-
1
-
-
0024548995
-
Induced astigmatism in small incision cataract surgery
-
Shepherd J.R. Induced astigmatism in small incision cataract surgery. J Cataract Refract Surg 15 (1989) 85-88
-
(1989)
J Cataract Refract Surg
, vol.15
, pp. 85-88
-
-
Shepherd, J.R.1
-
2
-
-
0025857257
-
Astigmatism after small incision cataract surgery; a prospective, randomized, multicenter comparison of 4- and 6.5-mm incisions
-
discussion by DD Koch, 423-424; correction 1997; 104:1370
-
Steinert R.F., Brint S.F., White S.M., and Fine I.H. Astigmatism after small incision cataract surgery; a prospective, randomized, multicenter comparison of 4- and 6.5-mm incisions. Ophthalmology 98 (1991) 417-423 discussion by DD Koch, 423-424; correction 1997; 104:1370
-
(1991)
Ophthalmology
, vol.98
, pp. 417-423
-
-
Steinert, R.F.1
Brint, S.F.2
White, S.M.3
Fine, I.H.4
-
3
-
-
0027328018
-
Effect of cataract wound incision size on acute changes in corneal topography
-
Martin R.G., Sanders D.R., Miller J.D., Cox III C.C., and Ballew C. Effect of cataract wound incision size on acute changes in corneal topography. J Cataract Refract Surg 19 (1993) 170-177
-
(1993)
J Cataract Refract Surg
, vol.19
, pp. 170-177
-
-
Martin, R.G.1
Sanders, D.R.2
Miller, J.D.3
Cox III, C.C.4
Ballew, C.5
-
4
-
-
0028954006
-
The correlation between incision size and corneal shape changes in sutureless cataract surgery
-
Hayashi K., Hayashi H., Nakao F., and Hayashi F. The correlation between incision size and corneal shape changes in sutureless cataract surgery. Ophthalmology 102 (1995) 550-556
-
(1995)
Ophthalmology
, vol.102
, pp. 550-556
-
-
Hayashi, K.1
Hayashi, H.2
Nakao, F.3
Hayashi, F.4
-
5
-
-
0032076604
-
Prospective randomized comparison of phacoemulsification cataract surgery with a 3.2-mm vs a 5.5-mm sutureless incision
-
Olson R.J., and Crandall A.S. Prospective randomized comparison of phacoemulsification cataract surgery with a 3.2-mm vs a 5.5-mm sutureless incision. Am J Ophthalmol 125 (1998) 612-620
-
(1998)
Am J Ophthalmol
, vol.125
, pp. 612-620
-
-
Olson, R.J.1
Crandall, A.S.2
-
6
-
-
0027965647
-
Comparative study of intraocular lens implantation through 3.2- and 5.5-mm incisions
-
Oshika T., Tsuboi S., Yaguchi S., Yoshitomi F., Nagamoto T., Nagahara K., and Emi K. Comparative study of intraocular lens implantation through 3.2- and 5.5-mm incisions. Ophthalmology 101 (1994) 1183-1190
-
(1994)
Ophthalmology
, vol.101
, pp. 1183-1190
-
-
Oshika, T.1
Tsuboi, S.2
Yaguchi, S.3
Yoshitomi, F.4
Nagamoto, T.5
Nagahara, K.6
Emi, K.7
-
7
-
-
0034753476
-
Phakonit: phacoemulsification through 0.9 mm corneal incision
-
Agarwal A., Agarwal A., Agarwal S., Narang P., and Narang S. Phakonit: phacoemulsification through 0.9 mm corneal incision. J Cataract Refract Surg 27 (2001) 1548-1552
-
(2001)
J Cataract Refract Surg
, vol.27
, pp. 1548-1552
-
-
Agarwal, A.1
Agarwal, A.2
Agarwal, S.3
Narang, P.4
Narang, S.5
-
8
-
-
0034976611
-
Feasibility of ultrasound cataract surgery with a 1.4 mm incision
-
Tsuneoka H., Shiba T., and Takahashi Y. Feasibility of ultrasound cataract surgery with a 1.4 mm incision. J Cataract Refract Surg 27 (2001) 934-940
-
(2001)
J Cataract Refract Surg
, vol.27
, pp. 934-940
-
-
Tsuneoka, H.1
Shiba, T.2
Takahashi, Y.3
-
9
-
-
0036144095
-
Ultrasonic phacoemulsification using a 1.4 mm incision: clinical results
-
Tsuneoka H., Shiba T., and Takahashi Y. Ultrasonic phacoemulsification using a 1.4 mm incision: clinical results. J Cataract Refract Surg 28 (2002) 81-86
