Philips QT interval measurement algorithms for diagnostic, ambulatory, and patient monitoring ECG applications

Author keywords

Ambulatory ECG; In hospital QT monitoring; QT interval; QT measurement algorithm; Resting ECG

Indexed keywords

ALGORITHM; AMBULATORY MONITORING; ARTICLE; DATA BASE; DIAGNOSTIC ACCURACY; DIAGNOSTIC PROCEDURE; ELECTROCARDIOGRAPHY; GOLD STANDARD; HOLTER MONITORING; HUMAN; MEASUREMENT; PATIENT MONITORING; PERFORMANCE; PRIORITY JOURNAL; QT INTERVAL; RELIABILITY; T WAVE;

EID: 58449131891     PISSN: 1082720X     EISSN: 1542474X     Source Type: Journal    
DOI: 10.1111/j.1542-474X.2008.00258.x     Document Type: Article
Times cited : (44)

References (12)
  • 1
    • 33749076442 scopus 로고    scopus 로고
    • Global QT measurements in the Philips 12-lead Algorithm
    • Lindauer J, Gregg R, Helfenbein E, et al. Global QT measurements in the Philips 12-lead Algorithm. J Electrocard 2005 38 (Suppl. 90.
    • (2005) J Electrocard , vol.38 , pp. 90
    • Lindauer, J.1    Gregg, R.2    Helfenbein, E.3
  • 2
    • 33749064588 scopus 로고    scopus 로고
    • QT measurement performance in a Holter application
    • Feild DQ. QT measurement performance in a Holter application. J Electrocardiol 2005 38 (Suppl. 34.
    • (2005) J Electrocardiol , vol.38 , pp. 34
    • Feild, D.Q.1
  • 3
    • 33749078740 scopus 로고    scopus 로고
    • An algorithm for continuous real-time QT interval monitoring
    • Helfenbein E, Zhou S, Lindauer J, et al. An algorithm for continuous real-time QT interval monitoring. J Electrocardiol 2006 39 (4S 123 127.
    • (2006) J Electrocardiol , vol.39 , pp. 123-127
    • Helfenbein, E.1    Zhou, S.2    Lindauer, J.3
  • 4
    • 0028272466 scopus 로고
    • Errors in manual measurement of QT intervals
    • Murray A, McLaughlin NB, Bourke JP, et al. Errors in manual measurement of QT intervals. Br Heart J 1994 71 : 386 390.
    • (1994) Br Heart J , vol.71 , pp. 386-390
    • Murray, A.1    McLaughlin, N.B.2    Bourke, J.P.3
  • 5
    • 33745151940 scopus 로고    scopus 로고
    • Relationship of QT interval measurements to evolving automated algorithm from different manufacturers of elctrocardiographs
    • Kligfield P, Hancock EW, Helfenbein ED, et al. Relationship of QT interval measurements to evolving automated algorithm from different manufacturers of elctrocardiographs. Am J Cardiol 2006 98 : 88 92.
    • (2006) Am J Cardiol , vol.98 , pp. 88-92
    • Kligfield, P.1    Hancock, E.W.2    Helfenbein, E.D.3
  • 6
    • 58449133035 scopus 로고    scopus 로고
    • Automated QT measurements for moxifloxicin and physiologic challenge in health volunteers
    • Lindauer JM, Agin M, Stock T. Automated QT measurements for moxifloxicin and physiologic challenge in health volunteers. J Electrocardiol 2007 40 (Suppl S32.
    • (2007) J Electrocardiol , vol.40
    • Lindauer, J.M.1    Agin, M.2    Stock, T.3
  • 7
    • 0026786140 scopus 로고
    • Sex differences in the evolution of the electrocardiographic QT interval with age
    • Rautaharju P, Zhou S, Wong S, et al. Sex differences in the evolution of the electrocardiographic QT interval with age. Can J Cardiol 1992 8 : 690 695.
    • (1992) Can J Cardiol , vol.8 , pp. 690-695
    • Rautaharju, P.1    Zhou, S.2    Wong, S.3
  • 8
    • 10744223189 scopus 로고    scopus 로고
    • Electrocardiographic identification of drug-induced QT prolongation: Assessment by different recording and measurement methods
    • Sarapa N, Morganroth J, Couderc JP, et al. Electrocardiographic identification of drug-induced QT prolongation: Assessment by different recording and measurement methods. Ann Noninvasive Electrocardiol 2004 9 : 48 57.
    • (2004) Ann Noninvasive Electrocardiol , vol.9 , pp. 48-57
    • Sarapa, N.1    Morganroth, J.2    Couderc, J.P.3
  • 9
    • 0031355513 scopus 로고    scopus 로고
    • Evaluation of an automatic threshold based detector of waveform limits in Holter ECG with the QT database
    • Jane R, Blasi A, Garcia J, et al. Evaluation of an automatic threshold based detector of waveform limits in Holter ECG with the QT database. IEEE Comput Cardiol 1997 24 : 295 298.
    • (1997) IEEE Comput Cardiol , vol.24 , pp. 295-298
    • Jane, R.1    Blasi, A.2    Garcia, J.3
  • 10
    • 30344470225 scopus 로고    scopus 로고
    • QTc prolongation and sudden cardiac death
    • Moss A. QTc prolongation and sudden cardiac death. J Am Coll Cardiol 2006 47 : 368 369.
    • (2006) J Am Coll Cardiol , vol.47 , pp. 368-369
    • Moss, A.1
  • 11
    • 35748935841 scopus 로고    scopus 로고
    • An algorithm for QT interval monitoring in neonatal intensive-care units
    • Helfenbein ED, Ackerman M, Rautaharju PM, et al. An algorithm for QT interval monitoring in neonatal intensive-care units. J Electrocardiol 2007 40 (Supp S103 S110.
    • (2007) J Electrocardiol , vol.40
    • Helfenbein, E.D.1    Ackerman, M.2    Rautaharju, P.M.3
  • 12
    • 58449137381 scopus 로고    scopus 로고
    • Comparison of two automated methods for QT interval measurements
    • Gregg RE, Feild DQ, Helfenbein ED, et al. Comparison of two automated methods for QT interval measurements. IEEE ComputCardiol 2007 34 : 427 430.
    • (2007) IEEE ComputCardiol , vol.34 , pp. 427-430
    • Gregg, R.E.1    Feild, D.Q.2    Helfenbein, E.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.