메뉴 건너뛰기




Volumn 67, Issue 3, 2009, Pages 393-398

The history and principles of chemical dosimetry for 3-D radiation fields: Gels, polymers and plastics

Author keywords

3 D dosimetry; Gel dosimetry; IMRT; Laser scanner; Optical CT; PRESAGE; Radiotherapy

Indexed keywords

COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC RADIOGRAPHY; DOSIMETERS; ELECTRIC INSTRUMENT TRANSFORMERS; GELATION; GELS; LASER APPLICATIONS; MEDICAL IMAGING; OPTICAL DATA PROCESSING; PHYSICAL THERAPY; POLYMERS; RADIATION CHEMISTRY; RADIOLOGY; RADIOTHERAPY; SCANNING; THREE DIMENSIONAL; TOMOGRAPHY;

EID: 58549117097     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apradiso.2008.06.026     Document Type: Article
Times cited : (82)

References (48)
  • 1
    • 33646451808 scopus 로고    scopus 로고
    • New 3D radiochromic solid polymer dosimeter from leuco dyes and a transparent polymeric matrix
    • Adamovics J., and Maryanski M.J. New 3D radiochromic solid polymer dosimeter from leuco dyes and a transparent polymeric matrix. Med. Phys. 30 6 (2003) 1349
    • (2003) Med. Phys. , vol.30 , Issue.6 , pp. 1349
    • Adamovics, J.1    Maryanski, M.J.2
  • 2
    • 33947432456 scopus 로고    scopus 로고
    • PRESAGETM-development and optimization studies of a 3D radiochromic plastic dosimeter– Part 2
    • Adamovics J., Guo P., Burgess D., Manzoor A., and Oldham M. PRESAGETM-development and optimization studies of a 3D radiochromic plastic dosimeter– Part 2. J. Phys. Conf. Ser. (2006) 176
    • (2006) J. Phys. Conf. Ser. , pp. 176
    • Adamovics, J.1    Guo, P.2    Burgess, D.3    Manzoor, A.4    Oldham, M.5
  • 3
    • 34447308256 scopus 로고    scopus 로고
    • X-ray CT dose in normoxic polyacrylamide gel dosimetry
    • Baxter P., Jirasek A., and Hilts M. X-ray CT dose in normoxic polyacrylamide gel dosimetry. Med. Phys. 34 6 (2007) 1934-1943
    • (2007) Med. Phys. , vol.34 , Issue.6 , pp. 1934-1943
    • Baxter, P.1    Jirasek, A.2    Hilts, M.3
  • 6
    • 58549103647 scopus 로고    scopus 로고
    • Conklin, J., Deshpande, R., Battista, J.J., Jordan, K.J., 2006. Fast laser optical CT scanner with rotating mirror and Fresnel lenses. In: DOSGEL 2006, Fourth International Conference on Radiotherapy Gel Dosimetry, Sherbrooke.
    • Conklin, J., Deshpande, R., Battista, J.J., Jordan, K.J., 2006. Fast laser optical CT scanner with rotating mirror and Fresnel lenses. In: DOSGEL 2006, Fourth International Conference on Radiotherapy Gel Dosimetry, Sherbrooke.
  • 7
    • 58549117807 scopus 로고    scopus 로고
    • Crescenti, R.A., 2006. Personal communication.
    • Crescenti, R.A., 2006. Personal communication.
  • 8
    • 35948976610 scopus 로고    scopus 로고
    • Characterization of the ultrasonic attenuation coefficient and its frequency dependence in a polymer gel dosimeter
    • Crescenti R.A., Bamber J.C., Partridge M., Bush N.L., and Webb S. Characterization of the ultrasonic attenuation coefficient and its frequency dependence in a polymer gel dosimeter. Phys. Med. Biol. 22 (2007) 6747
    • (2007) Phys. Med. Biol. , vol.22 , pp. 6747
    • Crescenti, R.A.1    Bamber, J.C.2    Partridge, M.3    Bush, N.L.4    Webb, S.5
  • 9
    • 23744493616 scopus 로고    scopus 로고
    • Essential characteristics of polymer gel dosimeters
    • de Deene Y. Essential characteristics of polymer gel dosimeters. J. Phys. Conf. Ser. 3 (2004) 34-57
    • (2004) J. Phys. Conf. Ser. , vol.3 , pp. 34-57
    • de Deene, Y.1
  • 10
    • 58549098661 scopus 로고    scopus 로고
    • De Jean, P., Senden, R., McAuley, K., Rogers, M., Schreiner, L.J., 2006a. Initial experience with a commercial cone beam Optical CT unit for polymer gel dosimetry I: optical dosimetry issues. In: DOSGEL 2006, Fourth International Conference on Radiotherapy Gel Dosimetry, Sherbrooke.