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 81-86
-
-
Tsuneoka, H.1
Shiba, T.2
Takahashi, Y.3
-
10
-
-
0036271758
-
Microphacoemulsification with WhiteStar; a wound-temperature study
-
Soscia W., Howard J.G., and Olson R.J. Microphacoemulsification with WhiteStar; a wound-temperature study. J Cataract Refract Surg 28 (2002) 1044-1046
-
(2002)
J Cataract Refract Surg
, vol.28
, pp. 1044-1046
-
-
Soscia, W.1
Howard, J.G.2
Olson, R.J.3
-
11
-
-
0037974455
-
Efficacy and wound-temperature gradient of WhiteStar phacoemulsification through a 1.2 mm incision
-
Donnenfeld E.D., Olson R.J., Solomon R., Finger P.T., Biser S.A., Perry H.D., and Doshi S. Efficacy and wound-temperature gradient of WhiteStar phacoemulsification through a 1.2 mm incision. J Cataract Refract Surg 29 (2003) 1097-1100
-
(2003)
J Cataract Refract Surg
, vol.29
, pp. 1097-1100
-
-
Donnenfeld, E.D.1
Olson, R.J.2
Solomon, R.3
Finger, P.T.4
Biser, S.A.5
Perry, H.D.6
Doshi, S.7
-
12
-
-
0348010438
-
Feasibility of sleeveless bimanual phacoemulsification with the Millennium microsurgical system
-
Braga-Mele R., and Liu E. Feasibility of sleeveless bimanual phacoemulsification with the Millennium microsurgical system. J Cataract Refract Surg 29 (2003) 2199-2203
-
(2003)
J Cataract Refract Surg
, vol.29
, pp. 2199-2203
-
-
Braga-Mele, R.1
Liu, E.2
-
13
-
-
1842424470
-
Optimizing refractive lens exchange with bimanual microincision phacoemulsification
-
Fine I.H., Hoffman R.S., and Packer M. Optimizing refractive lens exchange with bimanual microincision phacoemulsification. J Cataract Refract Surg 30 (2004) 550-554
-
(2004)
J Cataract Refract Surg
, vol.30
, pp. 550-554
-
-
Fine, I.H.1
Hoffman, R.S.2
Packer, M.3
-
14
-
-
1242296887
-
Clinical experience with 21-gauge manual microphacoemulsification using Sovereign WhiteStar technology in eyes with dense cataract
-
Olson R.J. Clinical experience with 21-gauge manual microphacoemulsification using Sovereign WhiteStar technology in eyes with dense cataract. J Cataract Refract Surg 30 (2004) 168-172
-
(2004)
J Cataract Refract Surg
, vol.30
, pp. 168-172
-
-
Olson, R.J.1
-
15
-
-
33847150012
-
Bimanual microphacoemulsification versus coaxial miniphacoemulsification: prospective study
-
Cavallini G.M., Campi L., Masini C., Pelloni S., and Pupino A. Bimanual microphacoemulsification versus coaxial miniphacoemulsification: prospective study. J Cataract Refract Surg 33 (2007) 387-392
-
(2007)
J Cataract Refract Surg
, vol.33
, pp. 387-392
-
-
Cavallini, G.M.1
Campi, L.2
Masini, C.3
Pelloni, S.4
Pupino, A.5
-
16
-
-
34248638441
-
Intraoperative performance and postoperative outcomes of microcoaxial phacoemulsification; observational study
-
Vasavada V., Vasavada V., Raj S.M., and Vasavada A.R. Intraoperative performance and postoperative outcomes of microcoaxial phacoemulsification; observational study. J Cataract Refract Surg 33 (2007) 1019-1024
-
(2007)
J Cataract Refract Surg
, vol.33
, pp. 1019-1024
-
-
Vasavada, V.1
Vasavada, V.2
Raj, S.M.3
Vasavada, A.R.4
-
17
-
-
38649090994
-
Outcomes of coaxial microincision cataract surgery versus conventional coaxial cataract surgery
-
Dosso A.A., Cottet L., Burgener N.D., and Di Nardo S. Outcomes of coaxial microincision cataract surgery versus conventional coaxial cataract surgery. J Cataract Refract Surg 34 (2008) 284-288
-
(2008)
J Cataract Refract Surg
, vol.34
, pp. 284-288
-
-
Dosso, A.A.1
Cottet, L.2
Burgener, N.D.3
Di Nardo, S.4
-
18
-
-
52049116905
-
