메뉴 건너뛰기




Volumn 63, Issue 1-2, 2009, Pages 87-95

Polymeric membrane and coated graphite electrode based on newly synthesized tetraazamacrocyclic ligand for trace level determination of nickel ion in fruit juices and wine samples

Author keywords

Chemical sensors; Coated graphite electrode; Ion selective electrodes; Nickel selective sensor; Tetraazamacrocycle

Indexed keywords


EID: 58549115892     PISSN: 09230750     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10847-008-9492-7     Document Type: Article
Times cited : (4)

References (47)
  • 3
    • 0032099044 scopus 로고    scopus 로고
    • Carrier based ion-selective electrode and bulk optodes. 2. Ionophores for potentiometric and optical sensors
    • 10.1021/cr970113+
    • P Buhlmann E Pretsch E Bakker 1998 Carrier based ion-selective electrode and bulk optodes. 2. Ionophores for potentiometric and optical sensors Chem. Rev. 98 1593 1687 10.1021/cr970113+
    • (1998) Chem. Rev. , vol.98 , pp. 1593-1687
    • Buhlmann, P.1    Pretsch, E.2    Bakker, E.3
  • 4
    • 0000793113 scopus 로고
    • Double armed crown ethers and armed macrocycle as a new series of metal selective reagents; A review
    • 10.1016/0039-9140(93)80204-5
    • H Tsukube 1993 Double armed crown ethers and armed macrocycle as a new series of metal selective reagents; a review Talanta 40 1313 1324 10.1016/0039-9140(93)80204-5
    • (1993) Talanta , vol.40 , pp. 1313-1324
    • Tsukube, H.1
  • 5
    • 0035973248 scopus 로고    scopus 로고
    • Synthesis and properties of nickel(II) and copper(II) complexes of a di-N-acetamidetetraaza macrocycle
    • 10.1016/S0277-5387(01)00801-4
    • KY Choi HY Lee B Park JH Kim J Kim MW Kim 2001 Synthesis and properties of nickel(II) and copper(II) complexes of a di-N-acetamidetetraaza macrocycle Polyhedron 20 2003 2009 10.1016/S0277-5387(01)00801-4
    • (2001) Polyhedron , vol.20 , pp. 2003-2009
    • Choi, K.Y.1    Lee, H.Y.2    Park, B.3    Kim, J.H.4    Kim, J.5    Kim, M.W.6
  • 6
    • 0035820141 scopus 로고    scopus 로고
    • Macrocyclic ligand design, X-Ray, DFT and solution studies of the effect of N-methylation and N-benzylation of 1,4,10,13-tetraoxa-7,16- diazacyclooctadecane on its affinity for selected transition and post-transition metal ions
    • doi: 10.1039/b008789k
    • Hambley, T.W., Lindoy, L.F., Reimers, J.R., Turner, P., Wei, W., Cooper, A.N.W.: Macrocyclic ligand design, X-Ray, DFT and solution studies of the effect of N-methylation and N-benzylation of 1,4,10,13-tetraoxa-7,16- diazacyclooctadecane on its affinity for selected transition and post-transition metal ions. J. Chem. Soc., Dalton Trans. 614-620 (2001). doi: 10.1039/b008789k
    • (2001) J. Chem. Soc., Dalton Trans. , pp. 614-620
    • Hambley, T.W.1    Lindoy, L.F.2    Reimers, J.R.3    Turner, P.4    Wei, W.5    Cooper, A.N.W.6
  • 7
    • 0036499899 scopus 로고    scopus 로고
    • Synthesis of and magnetic interaction in binuclear copper(II)-M(II) (M = Cu, Ni, Mn) complexes of macrocyclic oxaamido ligands
    • 10.1016/S0277-5387(01)01002-6
    • EQ Gao HY Sun HYDZ Liao ZH Jiang SP Yan 2002 Synthesis of and magnetic interaction in binuclear copper(II)-M(II) (M = Cu, Ni, Mn) complexes of macrocyclic oxaamido ligands Polyhedron 21 359 364 10.1016/S0277-5387(01)01002-6
    • (2002) Polyhedron , vol.21 , pp. 359-364
    • Gao, E.Q.1    Sun, H.Y.2    Hydz, L.3    Jiang, Z.H.4    Yan, S.P.5