    • De Jean, P., Senden, R., McAuley, K., Rogers, M., Schreiner, L.J., 2006a. Initial experience with a commercial cone beam Optical CT unit for polymer gel dosimetry I: optical dosimetry issues. In: DOSGEL 2006, Fourth International Conference on Radiotherapy Gel Dosimetry, Sherbrooke.
  • 11
    • 58549090826 scopus 로고    scopus 로고
    • De Jean, P., Senden, R., McAuley, K., Rogers, M., Schreiner, L.J., 2006b. Initial experience with a commercial cone beam optical CT unit for polymer gel dosimetry II: clinical potential. In: DOSGEL 2006, Fourth International Conference on Radiotherapy Gel Dosimetry, Sherbrooke.
    • De Jean, P., Senden, R., McAuley, K., Rogers, M., Schreiner, L.J., 2006b. Initial experience with a commercial cone beam optical CT unit for polymer gel dosimetry II: clinical potential. In: DOSGEL 2006, Fourth International Conference on Radiotherapy Gel Dosimetry, Sherbrooke.
  • 12
    • 33947360800 scopus 로고    scopus 로고
    • The history and principles of optical computed tomography for scanning 3-D radiation dosimeters
    • Doran S.J., and Krstajic N. The history and principles of optical computed tomography for scanning 3-D radiation dosimeters. J. Phys. Conf. Ser. 56 (2006) 45-57
    • (2006) J. Phys. Conf. Ser. , vol.56 , pp. 45-57
    • Doran, S.J.1    Krstajic, N.2
  • 13
    • 0035739240 scopus 로고    scopus 로고
    • A CCD-based optical CT scanner for high-resolution 3D imaging of radiation dose distributions: equipment specifications, optical simulations and preliminary results
    • Doran S.J., Koerkamp K.K., Bero M.A., Jenneson P., Morton E.J., and Gilboy W.B. A CCD-based optical CT scanner for high-resolution 3D imaging of radiation dose distributions: equipment specifications, optical simulations and preliminary results. Phys. Med. Biol. 46 12 (2001) 3191-3213
    • (2001) Phys. Med. Biol. , vol.46 , Issue.12 , pp. 3191-3213
    • Doran, S.J.1    Koerkamp, K.K.2    Bero, M.A.3    Jenneson, P.4    Morton, E.J.5    Gilboy, W.B.6
  • 14
    • 58549113930 scopus 로고    scopus 로고
    • DOSGEL, 2004. Proceedings of the third international conference on radiotherapy gel dosimetry. In: DOSGEL, Ghent.
    • DOSGEL, 2004. Proceedings of the third international conference on radiotherapy gel dosimetry. In: DOSGEL, Ghent.
  • 15
    • 33947412370 scopus 로고    scopus 로고
    • Effect of container size on the accuracy of polymer gel dosimetry
    • Dumas E.-M., Leclerc G., and Lepage M. Effect of container size on the accuracy of polymer gel dosimetry. J. Phys. Conf. Ser. 239 (2006)
    • (2006) J. Phys. Conf. Ser. , vol.239
    • Dumas, E.-M.1    Leclerc, G.2    Lepage, M.3
  • 16
    • 58549102255 scopus 로고    scopus 로고
    • Gilboy, W.B., 1996. Private communication.
    • Gilboy, W.B., 1996. Private communication.
