메뉴 건너뛰기




Volumn 18, Issue 2, 2008, Pages 108-113

Reamer Irrigator Aspirator: A New Technique for Bone Graft Harvesting from the Intramedullary Canal

Author keywords

autologous grafting; bone graft; femoral canal reaming; reaming of the femur

Indexed keywords

ARTICLE; BONE GRAFT; BONE TRANSPLANTATION; CANCELLOUS BONE; FEMUR; FLUOROSCOPY; GUIDE WIRE; HUMAN; MEDICAL ASSESSMENT; ORTHOPEDIC EQUIPMENT; POSTOPERATIVE COMPLICATION; POSTOPERATIVE HEMORRHAGE; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; REAMER IRRIGATOR ASPIRATOR; SURGICAL APPROACH; SURGICAL TECHNIQUE; TIBIA; TREATMENT INDICATION;

EID: 58449114107     PISSN: 10486666     EISSN: None     Source Type: Journal    
DOI: 10.1053/j.oto.2008.08.001     Document Type: Article
Times cited : (18)

References (11)
  • 1
    • 44949164427 scopus 로고    scopus 로고
    • Use of the 'reamer irrigator aspirator' system for non-infected tibial non-union after failed iliac crest grafting
    • Kobbe P., Tarkin I.S., and Pape H.C. Use of the 'reamer irrigator aspirator' system for non-infected tibial non-union after failed iliac crest grafting. Injury 39 (2008) 796-800
    • (2008) Injury , vol.39 , pp. 796-800
    • Kobbe, P.1    Tarkin, I.S.2    Pape, H.C.3
  • 2
    • 46649093378 scopus 로고    scopus 로고
    • Voluminous bone graft harvesting of the femoral marrow cavity for autologous transplantation: An indication for the "Reamer-Irrigator-Aspirator-" (RIA-) technique [in German]
    • Kobbe P., Tarkin I.S., Frink M., et al. Voluminous bone graft harvesting of the femoral marrow cavity for autologous transplantation: An indication for the "Reamer-Irrigator-Aspirator-" (RIA-) technique [in German]. Unfallchirurg 111 (2008) 469-472
    • (2008) Unfallchirurg , vol.111 , pp. 469-472
    • Kobbe, P.1    Tarkin, I.S.2    Frink, M.3
  • 3
    • 42149154468 scopus 로고    scopus 로고
    • A new minimally invasive technique for large volume bone graft harvest for treatment of fracture nonunions
    • Newman J.T., Stahel P.F., Smith W.R., et al. A new minimally invasive technique for large volume bone graft harvest for treatment of fracture nonunions. Orthopedics 31 (2008) 257-261
    • (2008) Orthopedics , vol.31 , pp. 257-261
    • Newman, J.T.1    Stahel, P.F.2    Smith, W.R.3
  • 4
    • 34247604063 scopus 로고    scopus 로고
    • Quantification of various growth factors in different demineralized bone matrix preparations
    • Wildemann B., Kadow-Romacker A., Haas N.P., et al. Quantification of various growth factors in different demineralized bone matrix preparations. J Biomed Mater Res A 81 (2007) 437-442
    • (2007) J Biomed Mater Res A , vol.81 , pp. 437-442
    • Wildemann, B.1    Kadow-Romacker, A.2    Haas, N.P.3
  • 5
    • 0033995610 scopus 로고    scopus 로고
    • Pressure changes during reaming with different parameters and reamer designs
    • Mousavi M., David R., Ehteshami J., et al. Pressure changes during reaming with different parameters and reamer designs. Clin Orthop Rel Res 373 (2000) 295-303
    • (2000) Clin Orthop Rel Res , vol.373 , pp. 295-303
    • Mousavi, M.1    David, R.2    Ehteshami, J.3
  • 6
    • 33751059579 scopus 로고    scopus 로고
    • Femoral nailing through the trochanter: The reamer pathway indicates a helical nail shape
    • Ehmke L.W., Polzin B.M., Madey S.M., et al. Femoral nailing through the trochanter: The reamer pathway indicates a helical nail shape. J Orthop Trauma 20 (2006) 668-674
    • (2006) J Orthop Trauma , vol.20 , pp. 668-674
    • Ehmke, L.W.1    Polzin, B.M.2    Madey, S.M.3
  • 7
    • 0033773938 scopus 로고    scopus 로고
    • When one liter does not equal 1000 milliliters: Implications for the tumescent technique
    • Coleman W.P. When one liter does not equal 1000 milliliters: Implications for the tumescent technique. Dermatol Surg 26 (2000) 1024-1028
    • (2000) Dermatol Surg , vol.26 , pp. 1024-1028
    • Coleman, W.P.1
  • 8
    • 0031963392 scopus 로고    scopus 로고
    • Mechanical effects of different localization of the point of entry in femoral nailing
    • Strand R.M., Mølster A.O., Engesaeter L.B., et al. Mechanical effects of different localization of the point of entry in femoral nailing. Arch Orthop Trauma Surg 117 (1998) 35-38
    • (1998) Arch Orthop Trauma Surg , vol.117 , pp. 35-38
    • Strand, R.M.1    Mølster, A.O.2    Engesaeter, L.B.3
  • 10
    • 34247630045 scopus 로고    scopus 로고
    • Cortical heat generation using an irrigating/aspirating single-pass reaming vs conventional stepwise reaming
    • Higgins T.F., Casey V., and Bachus K. Cortical heat generation using an irrigating/aspirating single-pass reaming vs conventional stepwise reaming. J Orthop Trauma 21 (2007) 192-197
    • (2007) J Orthop Trauma , vol.21 , pp. 192-197
    • Higgins, T.F.1    Casey, V.2    Bachus, K.3
  • 11
    • 33749626666 scopus 로고    scopus 로고
    • Quantitative assessment of growth factors in reaming aspirate, iliac crest, and platelet preparation
    • Schmidmaier G., Herrmann S., Green J., et al. Quantitative assessment of growth factors in reaming aspirate, iliac crest, and platelet preparation. Bone 39 (2006) 1156-1163
    • (2006) Bone , vol.39 , pp. 1156-1163
    • Schmidmaier, G.1    Herrmann, S.2    Green, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.