메뉴 건너뛰기




Volumn 401, Issue 1-2, 2009, Pages 63-67

Hydroxocobalamin and cyanocobalamin interference on co-oximetry based hemoglobin measurements

Author keywords

ABL 735; Co oximetry; Cyanide poisoning; Cyanocobalamin; GEM Premier 4000; Hydroxocobalamin; IL 682; Rapidpoint 405

Indexed keywords

CYANOCOBALAMIN; HEMOGLOBIN; HEMOGLOBIN DERIVATIVE; HYDROXOCOBALAMIN;

EID: 58549108766     PISSN: 00098981     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cca.2008.11.007     Document Type: Article
Times cited : (40)

References (10)
  • 1
    • 0035011333 scopus 로고    scopus 로고
    • Hydroxocobalamin: improved public health readiness for cyanide disasters
    • Sauer S.W., and Keim M.E. Hydroxocobalamin: improved public health readiness for cyanide disasters. Ann Emerg Med 37 (2001) 635-641
    • (2001) Ann Emerg Med , vol.37 , pp. 635-641
    • Sauer, S.W.1    Keim, M.E.2
  • 2
    • 34248583155 scopus 로고    scopus 로고
    • Prospective study of hydroxocobalamin for acute cyanide poisoning in smoke inhalation
    • Borron S.W., Baud F.J., Barriot P., Imbert M., and Bismuth C. Prospective study of hydroxocobalamin for acute cyanide poisoning in smoke inhalation. Ann Emerg Med 49 (2007) 794-801
    • (2007) Ann Emerg Med , vol.49 , pp. 794-801
    • Borron, S.W.1    Baud, F.J.2    Barriot, P.3    Imbert, M.4    Bismuth, C.5
  • 3
    • 0027253666 scopus 로고
    • Hydroxocobalamin as a cyanide antidote: safety, efficacy and pharmacokinetics in heavily smoking normal volunteers
    • Forsyth J.C., Mueller P.D., Baker C.E., Osterloh J., Benowitz N.L., Rumack B.H., et al. Hydroxocobalamin as a cyanide antidote: safety, efficacy and pharmacokinetics in heavily smoking normal volunteers. Clin Toxicol 31 (1993) 277-294
    • (1993) Clin Toxicol , vol.31 , pp. 277-294
    • Forsyth, J.C.1    Mueller, P.D.2    Baker, C.E.3    Osterloh, J.4    Benowitz, N.L.5    Rumack, B.H.6
  • 4
    • 34249039552 scopus 로고    scopus 로고
    • Is hydroxocobalamin safe and effective for smoke inhalation? Searching for guidance in the haze
    • Erdman A.R. Is hydroxocobalamin safe and effective for smoke inhalation? Searching for guidance in the haze. Ann Emerg Med 49 (2007) 814-816
    • (2007) Ann Emerg Med , vol.49 , pp. 814-816
    • Erdman, A.R.1
  • 5
    • 34249040210 scopus 로고    scopus 로고
    • Sodium thiosulfate or hydroxocobalamin for the empiric treatment of cyanide poisoning
    • Hall A.H., Dart R., and Bogdan G. Sodium thiosulfate or hydroxocobalamin for the empiric treatment of cyanide poisoning. Ann Emerg Med 49 (2007) 806-813
    • (2007) Ann Emerg Med , vol.49 , pp. 806-813
    • Hall, A.H.1    Dart, R.2    Bogdan, G.3
  • 6
    • 33646546316 scopus 로고    scopus 로고
    • Hydroxocobalamin as cyanide antidote
    • DesLauriers C.A., Burda A.M., and Wahl M. Hydroxocobalamin as cyanide antidote. Am J Ther 13 (2006) 161-165
    • (2006) Am J Ther , vol.13 , pp. 161-165
    • DesLauriers, C.A.1    Burda, A.M.2    Wahl, M.3
  • 7
    • 0028300007 scopus 로고
    • Determination of hydroxocobalamin and cyanocobalamin by derivative spectrophotometry in cyanide poisoning
    • Houeto P., Buneaux F., Galliot-Guilley M., Baud F.J., and Levillain P. Determination of hydroxocobalamin and cyanocobalamin by derivative spectrophotometry in cyanide poisoning. J Anal Toxicol 18 (1994) 154-158
    • (1994) J Anal Toxicol , vol.18 , pp. 154-158
    • Houeto, P.1    Buneaux, F.2    Galliot-Guilley, M.3    Baud, F.J.4    Levillain, P.5
  • 8
    • 34248529996 scopus 로고    scopus 로고
    • Potential interference by hydroxocobalamin on co-oximetry based hemoglobin measurements during cyanide and smoke inhalation treatments
    • Lee J., Mukal D., Kreuter K., Mahan S., Tromberg B., and Brenner M. Potential interference by hydroxocobalamin on co-oximetry based hemoglobin measurements during cyanide and smoke inhalation treatments. Ann Emerg Med 49 (2007) 802-805
    • (2007) Ann Emerg Med , vol.49 , pp. 802-805
    • Lee, J.1    Mukal, D.2    Kreuter, K.3    Mahan, S.4    Tromberg, B.5    Brenner, M.6
  • 9
    • 43349107447 scopus 로고    scopus 로고
    • Evaluation of GEM Premier 4000: a compact blood gas co-oximeter and electrolyte analyzer for point-of-care and laboratory testing
    • Burnat B.B., Pernet P., Pilon P., Latour D., Goujon S., Feuillu A., et al. Evaluation of GEM Premier 4000: a compact blood gas co-oximeter and electrolyte analyzer for point-of-care and laboratory testing. Clin Chem Lab Med 46 (2008) 271-279
    • (2008) Clin Chem Lab Med , vol.46 , pp. 271-279
    • Burnat, B.B.1    Pernet, P.2    Pilon, P.3    Latour, D.4    Goujon, S.5    Feuillu, A.6
  • 10
    • 46249122385 scopus 로고    scopus 로고
    • Spectrophotometry of hydroxocobalamin and hemoglobin reveals production of an unanticipated methemoglobin variant
    • Denninghoff K., Walter F.G., Langa A.J., He Y., and Chipman R.A. Spectrophotometry of hydroxocobalamin and hemoglobin reveals production of an unanticipated methemoglobin variant. Clin Toxicol 46 (2008) 545-550
    • (2008) Clin Toxicol , vol.46 , pp. 545-550
    • Denninghoff, K.1    Walter, F.G.2    Langa, A.J.3    He, Y.4    Chipman, R.A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.