  • 17
    • 0021232591 scopus 로고
    • Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imaging
    • Gore J.C., Kang Y.S., and Schulz R.J. Measurement of radiation dose distributions by nuclear magnetic resonance (NMR) imaging. Phys. Med. Biol. 29 10 (1984) 1189-1197
    • (1984) Phys. Med. Biol. , vol.29 , Issue.10 , pp. 1189-1197
    • Gore, J.C.1    Kang, Y.S.2    Schulz, R.J.3
  • 18
    • 0029838960 scopus 로고    scopus 로고
    • Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: I. Development of an optical scanner
    • Gore J.C., Ranade M., and Maryanski M.J. Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: I. Development of an optical scanner. Phys. Med. Biol. 41 12 (1996) 2695-2704
    • (1996) Phys. Med. Biol. , vol.41 , Issue.12 , pp. 2695-2704
    • Gore, J.C.1    Ranade, M.2    Maryanski, M.J.3
  • 19
    • 49549158048 scopus 로고
    • Absorption characteristics of xylenol orange
    • Gupta B.L. Absorption characteristics of xylenol orange. Talanta 21 6 (1974) 683-684
    • (1974) Talanta , vol.21 , Issue.6 , pp. 683-684
    • Gupta, B.L.1
  • 20
    • 0017892660 scopus 로고
    • Radiation-chemistry of ferrous sulfate benzoic-acid xylenol orange system
    • Gupta B.L., Bhat R.M., Gomathy K.R., and Susheela B. Radiation-chemistry of ferrous sulfate benzoic-acid xylenol orange system. Rad. Res. 75 2 (1978) 269-277
    • (1978) Rad. Res. , vol.75 , Issue.2 , pp. 269-277
    • Gupta, B.L.1    Bhat, R.M.2    Gomathy, K.R.3    Susheela, B.4
  • 21
    • 0026761359 scopus 로고
    • Use of the Fbx dosimeter for the quality assurance of Co-60 and high-energy teletherapy machines by mail
    • Gupta B.L., Narayan G.R., Bhat R.M., Kini U.R., Ramaswamy R.S., and Suseela B. Use of the Fbx dosimeter for the quality assurance of Co-60 and high-energy teletherapy machines by mail. Phys. Med. Biol. 37 11 (1992) 2095-2102
    • (1992) Phys. Med. Biol. , vol.37 , Issue.11 , pp. 2095-2102
    • Gupta, B.L.1    Narayan, G.R.2    Bhat, R.M.3    Kini, U.R.4    Ramaswamy, R.S.5    Suseela, B.6
  • 22
    • 33947429079 scopus 로고    scopus 로고
    • Acceptance testing of a computer tomography scanner using normoxic polymer gel dosimtery
    • Hill B., Venning A., and Baldock C. Acceptance testing of a computer tomography scanner using normoxic polymer gel dosimtery. Med. Phys. 31 6 (2004) 1786
    • (2004) Med. Phys. , vol.31 , Issue.6 , pp. 1786
    • Hill, B.1    Venning, A.2    Baldock, C.3
  • 23
    • 21144437851 scopus 로고    scopus 로고
    • A preliminary study of the novel application of normoxic polymer gel dosimeters for the measurement of CTDI on diagnostic X-ray CT scanners
    • Hill B., Venning A.J., and Baldock C. A preliminary study of the novel application of normoxic polymer gel dosimeters for the measurement of CTDI on diagnostic X-ray CT scanners. Med. Phys. 32 6 (2005) 1589-1597
    • (2005) Med. Phys. , vol.32 , Issue.6 , pp. 1589-1597
    • Hill, B.1    Venning, A.J.2    Baldock, C.3
  • 24
    • 58549089633 scopus 로고    scopus 로고
    • Investigating dose resolution in CT polymer gel dosimetry
    • Hilts M., Duzenli C., and Jirasek A. Investigating dose resolution in CT polymer gel dosimetry. Med. Phys. 32 7 (2005) 2427
    • (2005) Med. Phys. , vol.32 , Issue.7 , pp. 2427
    • Hilts, M.1    Duzenli, C.2    Jirasek, A.3
  • 25
    • 22844443764 scopus 로고    scopus 로고
    • Technical considerations for implementation of X-ray CT polymer gel dosimetry
    • Hilts M., Jirasek A., and Duzenli C. Technical considerations for implementation of X-ray CT polymer gel dosimetry. Phys. Med. Biol. 50 8 (2005) 1727-1745
    • (2005) Phys. Med. Biol. , vol.50 , Issue.8 , pp. 1727-1745
    • Hilts, M.1    Jirasek, A.2    Duzenli, C.3
  • 27
    • 58549098463 scopus 로고    scopus 로고
    • ICRU I C o R U 1993. Report 50: prescribing, recording and reporting photon beam therapy.
    • ICRU I C o R U 1993. Report 50: prescribing, recording and reporting photon beam therapy.
  • 28
    • 58549115832 scopus 로고    scopus 로고
    • IPEM, 2002. Medical and dental guidance notes. A Good Practice Guide on All Aspects of Ionising Radiation Protection in the Clinical Environment.
