메뉴 건너뛰기




Volumn 21, Issue 7, 2008, Pages 489-492

Subsidence of titanium mesh cage: A study based on 300 cases

Author keywords

cervical spine; corpectomy; subsidence; titanium mesh cage

Indexed keywords

TITANIUM;

EID: 58749112227     PISSN: 15360652     EISSN: None     Source Type: Journal    
DOI: 10.1097/BSD.0b013e318158de22     Document Type: Article
Times cited : (144)

References (18)
  • 1
    • 0032787868 scopus 로고    scopus 로고
    • Anterior cervical reconstruction using titanium cage with anterior plating
    • Majd ME, Vadhva M, Holt RT. Anterior cervical reconstruction using titanium cage with anterior plating. Spine. 1999;24:1604-1610.
    • (1999) Spine , vol.24 , pp. 1604-1610
    • Majd, M.E.1    Vadhva, M.2    Holt, R.T.3
  • 2
    • 0034665560 scopus 로고    scopus 로고
    • Analysis of titanium mesh cages in adults with minimum two-year follow-up
    • Eck KR, Bridwell KH, Ungacta FF, et al. Analysis of titanium mesh cages in adults with minimum two-year follow-up. Spine. 2000;25: 2407-2415.
    • (2000) Spine , vol.25 , pp. 2407-2415
    • Eck, K.R.1    Bridwell, K.H.2    Ungacta, F.F.3
  • 3
    • 0036143060 scopus 로고    scopus 로고
    • The use of titanium mesh cages in the cervical spine
    • Riew KD, Rhee JM. The use of titanium mesh cages in the cervical spine. Clin Orthop Relat Res. 2002;394:47-54.
    • (2002) Clin Orthop Relat Res , vol.394 , pp. 47-54
    • Riew, K.D.1    Rhee, J.M.2
  • 4
    • 33646051179 scopus 로고    scopus 로고
    • Efficacy and safety of the use of titanium mesh cages and anterior cervical plates for interbody fusion after anterior cervical corpectomy
    • Chuang HC, Cho DY, Chang CS, et al. Efficacy and safety of the use of titanium mesh cages and anterior cervical plates for interbody fusion after anterior cervical corpectomy. Surg Neurol. 2006;65:464-471.
    • (2006) Surg Neurol , vol.65 , pp. 464-471
    • Chuang, H.C.1    Cho, D.Y.2    Chang, C.S.3
  • 5
    • 0035871207 scopus 로고    scopus 로고
    • An experimental study on the interface strength between titanium mesh cage and vertebra in reference to vertebral bone mineral density
    • Hasegawa K, Abe M, Washio T, et al. An experimental study on the interface strength between titanium mesh cage and vertebra in reference to vertebral bone mineral density. Spine. 2001;26:957-963.
    • (2001) Spine , vol.26 , pp. 957-963
    • Hasegawa, K.1    Abe, M.2    Washio, T.3
  • 6
    • 0038206641 scopus 로고    scopus 로고
    • Titanium cage reconstruction after cervical corpectomy
    • Dorai Z, Morgan H, Coimbra C. Titanium cage reconstruction after cervical corpectomy. J Neurosurg. 2003;99(1 suppl):3-7.
    • (2003) J Neurosurg , vol.99 , Issue.1 SUPPL. , pp. 3-7
    • Dorai, Z.1    Morgan, H.2    Coimbra, C.3
  • 7
    • 0141497938 scopus 로고    scopus 로고
    • Titanium mesh cages for cervical spine stabilization after corpectomy: A clinical and radiological study
    • Narotam PK, Pauley SM, McGinn GJ. Titanium mesh cages for cervical spine stabilization after corpectomy: a clinical and radiological study. J Neurosurg. 2003;99(2 suppl):172-180.
    • (2003) J Neurosurg , vol.99 , Issue.2 SUPPL. , pp. 172-180
    • Narotam, P.K.1    Pauley, S.M.2    McGinn, G.J.3
  • 8
    • 0037314769 scopus 로고    scopus 로고
    • Complications of multilevel cervical corpectomies and reconstruction with titanium cages and anterior plating
    • Hee HT, Majd ME, Holt RT, et al. Complications of multilevel cervical corpectomies and reconstruction with titanium cages and anterior plating. J Spinal Disord Tech. 2003;16:1-9.
    • (2003) J Spinal Disord Tech , vol.16 , pp. 1-9
    • Hee, H.T.1    Majd, M.E.2    Holt, R.T.3
  • 9
    • 0346958350 scopus 로고    scopus 로고
    • Pitfalls of anterior cervical fusion using titanium mesh and local autograft
    • Kanayama M, Hashimoto T, Shigenobu K, et al. Pitfalls of anterior cervical fusion using titanium mesh and local autograft. J Spinal Disord Tech. 2003;16:513-518.
    • (2003) J Spinal Disord Tech , vol.16 , pp. 513-518
