Calibration of a high-resolution open-path FTIR spectrometer combined with an adjustable 100-m multipass cell

Author keywords

Calibration; Calibration function; Confidence intervals; Lower detection limit; Open path FTIR; Performance characteristics; Repeatability

Indexed keywords

AIR QUALITY; CURVE FITTING; FOURIER TRANSFORM INFRARED SPECTROSCOPY; FUNCTIONS; LITHIUM BATTERIES; METHANE; PROBABILITY DENSITY FUNCTION; REMOTE SENSING; SPECTROMETERS; SPECTROMETRY; STANDARDIZATION; VEGETATION;

EID: 58749092516     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.274749     Document Type: Conference Paper
Times cited : (5)

References (12)
  • 2
    • 58749116776 scopus 로고    scopus 로고
    • ISO 9169 Air Quality, Determination of performance characteristics of measurement methods 1994
    • ISO 9169 Air Quality - Determination of performance characteristics of measurement methods (1994)
  • 3
    • 58749087033 scopus 로고    scopus 로고
    • VDI: Guideline 2449, Part 1: Determination of performance characteristics for the measurement of gaseous pollutants (Immission); Beuth Verlag, Berlin Ausgabe 02/1995
    • VDI: Guideline 2449, Part 1: Determination of performance characteristics for the measurement of gaseous pollutants (Immission); Beuth Verlag, Berlin Ausgabe 02/1995
  • 4
    • 58749108250 scopus 로고    scopus 로고
    • Calibration of an Open-Path FTIR Spectrometer for Methane, Ethylene and Carbon Monoxide using a fixed 20 m multi pass cell
    • this issue
    • T.Lamp, M.Radmacher and K.Weber, "Calibration of an Open-Path FTIR Spectrometer for Methane, Ethylene and Carbon Monoxide using a fixed 20 m multi pass cell", this issue, 1997
    • (1997)
    • Lamp, T.1    Radmacher, M.2    Weber, K.3
  • 5
    • 58749086875 scopus 로고    scopus 로고
    • VDI Richtlinie 3490, Bl. 17: Herstellung von Prüfgasen unter Verwendung von thermischen Massenstromreglern, Beuth Verlag; Berlin Ausgabe 11/1994 (VDI Guideline 3490, Part 17: Production of calibration gases using thermal mass flow controller)
    • VDI Richtlinie 3490, Bl. 17: Herstellung von Prüfgasen unter Verwendung von thermischen Massenstromreglern, Beuth Verlag; Berlin Ausgabe 11/1994 (VDI Guideline 3490, Part 17: Production of calibration gases using thermal mass flow controller)
  • 6
    • 0020207102 scopus 로고
    • Application of New Least-squares Methods for the Quantitative Infrared Analysis of Multicomponent Samples
    • D.M.Haaland and R.G.Easterling, "Application of New Least-squares Methods for the Quantitative Infrared Analysis of Multicomponent Samples", Applied Spectroscopy, 1982
    • (1982) Applied Spectroscopy
    • Haaland, D.M.1    Easterling, R.G.2
  • 7
    • 0004264421 scopus 로고
    • R.Oldenbourg Verlag, München, 2.Auflage, handbook of statistics
    • K.Bosch, "Statistik Taschenbuch", R.Oldenbourg Verlag, München, 2.Auflage 1993 (handbook of statistics)
    • (1993) Statistik Taschenbuch
    • Bosch, K.1
  • 8
    • 58749100434 scopus 로고    scopus 로고
    • Compendium Method TO-16, Long-Path Open-Path Fourier Transform Infrared Monitoring Of Atmospheric Gases, U.S. Environmental Protection Agency, 1997
    • Compendium Method TO-16, "Long-Path Open-Path Fourier Transform Infrared Monitoring Of Atmospheric Gases", U.S. Environmental Protection Agency, 1997
  • 12
    • 58749115193 scopus 로고    scopus 로고
    • Quality assurance procedure and measurements for Open-Path FTIR spectroscopy
    • this issue
    • M.Douard, J. Zeutius-Reitz, T.Lamp, A.Ropertz, and K.Weber, "Quality assurance procedure and measurements for Open-Path FTIR spectroscopy", this issue, 1997
    • (1997)
    • Douard, M.1    Zeutius-Reitz, J.2    Lamp, T.3    Ropertz, A.4    Weber, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.