메뉴 건너뛰기




Volumn 15, Issue 1, 2009, Pages

Influence of endotracheal tube bore on tidal volume during high frequency oscillatory ventilation: A model lung study

Author keywords

ARDS; High frequency oscillatory ventilation; Mechanical ventilation

Indexed keywords

ADULT; AIRWAY PRESSURE; ARTICLE; ENDOTRACHEAL TUBE; HIGH FREQUENCY VENTILATION; HUMAN; INSPIRATORY CAPACITY; LUNG COMPLIANCE; OSCILLATION; POSITIVE END EXPIRATORY PRESSURE; TIDAL VOLUME;

EID: 58649099176     PISSN: 12341010     EISSN: 16433750     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (7)

References (20)
  • 1
    • 0019901840 scopus 로고
    • Ventilation at high respiratory frequencies
    • Smith RB: Ventilation at high respiratory frequencies. Anaesthesia, 1982; 37(10): 1011-18
    • (1982) Anaesthesia , vol.37 , Issue.10 , pp. 1011-1018
    • Smith, R.B.1
  • 2
    • 2642674967 scopus 로고
    • Oscillatory mechanics: The pressure cost of high-frequency ventilation
    • Boynton BR, Carlo WA, Jobe AH, eds:, New York: Cambridge University Press
    • Venegas JG, Fredberg JJ: Oscillatory mechanics: The pressure cost of high-frequency ventilation. In: Boynton BR, Carlo WA, Jobe AH, eds: New Therapies for Neonatal Respiratory Failure: A Physiologic Approach. New York: Cambridge University Press, 1994: 192-201
    • (1994) New Therapies for Neonatal Respiratory Failure: A Physiologic Approach , pp. 192-201
    • Venegas, J.G.1    Fredberg, J.J.2
  • 3
    • 0019493706 scopus 로고
    • Treatment of RDS by high-frequency oscillatory ventilation: A preliminary report
    • Marchak BE, Thompson WK, Duffy P et al: Treatment of RDS by high-frequency oscillatory ventilation: A preliminary report. J Pediatr, 1981; 99(2): 287-91
    • (1981) J Pediatr , vol.99 , Issue.2 , pp. 287-291
    • Marchak, B.E.1    Thompson, W.K.2    Duffy, P.3
  • 4
    • 0034958902 scopus 로고    scopus 로고
    • Prospective trial of high-frequency oscillation in patients with acute respiratory distress syndrome
    • Mehta S, Lapinsky SE, Hallett DC et al: Prospective trial of high-frequency oscillation in patients with acute respiratory distress syndrome. Crit Care Med, 2001; 29(7): 1360-69
    • (2001) Crit Care Med , vol.29 , Issue.7 , pp. 1360-1369
    • Mehta, S.1    Lapinsky, S.E.2    Hallett, D.C.3
  • 5
    • 0034807671 scopus 로고    scopus 로고
    • Comparison of lung protection strategies using conventional and high-frequency oscillatory ventilation
    • Imai Y, Nakagawa S, Ito Y et al: Comparison of lung protection strategies using conventional and high-frequency oscillatory ventilation. J Appl Physiol, 2001; 91(4): 1836-44
    • (2001) J Appl Physiol , vol.91 , Issue.4 , pp. 1836-1844
    • Imai, Y.1    Nakagawa, S.2    Ito, Y.3
  • 6
    • 0037194716 scopus 로고    scopus 로고
    • High-frequency oscillatory ventilation versus conventional mechanical ventilation for very-low-birth-weight infants
    • Courtney SE, Durand DJ, Asselin JM et al: High-frequency oscillatory ventilation versus conventional mechanical ventilation for very-low-birth-weight infants. N Engl J Med, 2002; 347(9): 643-52
    • (2002) N Engl J Med , vol.347 , Issue.9 , pp. 643-652
    • Courtney, S.E.1    Durand, D.J.2    Asselin, J.M.3
  • 7
    • 0027431295 scopus 로고
    • Role of tidal volume: FRC, and end-inspiratory volume in the development of pulmonary edema following mechanical ventilation
    • Dreyfuss D, Saumon G: Role of tidal volume: FRC, and end-inspiratory volume in the development of pulmonary edema following mechanical ventilation. Am Rev Respir Dis, 1993; 148(5): 1194-203
    • (1993) Am Rev Respir Dis , vol.148 , Issue.5 , pp. 1194-1203
    • Dreyfuss, D.1    Saumon, G.2
  • 8
    • 0028350295 scopus 로고
    • Tidal ventilation at low airway pressures can augment lung injury
    • Muscedere G, Mullen JBM, Gan K et al: Tidal ventilation at low airway pressures can augment lung injury. Am J Respir Crit Care Med, 1994; 149(5): 1327-34
    • (1994) Am J Respir Crit Care Med , vol.149 , Issue.5 , pp. 1327-1334
    • Muscedere, G.1    Mullen, J.B.M.2    Gan, K.3
  • 9
    • 0345436055 scopus 로고    scopus 로고
    • Effect of mechanical ventilation on inflammatory mediators in patients with acute respiratory distress syndrome: A randomized controlled trial
    • Ranieri VM, Suter PM, Tortorella C et al: Effect of mechanical ventilation on inflammatory mediators in patients with acute respiratory distress syndrome: A randomized controlled trial. JAMA, 1999; 282(1): 54-61
    • (1999) JAMA , vol.282 , Issue.1 , pp. 54-61
    • Ranieri, V.M.1    Suter, P.M.2    Tortorella, C.3
  • 10
    • 0032484956 scopus 로고    scopus 로고
    • Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome
    • Amato MBP, Barbas CSV, Medeiros DM et al: Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome. N Engl J Med, 1998; 338(6): 347-54
    • (1998) N Engl J Med , vol.338 , Issue.6 , pp. 347-354
    • Amato, M.B.P.1    Barbas, C.S.V.2    Medeiros, D.M.3
  • 11
    • 0343893748 scopus 로고    scopus 로고
    • The acute respiratory distress syndrome network: Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome
    • The acute respiratory distress syndrome network: Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med, 2000; 342(18): 1301-8
    • (2000) N Engl J Med , vol.342 , Issue.18 , pp. 1301-1308
  • 12
    • 0030967622 scopus 로고    scopus 로고
    • High-frequency oscillatory ventilation for adult respiratory distress syndrome - A pilot study
    • Fort P, Farmer C, Westerman J et al: High-frequency oscillatory ventilation for adult respiratory distress syndrome - A pilot study. Crit Care Med, 1997; 25(6): 937-47
    • (1997) Crit Care Med , vol.25 , Issue.6 , pp. 937-947
    • Fort, P.1    Farmer, C.2    Westerman, J.3
  • 13
    • 0037106260 scopus 로고    scopus 로고
    • High-frequency oscillatory ventilation for acute respiratory distress syndrome in adults. A randomized, controlled trial
    • Derdak S, Mehta S, Stewart TE et al: High-frequency oscillatory ventilation for acute respiratory distress syndrome in adults. A randomized, controlled trial. Am J Respir Crit Care Med, 2002; 166(6): 801-8
    • (2002) Am J Respir Crit Care Med , vol.166 , Issue.6 , pp. 801-808
    • Derdak, S.1    Mehta, S.2    Stewart, T.E.3
  • 14
    • 58649113646 scopus 로고    scopus 로고
    • Tidal volume evaluation in two high-frequency oscillators for adult patients using a model lung with a position sensor [abstract]
    • Iguchi N, Fujino Y, Hirao O et al: Tidal volume evaluation in two high-frequency oscillators for adult patients using a model lung with a position sensor [abstract]. Respiratory Care, 2004; 49: 1417
    • (2004) Respiratory Care , vol.49 , pp. 1417
    • Iguchi, N.1    Fujino, Y.2    Hirao, O.3
  • 15
    • 0019786969 scopus 로고
    • 2 elimination in dogs by high frequency (2-30 Hz), low tidal volume ventilation
    • 2 elimination in dogs by high frequency (2-30 Hz), low tidal volume ventilation. J Clin Invest, 1981; 68(6): 1475-84
    • (1981) J Clin Invest , vol.68 , Issue.6 , pp. 1475-1484
    • Slutsky, A.S.1    Kamm, R.D.2    Rossing, T.H.3
  • 16
    • 0024513898 scopus 로고
    • Gas exchange in healthy rabbits during high-frequency oscillatory ventilation
    • Boynton BR, Hammond MD, Fredberg JJ et al: Gas exchange in healthy rabbits during high-frequency oscillatory ventilation. J Appl Physiol, 1989; 66(3): 1343-51
    • (1989) J Appl Physiol , vol.66 , Issue.3 , pp. 1343-1351
    • Boynton, B.R.1    Hammond, M.D.2    Fredberg, J.J.3
  • 17
    • 0037250751 scopus 로고    scopus 로고
    • Determinants of tidal volume during high-frequency oscillation
    • Sedeek KA, Takeuchi M, Suchodolski K et al: Determinants of tidal volume during high-frequency oscillation. Crit Care Med 2003; 31(1): 227-31
    • (2003) Crit Care Med , vol.31 , Issue.1 , pp. 227-231
    • Sedeek, K.A.1    Takeuchi, M.2    Suchodolski, K.3
  • 18
    • 0031746090 scopus 로고    scopus 로고
    • Mechanical performance of clinically available, neonatal, high-frequency, oscillatory-type ventilators
    • Hatcher D, Watanabe H, Ashbury T, et al: Mechanical performance of clinically available, neonatal, high-frequency, oscillatory-type ventilators. Crit Care Med, 1998; 26(6): 1081-8
    • (1998) Crit Care Med , vol.26 , Issue.6 , pp. 1081-1088
    • Hatcher, D.1    Watanabe, H.2    Ashbury, T.3
  • 19
    • 0025276981 scopus 로고
    • Measurement of tidal volume using a pneumotachometer during high frequency oscillation
    • Courtney SD, Weber KR, Spohn WA et al: Measurement of tidal volume using a pneumotachometer during high frequency oscillation. Crit Care Med, 1990; 18(6): 651-53
    • (1990) Crit Care Med , vol.18 , Issue.6 , pp. 651-653
    • Courtney, S.D.1    Weber, K.R.2    Spohn, W.A.3
  • 20
    • 34249326214 scopus 로고    scopus 로고
    • Tidal volume delivery during high-frequency oscillatory ventilation in adults with acute respiratory distress syndrome
    • Hager DN, Fessler HE, Kaczka DW et al: Tidal volume delivery during high-frequency oscillatory ventilation in adults with acute respiratory distress syndrome. Crit Care Med, 2007; 35(6): 1522-29
    • (2007) Crit Care Med , vol.35 , Issue.6 , pp. 1522-1529
    • Hager, D.N.1    Fessler, H.E.2    Kaczka, D.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.