  • 8
    • 0036013814 scopus 로고    scopus 로고
    • Macrocyclic ligand design. Structure-function relationship involving the interaction of pyridyl-containing, mixed oxygen-nitrogen donor macrocycles with cobalt(II), nickel(II), copper(II), zinc(II), cadmium (II), silver(I) and lead(II)
    • doi: 10.1039/b201195f
    • Fenton, R.R., Gauci, R., Junk, P.C., Lindoy, L.F., Luckay, R.C., Meehan, G.V., et al.: Macrocyclic ligand design. Structure-function relationship involving the interaction of pyridyl-containing, mixed oxygen-nitrogen donor macrocycles with cobalt(II), nickel(II), copper(II), zinc(II), cadmium (II), silver(I) and lead(II). J. Chem. Soc., Dalton Trans. 2185-2193 (2002). doi: 10.1039/b201195f
    • (2002) J. Chem. Soc., Dalton Trans. , pp. 2185-2193
    • Fenton, R.R.1    Gauci, R.2    Junk, P.C.3    Lindoy, L.F.4    Luckay, R.C.5    Meehan, G.V.6
  • 9
    • 0036536995 scopus 로고    scopus 로고
    • Twelve-, fourteen- and sixteen membered macrocyclic ligands and a study of the effect of ring size on ligand field strength
    • 10.1023/A:1013935602736
    • S Chandra K Gupta 2002 Twelve-, fourteen- and sixteen membered macrocyclic ligands and a study of the effect of ring size on ligand field strength Transit. Metal Chem. 27 196 199 10.1023/A:1013935602736
    • (2002) Transit. Metal Chem. , vol.27 , pp. 196-199
    • Chandra, S.1    Gupta, K.2
  • 12
    • 0030668846 scopus 로고    scopus 로고
    • Porphyrins as carrier in PVC based membrane potentiometric sensors for nickel(II)
    • 10.1016/S0003-2670(97)81609-1
    • VK Gupta AK Jain LP Singh U Khurana 1997 Porphyrins as carrier in PVC based membrane potentiometric sensors for nickel(II) Anal. Chim. Acta 335 33 41 10.1016/S0003-2670(97)81609-1
    • (1997) Anal. Chim. Acta , vol.335 , pp. 33-41
    • Gupta, V.K.1    Jain, A.K.2    Singh, L.P.3    Khurana, U.4
  • 13
    • 0002767290 scopus 로고    scopus 로고
    • Nickel selective electrode based on nickel-dimethylglyoxime complex in silicone rubber
    • E Pungor K Toth J Havas 1996 Nickel selective electrode based on nickel-dimethylglyoxime complex in silicone rubber Acta Chir. Acad. Sci. Hung 48 17 23
    • (1996) Acta Chir. Acad. Sci. Hung , vol.48 , pp. 17-23
    • Pungor, E.1    Toth, K.2    Havas, J.3
  • 14
    • 0000159076 scopus 로고
    • Heterogeneous ion-selective electrodes based on electroneutral ion carriers: Barium(II) and nickel(II) electrodes
    • US Lal MC Chattopadhayaya AK Dey 1982 Heterogeneous ion-selective electrodes based on electroneutral ion carriers: barium(II) and nickel(II) electrodes J. Ind. Chem. Soc. 59 493 496
    • (1982) J. Ind. Chem. Soc. , vol.59 , pp. 493-496
    • Lal, U.S.1    Chattopadhayaya, M.C.2    Dey, A.K.3
  • 16
    • 0001233083 scopus 로고
    • Study of impregnated silicone rubber membranes for potential indicating electrodes
    • 10.1021/ac60259a027
    • EB Buchanan JL Saego 1968 Study of impregnated silicone rubber membranes for potential indicating electrodes Anal. Chem. 40 517 521 10.1021/ac60259a027
    • (1968) Anal. Chem. , vol.40 , pp. 517-521
    • Buchanan, E.B.1    Saego, J.L.2
  • 17
    • 0031131389 scopus 로고    scopus 로고
    • Nickel(II) selective sensors based on heterogeneous membrane of macrocyclic compounds
    • 10.1016/S0925-4005(97)80193-1
