "Uncertainty explains many aspects of visual contrast and detection discrimination," J. Opt. Soc. Am. A , 1508-1532, 1985.
-
(1985)
J. Opt. Soc. Am. A
, pp. 1508-1532
-
-
Pelli, D.G.1
|