Comparison of radiation doses between cone beam CT and multi detector CT: TLD measurements

Author keywords

[No Author keywords available]

Indexed keywords


EID: 58549116744     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/ncn305     Document Type: Article
Times cited : (36)

References (15)
  • 1
    • 0034086714 scopus 로고    scopus 로고
    • Cone-beam computed tomography with a flat-panel imager: Initial performance characterization
    • Jaffray, D. A. and Siewerdsen, J. H. Cone-beam computed tomography with a flat-panel imager: Initial performance characterization. Med. Phys. 27, 1311-1323 (2000).
    • (2000) Med. Phys , vol.27 , pp. 1311-1323
    • Jaffray, D.A.1    Siewerdsen, J.H.2
  • 2
    • 17844409887 scopus 로고    scopus 로고
    • Enlarged longitudinal dose profiles in cone-beam CT and the need for modified dosimetry
    • Mori, S., Endo, M., Nishizawa, K., Tsunoo, T., Aoyama, T., Fujiwara, H. and Murase, K. Enlarged longitudinal dose profiles in cone-beam CT and the need for modified dosimetry. Med. Phys. 32, 1061-1069 (2005).
    • (2005) Med. Phys , vol.32 , pp. 1061-1069
    • Mori, S.1    Endo, M.2    Nishizawa, K.3    Tsunoo, T.4    Aoyama, T.5    Fujiwara, H.6    Murase, K.7
  • 3
    • 34147107446 scopus 로고    scopus 로고
    • The trouble with CTDI100
    • Boone, J. M. The trouble with CTDI100. Med. Phys. 34, 1364-1371 (2007).
    • (2007) Med. Phys , vol.34 , pp. 1364-1371
    • Boone, J.M.1
  • 4
    • 0038038881 scopus 로고    scopus 로고
    • A new look at CT dose measurement: Beyond CTDI
    • Dixon, R. L. A new look at CT dose measurement: Beyond CTDI. Med. Phys. 30, 1272-1280 (2003).
    • (2003) Med. Phys , vol.30 , pp. 1272-1280
    • Dixon, R.L.1
  • 5
    • 0019485556 scopus 로고
    • A method for describing the doses delivered by transmission x-ray computed tomography
    • Shope, T. B., Gagne, R. M. and Johnson, G. C. A method for describing the doses delivered by transmission x-ray computed tomography. Med. Phys. 8, 488-495 (1981).
    • (1981) Med. Phys , vol.8 , pp. 488-495
    • Shope, T.B.1    Gagne, R.M.2    Johnson, G.C.3
  • 6
    • 12844262152 scopus 로고    scopus 로고
    • Novel methods of measuring single scan dose profiles and cumulative dose in CT
    • Nakonechny, K. D., Fallone, B. G. and Rathee, S. Novel methods of measuring single scan dose profiles and cumulative dose in CT. Med. Phys. 32, 98-109 (2005).
    • (2005) Med. Phys , vol.32 , pp. 98-109
    • Nakonechny, K.D.1    Fallone, B.G.2    Rathee, S.3
  • 8
    • 33750568952 scopus 로고    scopus 로고
    • A quality assurance program for the on-board imager R
    • Yoo, S. et al. A quality assurance program for the on-board imager R. Med. Phys. 33(11), 4431-4447 (2006).
    • (2006) Med. Phys , vol.33 , Issue.11 , pp. 4431-4447
    • Yoo, S.1
  • 9
    • 34247606356 scopus 로고    scopus 로고
    • Validation of metal oxide semiconductor field effect transistor technology for organ dose assessment during CT: Comparison with thermoluminescent dosimetry
    • Yoshizumi, T. T., Goodman, P. C., Frush, D. P., Nguyen, G., Toncheva, G., Sarder, M. and Barnes, L. Validation of metal oxide semiconductor field effect transistor technology for organ dose assessment during CT: comparison with thermoluminescent dosimetry. Am. J. Roentgenol. 188, 1332-1336 (2007).
    • (2007) Am. J. Roentgenol , vol.188 , pp. 1332-1336
    • Yoshizumi, T.T.1    Goodman, P.C.2    Frush, D.P.3    Nguyen, G.4    Toncheva, G.5    Sarder, M.6    Barnes, L.7
  • 11
    • 0037380211 scopus 로고    scopus 로고
    • Multidetector vs single detector CT: Comparison of radiation dose and dose profile
    • Thornton, F. J., Paulson, E. K., Yoshizumi, T. T., Frush, D. P. and Nelson, R. C. Multidetector vs single detector CT: Comparison of radiation dose and dose profile. Acad. Radiol. 10, 379-385 (2003).
    • (2003) Acad. Radiol , vol.10 , pp. 379-385
    • Thornton, F.J.1    Paulson, E.K.2    Yoshizumi, T.T.3    Frush, D.P.4    Nelson, R.C.5
  • 12
    • 0033856280 scopus 로고    scopus 로고
    • Measurement of half-value layer in x-ray CT: A comparison of two noninvasive techniques
    • Kruger, R. L., McCollough, C. H. and Zink, F. E. Measurement of half-value layer in x-ray CT: A comparison of two noninvasive techniques Med Phys. 27, 1915-1919 (2000).
    • (2000) Med Phys , vol.27 , pp. 1915-1919
    • Kruger, R.L.1    McCollough, C.H.2    Zink, F.E.3
  • 13
    • 0004266385 scopus 로고
    • second edn, Chicago, IL, USA: Year Book Medical Publishers, Inc, p
    • Hendee, W. R. Medical Radiation Physics. second edn. (Chicago, IL, USA: Year Book Medical Publishers, Inc.) p. 171 (1979).
    • (1979) Medical Radiation Physics , pp. 171
    • Hendee, W.R.1
  • 14
    • 85167021891 scopus 로고    scopus 로고
    • Murphy, M. J. et al. The management of imaging dose during image-guided radiotherapy: Report of the AAPM task group 75. Med. Phys. 34, 4041-4063 (2007).
    • Murphy, M. J. et al. The management of imaging dose during image-guided radiotherapy: Report of the AAPM task group 75. Med. Phys. 34, 4041-4063 (2007).
  • 15
    • 47649088991 scopus 로고    scopus 로고
    • A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction
    • Xu, X. G., Bednarz, B. and Paganett, H. A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction. Phys. Med. Biol. 53, R193-R241 (2008).
    • (2008) Phys. Med. Biol , vol.53
    • Xu, X.G.1    Bednarz, B.2    Paganett, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.