    • AK Jain VK Gupta RD Singh U Khurana LP Singh 1997 Nickel(II) selective sensors based on heterogeneous membrane of macrocyclic compounds Sens. Actuators B Chem. 40 15 20 10.1016/S0925-4005(97)80193-1
    • (1997) Sens. Actuators B Chem. , vol.40 , pp. 15-20
    • Jain, A.K.1    Gupta, V.K.2    Singh, R.D.3    Khurana, U.4    Singh, L.P.5
  • 18
    • 0010965150 scopus 로고    scopus 로고
    • Nickel(II) selective membrane electrode based on macrocyclic ligand
    • doi :10.1002/1521-4109(200110)13:14〈1209::AID-ELAN1209〉3.0. CO;2-N
    • Singh, A.K., Sharma, C.L., Baniwal, S., Panwar, A.: Nickel(II) selective membrane electrode based on macrocyclic ligand. Electroanalysis 13, 1209-1214 (2001). doi :10.1002/1521-4109(200110)13:14〈1209::AID-ELAN1209〉3.0. CO;2-N
    • (2001) Electroanalysis , vol.13 , pp. 1209-1214
    • Singh, A.K.1    Sharma, C.L.2    Baniwal, S.3    Panwar, A.4
  • 19
    • 33846649573 scopus 로고    scopus 로고
    • A PVC based membrane electrode for nickel(II) ions incorporating a tetraazamacrocycle as an ionophore
    • 10.1016/j.snb.2006.03.043
    • AK Singh P Saxena 2007 A PVC based membrane electrode for nickel(II) ions incorporating a tetraazamacrocycle as an ionophore Sens. Actuators B Chem. 121 349 355 10.1016/j.snb.2006.03.043
    • (2007) Sens. Actuators B Chem. , vol.121 , pp. 349-355
    • Singh, A.K.1    Saxena, P.2
  • 20
    • 0034618790 scopus 로고    scopus 로고
    • New nickel(II) selective potentiometric sensor based on 5,7,12,14-tetramethyl-dibenzotetraazaannulene in a poly(vinyl chloride) matrix
    • 10.1016/S0003-2670(00)01013-8
    • VK Gupta R Prasad P Kumar R Mangla 2000 New nickel(II) selective potentiometric sensor based on 5,7,12,14-tetramethyl-dibenzotetraazaannulene in a poly(vinyl chloride) matrix Anal. Chim. Acta 420 19 27 10.1016/S0003-2670(00) 01013-8
    • (2000) Anal. Chim. Acta , vol.420 , pp. 19-27
    • Gupta, V.K.1    Prasad, R.2    Kumar, P.3    Mangla, R.4
  • 21
    • 0037185999 scopus 로고    scopus 로고
    • Pentacyclooctaaza as a neutral carrier in coated wire ion-selective electrode for nickel(II)
    • 10.1016/S0925-4005(01)01017-6
    • M Mazloum MS Niassary MK Amini 2002 Pentacyclooctaaza as a neutral carrier in coated wire ion-selective electrode for nickel(II) Sens. Actuators B Chem. 82 259 264 10.1016/S0925-4005(01)01017-6
    • (2002) Sens. Actuators B Chem. , vol.82 , pp. 259-264
    • Mazloum, M.1    Niassary, M.S.2    Amini, M.K.3
  • 23
    • 0042091974 scopus 로고    scopus 로고
    • Nickel(II) selective membrane potentiometric sensor using a recently synthesized Schiff base as neutral carrier
    • 10.1016/S0925-4005(03)00449-0
    • MH Mashhadizadeh I Sheikhshoaie S Saeid-Nia 2003 Nickel(II) selective membrane potentiometric sensor using a recently synthesized Schiff base as neutral carrier Sens. Actuators B Chem. 94 241 246 10.1016/S0925-4005(03)00449-0
    • (2003) Sens. Actuators B Chem. , vol.94 , pp. 241-246
    • Mashhadizadeh, M.H.1    Sheikhshoaie, I.2    Saeid-Nia, S.3
  • 24
    • 0037413572 scopus 로고    scopus 로고
    • Nickel(II) selective membrane potentiometric sensor using a recently synthesized mercapto compound as a neutral carrier
    • 10.1016/S0039-9140(02)00462-9
    • MH Mashhadizadeh A Momeni 2003 Nickel(II) selective membrane potentiometric sensor using a recently synthesized mercapto compound as a neutral carrier Talanta 59 47 53 10.1016/S0039-9140(02)00462-9
    • (2003) Talanta , vol.59 , pp. 47-53