    • IPEM, 2002. Medical and dental guidance notes. A Good Practice Guide on All Aspects of Ionising Radiation Protection in the Clinical Environment.
  • 29
    • 33947421307 scopus 로고    scopus 로고
    • Jordan, K., Battista, J., 2006. Linearity and image uniformity of the Vista™ optical cone beam scanner. In: DOSGEL 2006, Fourth International Conference on Radiotherapy Gel Dosimetry, Sherbrooke.
    • Jordan, K., Battista, J., 2006. Linearity and image uniformity of the Vista™ optical cone beam scanner. In: DOSGEL 2006, Fourth International Conference on Radiotherapy Gel Dosimetry, Sherbrooke.
  • 31
    • 34547133466 scopus 로고    scopus 로고
    • Dose integration characteristics in normoxic polymer gel dosimetry investigated using sequential beam irradiation
    • Karlsson A., Gustavsson H., Månsson S., McAuley K.B., and Bäck S.J. Dose integration characteristics in normoxic polymer gel dosimetry investigated using sequential beam irradiation. Phys. Med. Biol. 15 (2007) 4697
    • (2007) Phys. Med. Biol. , vol.15 , pp. 4697
    • Karlsson, A.1    Gustavsson, H.2    Månsson, S.3    McAuley, K.B.4    Bäck, S.J.5
  • 32
    • 0031691208 scopus 로고    scopus 로고
    • Optical CT reconstruction of 3D dose distributions using the ferrous-benzoic-xylenol (FBX) gel dosimeter
    • Kelly R.G., Jordan K.J., and Battista J.J. Optical CT reconstruction of 3D dose distributions using the ferrous-benzoic-xylenol (FBX) gel dosimeter. Med. Phys. 25 9 (1998) 1741-1750
    • (1998) Med. Phys. , vol.25 , Issue.9 , pp. 1741-1750
    • Kelly, R.G.1    Jordan, K.J.2    Battista, J.J.3
  • 33
    • 33645551817 scopus 로고    scopus 로고
    • Focusing optics of a parallel beam CCD optical tomography apparatus for 3D radiation dosimetry
    • Krstajic N., and Doran S.J. Focusing optics of a parallel beam CCD optical tomography apparatus for 3D radiation dosimetry. Phys. Med. Biol. 51 8 (2006) 2055-2075
    • (2006) Phys. Med. Biol. , vol.51 , Issue.8 , pp. 2055-2075
    • Krstajic, N.1    Doran, S.J.2
  • 34
    • 34250353175 scopus 로고    scopus 로고
    • Characterization of a parallel-beam CCD optical-CT apparatus for 3D radiation dosimetry
    • Krstajic N., and Doran S.J. Characterization of a parallel-beam CCD optical-CT apparatus for 3D radiation dosimetry. Phys. Med. Biol. 52 13 (2007) 3693-3713
    • (2007) Phys. Med. Biol. , vol.52 , Issue.13 , pp. 3693-3713
    • Krstajic, N.1    Doran, S.J.2
  • 35
    • 34249063332 scopus 로고    scopus 로고
    • Krstajic, N., Doran, S.J., 2007b. Fast laser scanning optical-CT apparatus for 3D radiation dosimetry. Phys. Med. Biol. 52 (11), N257-NN63.
    • Krstajic, N., Doran, S.J., 2007b. Fast laser scanning optical-CT apparatus for 3D radiation dosimetry. Phys. Med. Biol. 52 (11), N257-NN63.
