메뉴 건너뛰기




Volumn 7, Issue 1, 2009, Pages 293-321

Seismic upgrading of old masonry buildings by seismic isolation and CFRP laminates: A shaking-table study of reduced scale models

Author keywords

CFRP laminate strips; Confinement; Models; Old masonry buildings; Seismic isolation; Seismic resistance; Shaking table tests; Upgrading

Indexed keywords

BUILDINGS; COLUMNS (STRUCTURAL); EARTHQUAKES; FLOORS; FOUNDATIONS; LAMINATES; MASONRY CONSTRUCTION; MASONRY MATERIALS; SEISMOLOGY; TESTING; WOODEN BUILDINGS; WOODEN FLOORS;

EID: 58849097987     PISSN: 1570761X     EISSN: 15731456     Source Type: Journal    
DOI: 10.1007/s10518-008-9086-1     Document Type: Article
Times cited : (42)

References (28)
  • 2
    • 58849157469 scopus 로고
    • Seismic isolation retrofitting: Salt Lake City and County building
    • 2
    • JS Bailey EW Allen 1988 Seismic isolation retrofitting: Salt Lake City and County building APT Bull 20 2 33 34
    • (1988) APT Bull , vol.20 , pp. 33-34
    • Bailey, J.S.1    Allen, E.W.2
  • 3
    • 58849165479 scopus 로고    scopus 로고
    • Increasing available ductility in masonry buildings via energy absorbers. Shaking table tests
    • 3
    • D Benedetti 2004 Increasing available ductility in masonry buildings via energy absorbers. Shaking table tests Eur Earthq Eng 18 3 3 16
    • (2004) Eur Earthq Eng , vol.18 , pp. 3-16
    • Benedetti, D.1
  • 6
    • 58849115609 scopus 로고
    • The sky-scaper of Ljubljana. Care for seismic safety in the 1930-ties
    • Report of FGG no. 38 Ljubljana 5 (in Slovene)
    • Fajfar P (1995) The sky-scaper of Ljubljana. Care for seismic safety in the 1930-ties. Report of FGG no. 38. In: Civil Engineer, Ljubljana, 34 (4-5-6) (in Slovene)
    • (1995) Civil Engineer , vol.34 , Issue.4-6
    • Fajfar, P.1
  • 8
    • 0003215228 scopus 로고    scopus 로고
    • Strengthening unreinforced masonry with FRP
    • Srivastava NK (ed) Elsevier Science Ltd.: Paper No. T119-5 (CD-ROM)
    • Hamilton HR, Dolan CW (1998) Strengthening unreinforced masonry with FRP. In: Srivastava NK (ed) Proceedings, Structural Engineering World Wide, Elsevier Science Ltd.: Paper No. T119-5 (CD-ROM)
    • (1998) Proceedings, Structural Engineering World Wide
    • Hamilton, H.R.1    Dolan, C.W.2
  • 11
    • 6144256005 scopus 로고
    • The shear capacity of membrane type damp-proof courses in masonry
    • 1
    • AW Page 1995 The shear capacity of membrane type damp-proof courses in masonry Aust Civil Eng Trans CE 37 1 29 39
    • (1995) Aust Civil Eng Trans CE , vol.37 , pp. 29-39
    • Page, A.W.1
  • 12
    • 58849138091 scopus 로고    scopus 로고
    • Results from a base-isolated experimental building in Santiago-Chile
    • Sociedad Mexicana de Ingenieria Sismica, A.C. (ed) Acapulco, Pergamon, CD ROM
    • Sarrazin M, Moroni M, Boroschek R, Soto P (1996) Results from a base-isolated experimental building in Santiago-Chile. In: Sociedad Mexicana de Ingenieria Sismica, A.C. (ed) Proceedings, 11th World Conference on Earthquake Engineering, Acapulco, Pergamon, CD ROM
    • (1996) Proceedings, 11th World Conference on Earthquake Engineering
    • Sarrazin, M.1    Moroni, M.2    Boroschek, R.3    Soto, P.4
  • 13
    • 0002342222 scopus 로고
    • Masonry construction strengthened with fiber composites in seismically endangered zones
    • Duma G (ed) Vienna 1994, A.A. Balkema
    • Schwegler G (1995) Masonry construction strengthened with fiber composites in seismically endangered zones. In: Duma G (ed) Proceedings, 10th European Conference on Earthquake Engineering, Vienna 1994, A.A. Balkema
    • (1995) Proceedings, 10th European Conference on Earthquake Engineering
    • Schwegler, G.1
  • 14
    • 58849144014 scopus 로고
    • Dynamic characteristics of tall, pre-1965 masonry buildings, as a basis for their seismic analysis and strengthening
    • University of Bristol, Bristol
    • Sheppard P (1989) Dynamic characteristics of tall, pre-1965 masonry buildings, as a basis for their seismic analysis and strengthening. In: Proceedings, Civil engineering dynamics, University of Bristol, Bristol: 25-42
    • (1989) Proceedings, Civil engineering dynamics , pp. 25-42
    • Sheppard, P.1
  • 15
    • 5644300133 scopus 로고