    • Kanayama, M.1    Hashimoto, T.2    Shigenobu, K.3
  • 10
    • 28044451810 scopus 로고    scopus 로고
    • Anterior cervical interbody fusion with a titanium box cage: Early radiological assessment of fusion and subsidence
    • Van Jonbergen HP, Spruit M, Anderson PG, et al. Anterior cervical interbody fusion with a titanium box cage: early radiological assessment of fusion and subsidence. Spine J. 2005;5:645-649.
    • (2005) Spine J , vol.5 , pp. 645-649
    • Van Jonbergen, H.P.1    Spruit, M.2    Anderson, P.G.3
  • 11
    • 33747157397 scopus 로고    scopus 로고
    • Subsidence of stand-alone cervical carbon fiber cages
    • Bartels RH, Donk RD, Feuth T. Subsidence of stand-alone cervical carbon fiber cages. Neurosurgery. 2006;58:502-508.
    • (2006) Neurosurgery , vol.58 , pp. 502-508
    • Bartels, R.H.1    Donk, R.D.2    Feuth, T.3
  • 12
    • 28744448148 scopus 로고    scopus 로고
    • Early failures following cervical corpectomy reconstruction with titanium mesh cages and anterior plating
    • Daubs MD. Early failures following cervical corpectomy reconstruction with titanium mesh cages and anterior plating. Spine. 2005; 30:1402-1406.
    • (2005) Spine , vol.30 , pp. 1402-1406
    • Daubs, M.D.1
  • 13
    • 0037439134 scopus 로고    scopus 로고
    • Early reconstruction failures after multilevel cervical corpectomy
    • Sasso RC, Ruggiero RA, Reilly TM, et al. Early reconstruction failures after multilevel cervical corpectomy. Spine. 2003;28:140-142.
    • (2003) Spine , vol.28 , pp. 140-142
    • Sasso, R.C.1    Ruggiero, R.A.2    Reilly, T.M.3
  • 14
    • 29444461041 scopus 로고    scopus 로고
    • The transmission of stress to graft bone inside a titanium mesh cage used in anterior column reconstruction after total spondylectomy: A finite-element analysis
    • Akamaru T, Kawahara N, Sakamoto J, et al. The transmission of stress to graft bone inside a titanium mesh cage used in anterior column reconstruction after total spondylectomy: a finite-element analysis. Spine. 2005;30:2783-2787.
    • (2005) Spine , vol.30 , pp. 2783-2787
    • Akamaru, T.1    Kawahara, N.2    Sakamoto, J.3
  • 15
    • 0035870878 scopus 로고    scopus 로고
    • Effect of endplate conditions and bone mineral density on the compressive strength of the graft-endplate interface in anterior cervical fusion
    • Lim TH, Kwon H, Jeon CH, et al. Effect of endplate conditions and bone mineral density on the compressive strength of the graft-endplate interface in anterior cervical fusion. Spine. 2001;26:951-956.
    • (2001) Spine , vol.26 , pp. 951-956
    • Lim, T.H.1    Kwon, H.2    Jeon, C.H.3
  • 16
    • 0347624605 scopus 로고    scopus 로고
    • Anterior correction of cervical kyphotic deformity: Effects on myelopathy, neck pain, and sagittal alignment
    • Spine
    • Ferch RD, Shad A, Cadoux-Hudson TA, et al. Anterior correction of cervical kyphotic deformity: effects on myelopathy, neck pain, and sagittal alignment. J Neurosurg. 2004;100(1 suppl Spine):13-19.
    • (2004) J Neurosurg , vol.100 , Issue.1 SUPPL. , pp. 13-19
    • Ferch, R.D.1    Shad, A.2    Cadoux-Hudson, T.A.3
  • 17
    • 33747843016 scopus 로고    scopus 로고
    • Complications and long-term follow-up results in titanium mesh cage reconstruction after cervical corpectomy
    • Nakase H, Park YS, Kimura H, et al. Complications and long-term follow-up results in titanium mesh cage reconstruction after cervical corpectomy. J Spinal Disord Tech. 2006;19:353-357.
    • (2006) J Spinal Disord Tech , vol.19 , pp. 353-357
    • Nakase, H.1    Park, Y.S.2    Kimura, H.3
  • 18
    • 0034872492 scopus 로고    scopus 로고
    • Use of cylindrical titanium mesh and locking plates in anterior cervical fusion
    • Das K, Couldwell WT, Sava G, et al. Use of cylindrical titanium mesh and locking plates in anterior cervical fusion. J Neurosurg. 2001;94:174-178.
    • (2001) J Neurosurg , vol.94 , pp. 174-178
    • Das, K.1    Couldwell, W.T.2    Sava, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.