메뉴 건너뛰기




Volumn 53, Issue 11, 2008, Pages 1470-1474

Nail polish does not significantly affect pulse oximetry measurements in mildly hypoxic subjects

Author keywords

High altitude; Hypoxia; Nail polish; Pulse oximetry; S pO2

Indexed keywords

OXYGEN; COSMETIC;

EID: 58849106423     PISSN: 00201324     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (18)

References (11)
  • 2
    • 0036139197 scopus 로고    scopus 로고
    • The theory and applications of pulse spectrophotometry
    • Aoyagi T, Miyasaka K. The theory and applications of pulse spectrophotometry. Anesth Analg 2002;94(1 Suppl):S93-S95. (Pubitemid 34033569)
    • (2002) Anesthesia and Analgesia , vol.94 , Issue.1 SUPPL.
    • Aoyagi, T.1    Miyasaka, K.2
  • 3
    • 0022748886 scopus 로고
    • Nail polish does not affect pulse oximeter saturation
    • letter
    • Kataria BK, Lampkins R. Nail polish does not affect pulse oximeter saturation (letter). Anesth Analg 1986;65(7):824.
    • (1986) Anesth Analg , vol.65 , Issue.7 , pp. 824
    • Kataria, B.K.1    Lampkins, R.2
  • 4
    • 0024007626 scopus 로고
    • Nail polish color can affect pulse oximeter saturation
    • letter
    • Rubin AS. Nail polish color can affect pulse oximeter saturation (letter). Anesthesiology 1988;68(5):825.
    • (1988) Anesthesiology , vol.68 , Issue.5 , pp. 825
    • Rubin, A.S.1
  • 6
    • 0024651320 scopus 로고
    • Nail polish and oximetry
    • letter
    • White PF, Boyle WA. Nail polish and oximetry (letter). Anesth Analg 1989;68(4):546-547.
    • (1989) Anesth Analg , vol.68 , Issue.4 , pp. 546-547
    • White, P.F.1    Boyle, W.A.2
  • 7
    • 0024786795 scopus 로고
    • The effect of fingerprinting ink on pulse oximetry
    • DOI 10.1213/00000539-198908000-00031
    • Battito MF. The effect of fingerprinting ink on pulse oximetry (letter). Anesth Analg 1989;69(2):265. (Pubitemid 20045069)
    • (1989) Anesthesia and Analgesia , vol.69 , Issue.2 , pp. 265
    • Battito, M.F.1
  • 8
    • 0035995214 scopus 로고    scopus 로고
    • Enamel nail polish does not interfere with pulse oximetry among normoxic volunteers
    • DOI 10.1023/A:1016385222568
    • Brand TM, Brand ME, Jay GD. Enamel nail polish does not interfere with pulse oximetry among normoxic volunteers. J Clin Monit Comput 2002;17(2):93-96. (Pubitemid 34905098)
    • (2002) Journal of Clinical Monitoring and Computing , vol.17 , Issue.2 , pp. 93-96
    • Brand, T.M.1    Brand, M.E.2    Jay, G.D.3
  • 9
    • 0038724013 scopus 로고    scopus 로고
    • What is the effect of fingernail polish on pulse oximetry?
    • letter
    • Chan MM, Chan MM, Chan ED. What is the effect of fingernail polish on pulse oximetry? (letter). Chest 2003;123(6):2163.
    • (2003) Chest , vol.123 , Issue.6 , pp. 2163
    • Chan, M.M.1    Chan, M.M.2    Chan, E.D.3
  • 10
    • 33845450232 scopus 로고    scopus 로고
    • Effect of nail polish on oxygen saturation determined by pulse oximetry in critically ill patients
    • DOI 10.1016/j.resuscitation.2006.06.024, PII S0300957206003388
    • Hinkelbein J, Genzwuerker HV, Sogl R, Fiedler F. Effect of nail polish on oxygen saturation determined by pulse oximetry in critically ill patients. Resuscitation 2007;72(1):82-91. (Pubitemid 44908769)
    • (2007) Resuscitation , vol.72 , Issue.1 , pp. 82-91
    • Hinkelbein, J.1    Genzwuerker, H.V.2    Sogl, R.3    Fiedler, F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.