Incision sizes before and after implantation of SN60WF intraocular lenses using the Monarch injector system with C and D cartridges
-
Kohnen T., and Klaproth O.K. Incision sizes before and after implantation of SN60WF intraocular lenses using the Monarch injector system with C and D cartridges. J Cataract Refract Surg 34 (2008) 1748-1753
-
(2008)
J Cataract Refract Surg
, vol.34
, pp. 1748-1753
-
-
Kohnen, T.1
Klaproth, O.K.2
-
19
-
-
27644453444
-
Outcomes of microincision cataract surgery versus coaxial phacoemulsification
-
Alió J., Rodríquez-Prats J.L., Galal A., and Ramzy M. Outcomes of microincision cataract surgery versus coaxial phacoemulsification. Ophthalmology 112 (2005) 1997-2003
-
(2005)
Ophthalmology
, vol.112
, pp. 1997-2003
-
-
Alió, J.1
Rodríquez-Prats, J.L.2
Galal, A.3
Ramzy, M.4
-
20
-
-
33748986001
-
Biaxial microincision versus coaxial small-incision clear cornea cataract surgery
-
Kurz S., Krummenauer F., Gabriel P., Pfeiffer N., and Dick H.B. Biaxial microincision versus coaxial small-incision clear cornea cataract surgery. Ophthalmology 113 (2006) 1818-1826
-
(2006)
Ophthalmology
, vol.113
, pp. 1818-1826
-
-
Kurz, S.1
Krummenauer, F.2
Gabriel, P.3
Pfeiffer, N.4
Dick, H.B.5
-
21
-
-
33751097245
-
Corneal astigmatism, high order aberrations, and optical quality after cataract surgery: microincision versus small incision
-
Yao K., Tang X., and Ye P. Corneal astigmatism, high order aberrations, and optical quality after cataract surgery: microincision versus small incision. J Refract Surg 22 (2006) S1079-S1082
-
(2006)
J Refract Surg
, vol.22
-
-
Yao, K.1
Tang, X.2
Ye, P.3
-
23
-
-
20544470514
-
Clear corneal paracentesis: a case of chronic wound leakage in a patient having bimanual phacoemulsification
-
Stratas B.A. Clear corneal paracentesis: a case of chronic wound leakage in a patient having bimanual phacoemulsification. J Cataract Refract Surg 31 (2005) 1075
-
(2005)
J Cataract Refract Surg
, vol.31
, pp. 1075
-
-
Stratas, B.A.1
-
24
-
-
33847160273
-
Corneal wound architecture and integrity after phacoemulsification; evaluation of coaxial, microincision coaxial, and microincision bimanual techniques
-
Berdahl J.P., DeStafeno J.J., and Kim T. Corneal wound architecture and integrity after phacoemulsification; evaluation of coaxial, microincision coaxial, and microincision bimanual techniques. J Cataract Refract Surg 33 (2007) 510-515
-
(2007)
J Cataract Refract Surg
, vol.33
, pp. 510-515
-
-
Berdahl, J.P.1
DeStafeno, J.J.2
Kim, T.3
-
25
-
-
27144507476
-
Endophthalmitis after microincision cataract surgery
-
Chee S.-P., and Bacsal K. Endophthalmitis after microincision cataract surgery. J Cataract Refract Surg 31 (2005) 1834-1835
-
(2005)
J Cataract Refract Surg
, vol.31
, pp. 1834-1835
-
-
Chee, S.-P.1
Bacsal, K.2
-
26
-
-
33744942332
-
Thermal study of bare tips with various system parameters and incision sizes
-
Osher R.H., and Injev V.P. Thermal study of bare tips with various system parameters and incision sizes. J Cataract Refract Surg 32 (2006) 867-872
-
(2006)
J Cataract Refract Surg
, vol.32
, pp. 867-872
-
-
Osher, R.H.1
Injev, V.P.2
-
27
-
-
1842581519
-
Early visual results with the rollable ThinOptX intraocular lens
-
Dogru M., Honda R., Omoto M., Fujishima H., Yagi Y., and Tsubota K. Early visual results with the rollable ThinOptX intraocular lens. J Cataract Refract Surg 30 (2004) 558-565
-
(2004)
J Cataract Refract Surg
, vol.30
, pp. 558-565
-
-
Dogru, M.1
Honda, R.2
Omoto, M.3
Fujishima, H.4
Yagi, Y.5
Tsubota, K.6
-
28
-
-
23944460854
-
