Volumn 3032, Issue , 1997, Pages 405-410

Physical model based scatter correction in mammography

Author keywords

Digital radiology; Mammography; Scatter correction

Indexed keywords

DIAGNOSTIC RADIOGRAPHY; IMAGE PROCESSING; RADIATION; RADIOLOGY; SCATTERING; THREE DIMENSIONAL;

EID: 58749087708     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.274008     Document Type: Conference Paper
Times cited : (4)

References (10)
  • 2
    • 0017877595 scopus 로고
    • The intensity of scattered radiation in mammography
    • January
    • Barnes GT, Brezovich IA. The intensity of scattered radiation in mammography. Radiology 126, 243-247, January 1978.
    • (1978) Radiology , vol.126 , pp. 243-247
    • Barnes, G.T.1    Brezovich, I.A.2
  • 4
    • 0023274537 scopus 로고
    • Scatter-glare correction using a convolution algorithm with variable weighting
    • May/Jun
    • Naimuddin S, Hasegawa B, Mistretta CA. Scatter-glare correction using a convolution algorithm with variable weighting. Med. Phys. 14(3), 330-334, May/Jun 1987.
    • (1987) Med. Phys , vol.14 , Issue.3 , pp. 330-334
    • Naimuddin, S.1    Hasegawa, B.2    Mistretta, C.A.3
  • 5
    • 0028182136 scopus 로고
    • A regional convolution kernel algorithm for scatter correction in dual-energy images: Comparison to single-kernel algorithms
    • February
    • Kruger DG, Zink F, Peppler WW, Ergun DL, and Mistretta CA. A regional convolution kernel algorithm for scatter correction in dual-energy images: Comparison to single-kernel algorithms. Med. Phys. 21(2), 175-184, February 1994.
    • (1994) Med. Phys , vol.21 , Issue.2 , pp. 175-184
    • Kruger, D.G.1    Zink, F.2    Peppler, W.W.3    Ergun, D.L.4    Mistretta, C.A.5
  • 6
    • 0023752571 scopus 로고
    • X-ray scatter removal by deconvolution
    • Jul/Aug
    • Seibert JA, and Boone JM. X-ray scatter removal by deconvolution. Med. Phys. 15(4), 567-575, Jul/Aug 1988.
    • (1988) Med. Phys , vol.15 , Issue.4 , pp. 567-575
    • Seibert, J.A.1    Boone, J.M.2
  • 7
    • 0023792394 scopus 로고
    • An analytical model of the scattered radiation distribution in diagnostic radiology
    • Sep/Oct
    • Boone JM, and Seibert JA. An analytical model of the scattered radiation distribution in diagnostic radiology. Med. Phys. 15(5), 721-725, Sep/Oct 1988.
    • (1988) Med. Phys , vol.15 , Issue.5 , pp. 721-725
    • Boone, J.M.1    Seibert, J.A.2
  • 8
    • 0024499762 scopus 로고
    • Scatter compensation in digital chest radiography using Fourier deconvolution
    • January
    • Floyd CE, Beatty PT, and Ravin CE. Scatter compensation in digital chest radiography using Fourier deconvolution. Investigative Radiology 24, 30-33, January 1989.
    • (1989) Investigative Radiology , vol.24 , pp. 30-33
    • Floyd, C.E.1    Beatty, P.T.2    Ravin, C.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.