    • Mashhadizadeh, M.H.1    Momeni, A.2
  • 25
    • 4143132939 scopus 로고    scopus 로고
    • 2+ ion using carboxylated and methylated porphine
    • 10.1109/JSEN.2003.815795
    • 2+ ion using carboxylated and methylated porphine Sensors 3 393 403 10.1109/JSEN.2003.815795
    • (2003) Sensors , vol.3 , pp. 393-403
    • Singh, L.P.1    Bhatnagar, J.M.2
  • 26
    • 0036097687 scopus 로고    scopus 로고
    • Nickel ion selective coated graphite PVC membrane electrode based on benzylbis(thiosemicarbazone)
    • doi :10.1002/1521-4109(200204)14:7/8〈526::AID-ELAN526〉3.0.CO;2- O
    • Ganjali, M.R., Hosseini, S.M., Salavati-Niasari, M., Poursaberi, T., Shamsipur, M., Javanbakht, M., et al.: Nickel ion selective coated graphite PVC membrane electrode based on benzylbis(thiosemicarbazone). Electroanalysis 14, 526-531 (2002). doi :10.1002/1521-4109(200204)14:7/8〈526::AID- ELAN526〉3.0.CO;2-O
    • (2002) Electroanalysis , vol.14 , pp. 526-531
    • Ganjali, M.R.1    Hosseini, S.M.2    Salavati-Niasari, M.3    Poursaberi, T.4    Shamsipur, M.5    Javanbakht, M.6
  • 27
    • 0034525669 scopus 로고    scopus 로고
    • Nickel(II) ion selective electrode based on 2,5-thiophenylbis(5-tert- butyl-1,3-benzooxazole)
    • MR Ganjali SM Hosseini M Javanbakht OR Hashemi 2000 Nickel(II) ion selective electrode based on 2,5-thiophenylbis(5-tert-butyl-1,3-benzooxazole) Anal. Lett. 33 3139 3159
    • (2000) Anal. Lett. , vol.33 , pp. 3139-3159
    • Ganjali, M.R.1    Hosseini, S.M.2    Javanbakht, M.3    Hashemi, O.R.4
  • 28
    • 27144436168 scopus 로고    scopus 로고
    • Ni(II)-selective ion sensors of salen type Schiff base chelates
    • 10.1016/j.aca.2005.08.016
    • AK Jain VK Gupta PA Ganeshpure JR Raisoni 2005 Ni(II)-selective ion sensors of salen type Schiff base chelates Anal. Chim. Acta 553 177 184 10.1016/j.aca.2005.08.016
    • (2005) Anal. Chim. Acta , vol.553 , pp. 177-184
    • Jain, A.K.1    Gupta, V.K.2    Ganeshpure, P.A.3    Raisoni, J.R.4
  • 29
    • 13144259678 scopus 로고    scopus 로고
    • Nickel ion-selective PVC membrane electrode based on a new t-octyl-calix[6]arene derivative
    • 10.1007/s00604-004-0292-5
    • K Belhamel R Ludwig M Benamore 2005 Nickel ion-selective PVC membrane electrode based on a new t-octyl-calix[6]arene derivative Mikrochim. Acta 149 145 150 10.1007/s00604-004-0292-5
    • (2005) Mikrochim. Acta , vol.149 , pp. 145-150
    • Belhamel, K.1    Ludwig, R.2    Benamore, M.3
  • 30
    • 0033707401 scopus 로고    scopus 로고
    • New PVC-based 1,10-dibenzyl-1,10-diaza-16-crown-6-selective electrode for detecting nickel (II) ion
    • 10.1016/S0925-4005(99)00473-6
    • MF Mousavi N Alizadeh M Shamsipur N Zohari 2000 New PVC-based 1,10-dibenzyl-1,10-diaza-16-crown-6-selective electrode for detecting nickel (II) ion Sens. Actuators B Chem. 66 98 100 10.1016/S0925-4005(99)00473-6
    • (2000) Sens. Actuators B Chem. , vol.66 , pp. 98-100
    • Mousavi, M.F.1    Alizadeh, N.2    Shamsipur, M.3    Zohari, N.4
  • 31
    • 0034524406 scopus 로고    scopus 로고
    • A PVC based dibenzo-diaza-15-crown-4-membrane potentiometric sensor for Ni(II)
    • doi :10.1002/1521-4109(200012)12:18〈1472::AID-ELAN1472〉3.0. CO;2-0
    • Shamsipur, M., Kazemi, S.Y.: A PVC based dibenzo-diaza-15-crown-4- membrane potentiometric sensor for Ni(II). Electroanalysis 12, 1472-1475 (2000). doi :10.1002/1521-4109(200012)12:18〈1472::AID-ELAN1472〉3.0.CO;2-0