    • Determination of the seismic resistance of an historical brick-masonry building by laboratory tests of cut-out wall elements
    • Melbourne
    • Sheppard PF, Terčelj S (1985) Determination of the seismic resistance of an historical brick-masonry building by laboratory tests of cut-out wall elements. In: Proceedings, 7th International Brick-Masonry Conference, Vol.2, Melbourne: 1383-1394
    • (1985) Proceedings, 7th International Brick-Masonry Conference , vol.2 , pp. 1383-1394
    • Terčelj Sheppard, S.P.F.1
  • 20
    • 0142172325 scopus 로고    scopus 로고
    • Seismic upgrading of old brick-masonry urban houses: Tying of walls with steel ties
    • 3. 10.1193/1.1585898
    • M Tomaževič M Lutman P Weiss 1996 Seismic upgrading of old brick-masonry urban houses: tying of walls with steel ties Earthq Spectra 12 3 599 622 10.1193/1.1585898
    • (1996) Earthq Spectra , vol.12 , pp. 599-622
    • Tomaževič, M.1    Lutman, M.2    Weiss, P.3
  • 21
    • 84988724916 scopus 로고
    • Aseismic strengthening of historical stone-masonry buildings by building-friendly technologies
    • 1
    • M Tomaževič V Apih M Lutman 1994 Aseismic strengthening of historical stone-masonry buildings by building-friendly technologies Mason Soc J 13 1 41 55
    • (1994) Mason Soc J , vol.13 , pp. 41-55
    • Tomaževič, M.1    Apih, V.2    Lutman, M.3
  • 22
    • 58849160215 scopus 로고
    • The strengthening of stone-masonry walls by injecting the masonry-friendly grouts
    • 1
    • M Tomaževič V Apih 1993 The strengthening of stone-masonry walls by injecting the masonry-friendly grouts Eur Earthq Eng 7 1 10 20
    • (1993) Eur Earthq Eng , vol.7 , pp. 10-20
    • Tomaževič, M.1    Apih, V.2
  • 23
    • 58849088198 scopus 로고
    • Aseismic strengthening of old stone-masonry buildings: Is the replacement of wooden floors with r.c. slabs always necessary?
    • 2
    • M Tomaževič M Lutman T Velechovsky 1993 Aseismic strengthening of old stone-masonry buildings: is the replacement of wooden floors with r.c. slabs always necessary? Eur Earthq Eng 7 2 34 46
    • (1993) Eur Earthq Eng , vol.7 , pp. 34-46
    • Tomaževič, M.1    Lutman, M.2    Velechovsky, T.3
  • 24
    • 18344403060 scopus 로고
    • Dynamic modelling of masonry buildings: Storey mechanism model as a simple alternative
    • 6. 10.1002/eqe.4290150606
    • M Tomaževič 1987 Dynamic modelling of masonry buildings: storey mechanism model as a simple alternative Earthquake Eng Struct Dynam 15 6 731 749 10.1002/eqe.4290150606
    • (1987) Earthquake Eng Struct Dynam , vol.15 , pp. 731-749
    • Tomaževič, M.1
  • 25
    • 0041868039 scopus 로고
    • Some aspects of structural strengthening of historic buildings in urban and rural nuclei against earthquakes
    • 1
    • M Tomaževič 1989 Some aspects of structural strengthening of historic buildings in urban and rural nuclei against earthquakes Eur Earthq Eng 3 1 19 28
    • (1989) Eur Earthq Eng , vol.3 , pp. 19-28
    • Tomaževič, M.1
  • 26
    • 0031251698 scopus 로고    scopus 로고
    • Strengthening of historic masonry structures with composite materials
    • Triantafillou TC, Fardis MN (1997) Strengthening of historic masonry structures with composite materials. Mater Struct 30(10).
    • (1997) Mater Struct , vol.30 , Issue.10
    • Triantafillou, T.C.1    Fardis, M.N.2
  • 27
    • 3242890301 scopus 로고    scopus 로고
    • Seismic retrofitting of structures with fibre-reinforced polymers
    • doi: 10.1002/pse.61
    • Triantafillou TC (2001) Seismic retrofitting of structures with fibre-reinforced polymers. Prog Struct Eng Mater 3(1). doi: 10.1002/pse.61
    • (2001) Prog Struct Eng Mater , vol.3 , Issue.1
    • Triantafillou, T.C.1
  • 28
    • 58849135945 scopus 로고    scopus 로고
    • Optimum design of resilience-friction-slide base isolation system for low cost buildings
    • Sociedad Mexicana de Ingenieria Sismica, A.C. (ed) Acapulco, Pergamon, CD ROM
    • Zhou X, Miao H (1996) Optimum design of resilience-friction-slide base isolation system for low cost buildings. In: Sociedad Mexicana de Ingenieria Sismica, A.C. (ed) Proceedings, 11th World Conference on Earthquake Engineering, Acapulco, Pergamon, CD ROM
    • (1996) Proceedings, 11th World Conference on Earthquake Engineering
    • Zhou, X.1    Miao, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.