Visual outcome of microincision cataract surgery with implantation of an Acri. Smart lens
-
Alió J.L., Rodriguez-Prats J.-L., Vianello A., and Galal A. Visual outcome of microincision cataract surgery with implantation of an Acri. Smart lens. J Cataract Refract Surg 31 (2005) 1549-1556
-
(2005)
J Cataract Refract Surg
, vol.31
, pp. 1549-1556
-
-
Alió, J.L.1
Rodriguez-Prats, J.-L.2
Vianello, A.3
Galal, A.4
-
30
-
-
33645324748
-
Scanning electron microscopic analysis of acrylic intraocular lenses for microincision cataract surgery
-
Mencucci R., Ponchietti C., Nocentini L., Danielli D., and Menchini U. Scanning electron microscopic analysis of acrylic intraocular lenses for microincision cataract surgery. J Cataract Refract Surg 32 (2006) 318-323
-
(2006)
J Cataract Refract Surg
, vol.32
, pp. 318-323
-
-
Mencucci, R.1
Ponchietti, C.2
Nocentini, L.3
Danielli, D.4
Menchini, U.5
-
32
-
-
40949142767
-
Performance of the Acri. Smart 46S intraocular lens in pediatric microincision cataract surgery
-
Grueterich M., Lackerbauer C.A., and Kampik A. Performance of the Acri. Smart 46S intraocular lens in pediatric microincision cataract surgery. J Cataract Refract Surg 34 (2008) 591-595
-
(2008)
J Cataract Refract Surg
, vol.34
, pp. 591-595
-
-
Grueterich, M.1
Lackerbauer, C.A.2
Kampik, A.3
-
33
-
-
45449089438
-
Prevention of anterior capsule contraction by anterior capsule relaxing incisions with neodymium:yttrium-aluminum-garnet laser
-
Hayashi K., Yoshida M., Nakao F., and Hayashi H. Prevention of anterior capsule contraction by anterior capsule relaxing incisions with neodymium:yttrium-aluminum-garnet laser. Am J Ophthalmol 146 (2008) 23-30
-
(2008)
Am J Ophthalmol
, vol.146
, pp. 23-30
-
-
Hayashi, K.1
Yoshida, M.2
Nakao, F.3
Hayashi, H.4
-
34
-
-
0001407285
-
The pathophysiology of corneal astigmatism after cataract extraction
-
Jaffe N.S., and Clayman H.M. The pathophysiology of corneal astigmatism after cataract extraction. Trans Am Acad Ophthalmol Otolaryngol 79 (1975) OP615-OP630
-
(1975)
Trans Am Acad Ophthalmol Otolaryngol
, vol.79
-
-
Jaffe, N.S.1
Clayman, H.M.2
-
35
-
-
0033772861
-
Fourier analysis of irregular astigmatism after implantation of 3 types of intraocular lenses
-
Hayashi K., Hayashi H., Oshika T., and Hayashi F. Fourier analysis of irregular astigmatism after implantation of 3 types of intraocular lenses. J Cataract Refract Surg 26 (2000) 1510-1516
-
(2000)
J Cataract Refract Surg
, vol.26
, pp. 1510-1516
-
-
Hayashi, K.1
Hayashi, H.2
Oshika, T.3
Hayashi, F.4
-
36
-
-
33746067112
-
Corneal endothelial damage after cataract surgery: microincision versus standard technique
-
Mencucci R., Ponchietti C., Virgili G., Giansanti F., and Menchini U. Corneal endothelial damage after cataract surgery: microincision versus standard technique. J Cataract Refract Surg 32 (2006) 1351-1354
-
(2006)
J Cataract Refract Surg
, vol.32
, pp. 1351-1354
-
-
Mencucci, R.1
Ponchietti, C.2
Virgili, G.3
Giansanti, F.4
Menchini, U.5
-
37
-
-
33947604936
-
Intraindividual comparison of surgical trauma after bimanual microincision and conventional small-incision coaxial phacoemulsification
-
Kahraman G., Amon M., Franz C., Prinz A., and Abela-Formanek C. Intraindividual comparison of surgical trauma after bimanual microincision and conventional small-incision coaxial phacoemulsification. J Cataract Refract Surg 33 (2007) 618-622
-
(2007)
J Cataract Refract Surg
, vol.33
, pp. 618-622
-
-
Kahraman, G.1
Amon, M.2
Franz, C.3
Prinz, A.4
Abela-Formanek, C.5
|