    • (2000) Electroanalysis , vol.12 , pp. 1472-1475
    • Shamsipur, M.1    Kazemi, S.Y.2
  • 32
    • 0001027423 scopus 로고
    • Response of poly(vinyl chloride) electrode based on neutral carrier 1,4,7,10-tetraoxacyclododecane-12-crown-4
    • 10.1016/S0003-2670(00)84770-4
    • MD Hampton CA Peters LA Wellington 1987 Response of poly(vinyl chloride) electrode based on neutral carrier 1,4,7,10-tetraoxacyclododecane-12-crown-4 Anal. Chim. Acta 194 171 176 10.1016/S0003-2670(00)84770-4
    • (1987) Anal. Chim. Acta , vol.194 , pp. 171-176
    • Hampton, M.D.1    Peters, C.A.2    Wellington, L.A.3
  • 33
    • 0030272516 scopus 로고    scopus 로고
    • Chelating ion exchange resin membrane sensor for nickel(II) ions
    • 10.1016/0039-9140(96)01959-5
    • GN Rao S Srivastava SK Srivastava M Singh 1996 Chelating ion exchange resin membrane sensor for nickel(II) ions Talanta 43 1821 1825 10.1016/0039-9140(96)01959-5
    • (1996) Talanta , vol.43 , pp. 1821-1825
    • Rao, G.N.1    Srivastava, S.2    Srivastava, S.K.3    Singh, M.4
  • 34
    • 0042522992 scopus 로고
    • Liquid membrane electrode for determination of nickel
    • C Luca M Pleniceanu N Muresan 1976 Liquid membrane electrode for determination of nickel Rev. Chim 27 1088 1090
    • (1976) Rev. Chim , vol.27 , pp. 1088-1090
    • Luca, C.1    Pleniceanu, M.2    Muresan, N.3
  • 35
    • 0001573287 scopus 로고
    • Study of metal chelates involving sulphur-containing ligands as active components of liquid membranes of ion-selective electrodes
    • EA Smirnova OM Petrukhin SL Rogatinskaya 1982 Study of metal chelates involving sulphur-containing ligands as active components of liquid membranes of ion-selective electrodes Zh. Anal. Khim 37 2137 2142
    • (1982) Zh. Anal. Khim , vol.37 , pp. 2137-2142
    • Smirnova, E.A.1    Petrukhin, O.M.2    Rogatinskaya, S.L.3
  • 36
    • 33847804944 scopus 로고
    • PVC matrix membrane ion-selective electrodes. Construction and laboratory experiments
    • A Craggs GJ Moody JDR Thomas 1974 PVC matrix membrane ion-selective electrodes. Construction and laboratory experiments J. Chem. Educ. 51 541 544
    • (1974) J. Chem. Educ. , vol.51 , pp. 541-544
    • Craggs, A.1    Moody, G.J.2    Thomas, J.D.R.3
  • 37
    • 0038690518 scopus 로고    scopus 로고
    • Thallium(I)-selective membrane potentiometric sensor based on dibenzyldiaza-18-crown-6
    • G Khayatian S Shariati A Salimi 2003 Thallium(I)-selective membrane potentiometric sensor based on dibenzyldiaza-18-crown-6 Bull. Korean Chem. Soc. 24 421 425
    • (2003) Bull. Korean Chem. Soc. , vol.24 , pp. 421-425
    • Khayatian, G.1    Shariati, S.2    Salimi, A.3
  • 38
    • 0037058635 scopus 로고    scopus 로고
    • Thallium(I)-selective membrane electrodes based on calix[6]arene or calix[5]arene derivatives
    • 10.1016/S0925-4005(02)00264-2
    • T Katsu K Ido K Takaishi H Yokosu 2002 Thallium(I)-selective membrane electrodes based on calix[6]arene or calix[5]arene derivatives Sens. Actuators B Chem. 87 331 335 10.1016/S0925-4005(02)00264-2
    • (2002) Sens. Actuators B Chem. , vol.87 , pp. 331-335
    • Katsu, T.1    Ido, K.2    Takaishi, K.3    Yokosu, H.4
  • 39
    • 0842287417 scopus 로고    scopus 로고
    • Tetrathiaoxamacrocycles with dibenzo-subunits: A search for new Tl(I) and Ag(I) selective ionophore
    • 10.1080/10610270310001597737
