메뉴 건너뛰기




Volumn 32, Issue 2, 2009, Pages 149-152

Making sense of the new ICD algorithms for the treatment of fast ventricular tachycardia

Author keywords

[No Author keywords available]

Indexed keywords

DEFIBRILLATOR; EDITORIAL; HEART VENTRICLE FIBRILLATION; HEART VENTRICLE TACHYCARDIA; HUMAN; LONGEVITY; MEDICAL RESEARCH; SINUS RHYTHM; TISSUE DOPPLER IMAGING;

EID: 58849088894     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/j.1540-8159.2008.02195.x     Document Type: Editorial
Times cited : (2)

References (8)
  • 1
    • 0035859949 scopus 로고    scopus 로고
    • Shock reduction using antitachycardia pacing for spontaneous rapid ventricular tachycardia in patients with coronary artery disease
    • PainFREE Investigators.
    • Wathen MS, Sweeney MO, DeGroot PJ, Stark AJ, Koehler JL, Chisner MB, Machado C, et al., PainFREE Investigators. Shock reduction using antitachycardia pacing for spontaneous rapid ventricular tachycardia in patients with coronary artery disease. Circulation 2001 104 : 796 801.
    • (2001) Circulation , vol.104 , pp. 796-801
    • Wathen, M.S.1    Sweeney, M.O.2    Degroot, P.J.3    Stark, A.J.4    Koehler, J.L.5    Chisner, M.B.6    MacHado, C.7
  • 2
    • 7544220287 scopus 로고    scopus 로고
    • Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results
    • PainFREE Rx II Investigators.
    • Wathen MS, DeGroot PJ, Sweeney MO, Stark AJ, Otterness MF, Adkisson WO, Canby RC, et al., PainFREE Rx II Investigators. Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results. Circulation 2004 110 : 2591 2596.
    • (2004) Circulation , vol.110 , pp. 2591-2596
    • Wathen, M.S.1    Degroot, P.J.2    Sweeney, M.O.3    Stark, A.J.4    Otterness, M.F.5    Adkisson, W.O.6    Canby, R.C.7
  • 3
    • 58849134642 scopus 로고    scopus 로고
    • Medtronic Reference Manual for Entrust D153ATG, D153DRG, and D153VRC, Minneapolis MN
    • Medtronic Reference Manual for Entrust D153ATG, D153DRG, and D153VRC, Minneapolis MN, 2006 : 192 233.
    • (2006) , pp. 192-233
  • 4
    • 34250745334 scopus 로고    scopus 로고
    • Optimizing implantable cardioverter-defibrillator treatment of rapid ventricular tachycardia: Antitachycardia pacing therapy during charging
    • EnTrust Clinical Study Investigators.
    • Schoels W, Steinhaus D, Johnson WB, O'hara G, Schwab JO, Jenniskens I, Degroot PJ, et al., EnTrust Clinical Study Investigators. Optimizing implantable cardioverter-defibrillator treatment of rapid ventricular tachycardia: Antitachycardia pacing therapy during charging. Heart Rhythm 2007 4 : 879 885.
    • (2007) Heart Rhythm , vol.4 , pp. 879-885
    • Schoels, W.1    Steinhaus, D.2    Johnson, W.B.3    O'Hara, G.4    Schwab, J.O.5    Jenniskens, I.6    Degroot, P.J.7
  • 5
    • 58849141009 scopus 로고    scopus 로고
    • Antitachycardia Pacing therapy during charging: First experience with a new feature for treating fast ventricular tachycardias in Implantable Cardioverter Defibrillator patients
    • Schwab J, Meijer A, Lobban J, Van Why D, Böcker D, Jenniskens I, Tang F, et al. Antitachycardia Pacing therapy during charging: First experience with a new feature for treating fast ventricular tachycardias in Implantable Cardioverter Defibrillator patients. Heart Rhythm 2006 5 : S31
    • (2006) Heart Rhythm , vol.5
    • Schwab, J.1    Meijer, A.2    Lobban, J.3    Van Why, D.4    Böcker, D.5    Jenniskens, I.6    Tang, F.7
  • 6
    • 58849162916 scopus 로고    scopus 로고
    • ICD versus electrophysiologist classification of ventricular rhythm detected as ventricular fibrillation in PainFREE Rx II (Abstract)
    • Sweeney MO, Whathen MS, Adkisson WO, Machado C, Miller EH, Otterness MF, Stark AJ, et al. ICD versus electrophysiologist classification of ventricular rhythm detected as ventricular fibrillation in PainFREE Rx II (Abstract). Heart Rhythm 2004 1 : S273.
    • (2004) Heart Rhythm , vol.1
    • Sweeney, M.O.1    Whathen, M.S.2    Adkisson, W.O.3    MacHado, C.4    Miller, E.H.5    Otterness, M.F.6    Stark, A.J.7
  • 7
    • 34247369808 scopus 로고    scopus 로고
    • Inappropriate implantable cardioverter-defibrillator discharge associated with a new ventricular tachycardia treatment algorithm
    • Marine JE, Tomaselli GF, Leng CT. Inappropriate implantable cardioverter-defibrillator discharge associated with a new ventricular tachycardia treatment algorithm. Heart Rhythm 2007 4 : 655 657.
    • (2007) Heart Rhythm , vol.4 , pp. 655-657
    • Marine, J.E.1    Tomaselli, G.F.2    Leng, C.T.3
  • 8
    • 33745685677 scopus 로고    scopus 로고
    • A comparison of empiric to physician-tailored programming of implantable cardioverter-defibrillators: Results from the prospective randomized multicenter EMPIRIC trial
    • EMPIRIC Trial Investigators.
    • Wilkoff BL, Ousdigian KT, Sterns LD, Wang ZJ, Wilson RD, Morgan JM, EMPIRIC Trial Investigators. A comparison of empiric to physician-tailored programming of implantable cardioverter-defibrillators: Results from the prospective randomized multicenter EMPIRIC trial. J Am Coll Cardiol 2006 48 : 330 339.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 330-339
    • Wilkoff, B.L.1    Ousdigian, K.T.2    Sterns, L.D.3    Wang, Z.J.4    Wilson, R.D.5    Morgan, J.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.