  • 37
    • 0027258459 scopus 로고
    • NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: a new approach to 3D dosimetry by MRI
    • Maryanski M.J., Gore J.C., Kennan R.P., and Schulz R.J. NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: a new approach to 3D dosimetry by MRI. Magn. Reson. Imag. 11 2 (1993) 253-258
    • (1993) Magn. Reson. Imag. , vol.11 , Issue.2 , pp. 253-258
    • Maryanski, M.J.1    Gore, J.C.2    Kennan, R.P.3    Schulz, R.J.4
  • 38
    • 58549120299 scopus 로고    scopus 로고
    • Investigation of PAG and MAGIC polymer gel dosimeters using ultrasound
    • Mather M., De Deene Y., Whittaker A., and Baldock C. Investigation of PAG and MAGIC polymer gel dosimeters using ultrasound. Med. Phys. 29 6 (2002) 1370-1371
    • (2002) Med. Phys. , vol.29 , Issue.6 , pp. 1370-1371
    • Mather, M.1    De Deene, Y.2    Whittaker, A.3    Baldock, C.4
  • 39
    • 33745868593 scopus 로고    scopus 로고
    • The chemistry and physics of polymer gel dosimeters: why they do and don't work
    • McAuley K. The chemistry and physics of polymer gel dosimeters: why they do and don't work. J. Phys. Conf. Ser. 3 (2004) 29-33
    • (2004) J. Phys. Conf. Ser. , vol.3 , pp. 29-33
    • McAuley, K.1
  • 40
    • 0032806772 scopus 로고    scopus 로고
    • Dynamics of polymerization in polyacrylamide gel (PAG) dosimeters: (I) ageing and long-term stability
    • McJury M., Oldham M., Leach M.O., and Webb S. Dynamics of polymerization in polyacrylamide gel (PAG) dosimeters: (I) ageing and long-term stability. Phys. Med. Biol. 44 8 (1999) 1863-1873
    • (1999) Phys. Med. Biol. , vol.44 , Issue.8 , pp. 1863-1873
    • McJury, M.1    Oldham, M.2    Leach, M.O.3    Webb, S.4
  • 41
    • 0034912917 scopus 로고    scopus 로고
    • High resolution gel-dosimetry by optical-CT and MR scanning
    • Oldham M., Siewerdsen J.H., Shetty A., and Jaffray D.A. High resolution gel-dosimetry by optical-CT and MR scanning. Med. Phys. 28 7 (2001) 1436-1445
    • (2001) Med. Phys. , vol.28 , Issue.7 , pp. 1436-1445
    • Oldham, M.1    Siewerdsen, J.H.2    Shetty, A.3    Jaffray, D.A.4
  • 42
    • 58549105250 scopus 로고    scopus 로고
    • Parodi, K., 2003. Data processing techniques for in-beam PET therapy monitoring.
    • Parodi, K., 2003. Data processing techniques for in-beam PET therapy monitoring.
  • 43
    • 32644466259 scopus 로고    scopus 로고
    • Review of Fricke gel dosimeters
    • Schreiner L.J. Review of Fricke gel dosimeters. J. Phys. Conf. Ser. 3 (2004) 9-21
    • (2004) J. Phys. Conf. Ser. , vol.3 , pp. 9-21
    • Schreiner, L.J.1
  • 44
    • 4444355803 scopus 로고    scopus 로고
    • Optical projection tomography
    • Sharpe J. Optical projection tomography. Ann. Rev. Biomed. Eng. 6 (2004) 209-228
    • (2004) Ann. Rev. Biomed. Eng. , vol.6 , pp. 209-228
    • Sharpe, J.1
  • 46
    • 21444456875 scopus 로고    scopus 로고
    • Quantitative optical tomography of chemical waves and their organizing centers
    • Winfree A.T., Caudle S., Chen G., McGuire P., and Szilagyi Z. Quantitative optical tomography of chemical waves and their organizing centers. Chaos 6 4 (1996) 617-626
    • (1996) Chaos , vol.6 , Issue.4 , pp. 617-626
    • Winfree, A.T.1    Caudle, S.2    Chen, G.3    McGuire, P.4    Szilagyi, Z.5
  • 47
    • 0032692176 scopus 로고    scopus 로고
    • CCD imaging for optical tomography of gel radiation dosimeters
    • Wolodzko J.G., Marsden C., and Appleby A. CCD imaging for optical tomography of gel radiation dosimeters. Med. Phys. 26 11 (1999) 2508-2513
    • (1999) Med. Phys. , vol.26 , Issue.11 , pp. 2508-2513
    • Wolodzko, J.G.1    Marsden, C.2    Appleby, A.3
  • 48
    • 0037320142 scopus 로고    scopus 로고
    • Dosimetry study of Re-188 liquid balloon for intravascular brachytherapy using polymer gel dosimeters and laser-beam optical CT scanner
    • Wuu C.S., Schiff P., Maryanski M.J., Liu T., Borzillary S., and Weinberger J. Dosimetry study of Re-188 liquid balloon for intravascular brachytherapy using polymer gel dosimeters and laser-beam optical CT scanner. Med. Phys. 30 2 (2003) 132-137
    • (2003) Med. Phys. , vol.30 , Issue.2 , pp. 132-137
    • Wuu, C.S.1    Schiff, P.2    Maryanski, M.J.3    Liu, T.4    Borzillary, S.5    Weinberger, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.