Cone-beam computed tomography with a flat-panel imager: Initial performance characterization
-
Jaffray, D. A. and Siewerdsen, J. H. Cone-beam computed tomography with a flat-panel imager: Initial performance characterization. Med. Phys. 27, 1311-1323 (2000).
-
(2000)
Med. Phys
, vol.27
, pp. 1311-1323
-
-
Jaffray, D.A.1
Siewerdsen, J.H.2
-
2
-
-
17844409887
-
Enlarged longitudinal dose profiles in cone-beam CT and the need for modified dosimetry
-
Mori, S., Endo, M., Nishizawa, K., Tsunoo, T., Aoyama, T., Fujiwara, H. and Murase, K. Enlarged longitudinal dose profiles in cone-beam CT and the need for modified dosimetry. Med. Phys. 32, 1061-1069 (2005).
-
(2005)
Med. Phys
, vol.32
, pp. 1061-1069
-
-
Mori, S.1
Endo, M.2
Nishizawa, K.3
Tsunoo, T.4
Aoyama, T.5
Fujiwara, H.6
Murase, K.7
-
3
-
-
34147107446
-
The trouble with CTDI100
-
Boone, J. M. The trouble with CTDI100. Med. Phys. 34, 1364-1371 (2007).
-
(2007)
Med. Phys
, vol.34
, pp. 1364-1371
-
-
Boone, J.M.1
-
4
-
-
0038038881
-
A new look at CT dose measurement: Beyond CTDI
-
Dixon, R. L. A new look at CT dose measurement: Beyond CTDI. Med. Phys. 30, 1272-1280 (2003).
-
(2003)
Med. Phys
, vol.30
, pp. 1272-1280
-
-
Dixon, R.L.1
-
5
-
-
0019485556
-
A method for describing the doses delivered by transmission x-ray computed tomography
-
Shope, T. B., Gagne, R. M. and Johnson, G. C. A method for describing the doses delivered by transmission x-ray computed tomography. Med. Phys. 8, 488-495 (1981).
-
(1981)
Med. Phys
, vol.8
, pp. 488-495
-
-
Shope, T.B.1
Gagne, R.M.2
Johnson, G.C.3
-
6
-
-
12844262152
-
Novel methods of measuring single scan dose profiles and cumulative dose in CT
-
Nakonechny, K. D., Fallone, B. G. and Rathee, S. Novel methods of measuring single scan dose profiles and cumulative dose in CT. Med. Phys. 32, 98-109 (2005).
-
(2005)
Med. Phys
, vol.32
, pp. 98-109
-
-
Nakonechny, K.D.1
Fallone, B.G.2
Rathee, S.3
-
7
-
-
38849155750
-
A dose comparison study between XVI® and OBI® CBCT systems
-
Song, W. Y., Kamath, S., Ozawa, S., Ani, S. A., Chvetsov, A., Bhandare, N., Palta, J. R., Liu, C. and Li, J. G. A dose comparison study between XVI® and OBI® CBCT systems. Med. Phys. 35, 480-486 (2008).
-
(2008)
Med. Phys
, vol.35
, pp. 480-486
-
-
Song, W.Y.1
Kamath, S.2
Ozawa, S.3
Ani, S.A.4
Chvetsov, A.5
Bhandare, N.6
Palta, J.R.7
Liu, C.8
Li, J.G.9
-
8
-
-
33750568952
-
A quality assurance program for the on-board imager R
-
Yoo, S. et al. A quality assurance program for the on-board imager R. Med. Phys. 33(11), 4431-4447 (2006).
-
(2006)
Med. Phys
, vol.33
, Issue.11
, pp. 4431-4447
-
-
Yoo, S.1
-
9
-
-
34247606356
-
Validation of metal oxide semiconductor field effect transistor technology for organ dose assessment during CT: Comparison with thermoluminescent dosimetry
-
Yoshizumi, T. T., Goodman, P. C., Frush, D. P., Nguyen, G., Toncheva, G., Sarder, M. and Barnes, L. Validation of metal oxide semiconductor field effect transistor technology for organ dose assessment during CT: comparison with thermoluminescent dosimetry. Am. J. Roentgenol. 188, 1332-1336 (2007).
-
(2007)
Am. J. Roentgenol
, vol.188
, pp. 1332-1336
-
-
Yoshizumi, T.T.1
Goodman, P.C.2
Frush, D.P.3
Nguyen, G.4
Toncheva, G.5
Sarder, M.6
Barnes, L.7
-
10
-
-
33645830944
-
Radiation exposure to the fetus from body MDCT during early gestation
-
Hurwitz, L. M., Yoshizumi, T. T., Reiman, R. E., Goodman, P. C., Paulson, E. K., Frush, D. P., Nguyen, G., Toncheva, G. and Barnes, L. Radiation exposure to the fetus from body MDCT during early gestation Am. J. Roentgenol. 186, 871-876 (2006).
-
(2006)
Am. J. Roentgenol
, vol.186
, pp. 871-876
-
-
Hurwitz, L.M.1
Yoshizumi, T.T.2
Reiman, R.E.3
Goodman, P.C.4
Paulson, E.K.5
Frush, D.P.6
Nguyen, G.7
Toncheva, G.8
Barnes, L.9
-
11
-
-
0037380211
-
Multidetector vs single detector CT: Comparison of radiation dose and dose profile
-
Thornton, F. J., Paulson, E. K., Yoshizumi, T. T., Frush, D. P. and Nelson, R. C. Multidetector vs single detector CT: Comparison of radiation dose and dose profile. Acad. Radiol. 10, 379-385 (2003).
-
(2003)
Acad. Radiol
, vol.10
, pp. 379-385
-
-
Thornton, F.J.1
Paulson, E.K.2
Yoshizumi, T.T.3
Frush, D.P.4
Nelson, R.C.5
-
12
-
-
0033856280
-
Measurement of half-value layer in x-ray CT: A comparison of two noninvasive techniques
-
Kruger, R. L., McCollough, C. H. and Zink, F. E. Measurement of half-value layer in x-ray CT: A comparison of two noninvasive techniques Med Phys. 27, 1915-1919 (2000).
-
(2000)
Med Phys
, vol.27
, pp. 1915-1919
-
-
Kruger, R.L.1
McCollough, C.H.2
Zink, F.E.3
-
13
-
-
0004266385
-
-
second edn, Chicago, IL, USA: Year Book Medical Publishers, Inc, p
-
Hendee, W. R. Medical Radiation Physics. second edn. (Chicago, IL, USA: Year Book Medical Publishers, Inc.) p. 171 (1979).
-
(1979)
Medical Radiation Physics
, pp. 171
-
-
Hendee, W.R.1
-
14
-
-
85167021891
-
-
Murphy, M. J. et al. The management of imaging dose during image-guided radiotherapy: Report of the AAPM task group 75. Med. Phys. 34, 4041-4063 (2007).
-
Murphy, M. J. et al. The management of imaging dose during image-guided radiotherapy: Report of the AAPM task group 75. Med. Phys. 34, 4041-4063 (2007).
-
-
-
-
15
-
-
47649088991
-
A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction
-
Xu, X. G., Bednarz, B. and Paganett, H. A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction. Phys. Med. Biol. 53, R193-R241 (2008).
-
(2008)
Phys. Med. Biol
, vol.53
-
-
Xu, X.G.1
Bednarz, B.2
Paganett, H.3
|