    • KM Park YH Lee Y Jin J Seo I Yoon SC Lee 2004 Tetrathiaoxamacrocycles with dibenzo-subunits: a search for new Tl(I) and Ag(I) selective ionophore Supramol. Chem. 16 51 58 10.1080/10610270310001597737
    • (2004) Supramol. Chem. , vol.16 , pp. 51-58
    • Park, K.M.1    Lee, Y.H.2    Jin, Y.3    Seo, J.4    Yoon, I.5    Lee, S.C.6
  • 40
    • 0000597406 scopus 로고    scopus 로고
    • Potentiometric ion-selective sensors
    • doi :10.1002/(SICI)1521-4109(199910)11:14〈1035::AID-ELAN1035〉3. 0.CO;2-I
    • Antonisse, M.M.G., Reinhoudt, D.N.: Potentiometric ion-selective sensors. Electroanalysis 11, 1035-1048 (1999). doi :10.1002/(SICI)1521-4109(199910)11: 14〈1035::AID-ELAN1035〉3.0.CO;2-I
    • (1999) Electroanalysis , vol.11 , pp. 1035-1048
    • Antonisse, M.M.G.1    Reinhoudt, D.N.2
  • 42
    • 0034339825 scopus 로고    scopus 로고
    • Iodide ion-selective PVC membrane electrode based on a recently synthesized salen Mn(II) complex
    • M Shamsipur S Sadeghi H Naeimi H Sharghi 2000 Iodide ion-selective PVC membrane electrode based on a recently synthesized salen Mn(II) complex Pol. J. Chem. 74 231 238
    • (2000) Pol. J. Chem. , vol.74 , pp. 231-238
    • Shamsipur, M.1    Sadeghi, S.2    Naeimi, H.3    Sharghi, H.4
  • 43
    • 0024106504 scopus 로고
    • Copper(II)-selective electrode using thiuram disulfide neutral carriers
    • 10.1021/ac00173a006
    • S Kamata A Bhale Y Fukunga A Nurata 1988 Copper(II)-selective electrode using thiuram disulfide neutral carriers Anal. Chem. 60 2464 2467 10.1021/ac00173a006
    • (1988) Anal. Chem. , vol.60 , pp. 2464-2467
    • Kamata, S.1    Bhale, A.2    Fukunga, Y.3    Nurata, A.4
  • 44
    • 4544366331 scopus 로고    scopus 로고
    • Carrier based ion-selective electrodes and bulk optodes. 1. General characteristics
    • 10.1021/cr940394a
    • E Bakker P Buhlmann E Pretsch 1997 Carrier based ion-selective electrodes and bulk optodes. 1. General characteristics Chem. Rev. 97 3083 3132 10.1021/cr940394a
    • (1997) Chem. Rev. , vol.97 , pp. 3083-3132
    • Bakker, E.1    Buhlmann, P.2    Pretsch, E.3
  • 45
    • 84956088296 scopus 로고
    • Commission on analytical nomenclature, recommendations for nomenclature for ion-selective electrodes
    • Analytical Chemistry Division, I.U.P.A.C. 10.1351/pac197648010127
    • Analytical Chemistry Division, I.U.P.A.C 1976 Commission on analytical nomenclature, recommendations for nomenclature for ion-selective electrodes Pure Appl. Chem. 48 127 131 10.1351/pac197648010127
    • (1976) Pure Appl. Chem. , vol.48 , pp. 127-131
  • 46
    • 84876596105 scopus 로고
    • Selectivity coefficients for ion-selective electrode. Recommended methods for reporting values
    • 10.1351/pac199567030507
    • Y Umezawa K Umezawa H Sato 1995 Selectivity coefficients for ion-selective electrode. Recommended methods for reporting values Pure Appl. Chem. 67 507 518 10.1351/pac199567030507
    • (1995) Pure Appl. Chem. , vol.67 , pp. 507-518
    • Umezawa, Y.1    Umezawa, K.2    Sato, H.3
  • 47
    • 0002232006 scopus 로고    scopus 로고
    • Selectivity of liquid membrane ion-selective electrodes
    • 10.1002/elan.1140090103
    • E Bakker 1997 Selectivity of liquid membrane ion-selective electrodes Electroanalysis 9 7 12 10.1002/elan.1140090103
    • (1997) Electroanalysis , vol.9 , pp. 7-12
    • Bakker, E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.