Prevalence of interfering substances with point-of-care glucose testing in a community hospital

Author keywords

Dextrose; Hospitals; Tests, laboratory

Indexed keywords

BILIRUBIN; GLUCOSE; GLUCOSE DEHYDROGENASE; INSULIN; PARACETAMOL; PYRROLOQUINOLINEQUINONE; TRIACYLGLYCEROL; URIC ACID;

EID: 58449090580     PISSN: 10792082     EISSN: None     Source Type: Journal    
DOI: 10.2146/ajhp070512     Document Type: Article
Times cited : (15)

References (23)
  • 1
    • 0033843815 scopus 로고    scopus 로고
    • Potential for error from underfilling Glucometer Elite test strips
    • Wiener K. Potential for error from underfilling Glucometer Elite test strips. Diabet Med. 2000; 17:555-6.
    • (2000) Diabet Med , vol.17 , pp. 555-556
    • Wiener, K.1
  • 2
    • 0035036665 scopus 로고    scopus 로고
    • Process improvement for bedside capillary glucose testing in a large academic medical center: The impact of new technology on point-of-care testing
    • Lewandrowski E, Mac Millan D, Misiano D et al. Process improvement for bedside capillary glucose testing in a large academic medical center: the impact of new technology on point-of-care testing. Clin Chim Acta. 2001; 307:175-9.
    • (2001) Clin Chim Acta , vol.307 , pp. 175-179
    • Lewandrowski, E.1    Mac Millan, D.2    Misiano, D.3
  • 3
    • 33644847768 scopus 로고    scopus 로고
    • Effect of adverse storage conditions on performance of glucometer test strips
    • Bamberg R, Schulman K, MacKenzie M et al. Effect of adverse storage conditions on performance of glucometer test strips. Clin Lab Sci. 2005; 18:203-9.
    • (2005) Clin Lab Sci , vol.18 , pp. 203-209
    • Bamberg, R.1    Schulman, K.2    MacKenzie, M.3
  • 5
    • 84888549026 scopus 로고    scopus 로고
    • In vitro diagnostic test systems, requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus. ISO 15197:2003E, Geneva, Switzerland: International Organization for Standardization
    • In vitro diagnostic test systems - requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus. ISO 15197:2003(E). Geneva, Switzerland: International Organization for Standardization.
  • 6
    • 84888477311 scopus 로고    scopus 로고
    • ACCU-CHEK Comfort Curve test strips package insert. Indianapolis, IN: Roche Diagnostics; 2007
    • ACCU-CHEK Comfort Curve test strips package insert. Indianapolis, IN: Roche Diagnostics; 2007.
  • 7
    • 33846947575 scopus 로고    scopus 로고
    • Icodextrin: A major problem for glucose dehydrogenase-based glucose point of care testing systems
    • In Dutch
    • Floré K, Delanghe J. Icodextrin: a major problem for glucose dehydrogenase-based glucose point of care testing systems. Acta Clin Belg. 2006; 61:351-4. In Dutch.
    • (2006) Acta Clin Belg , vol.61 , pp. 351-354
    • Floré, K.1    Delanghe, J.2
  • 8
    • 84888553720 scopus 로고    scopus 로고
    • EXTRANEAL package insert. Deerfield, IL: Baxter Healthcare Corporation; 2008 Jun
    • EXTRANEAL package insert. Deerfield, IL: Baxter Healthcare Corporation; 2008 Jun.
  • 9
    • 84888565618 scopus 로고    scopus 로고
    • accessed 2008 Oct 30
    • College of American Pathologists. Bedside glucose testing systems. www.cap.org/apps/docs/cap-today/surveys/0408-Glucose-Survey.pdf (accessed 2008 Oct 30).
    • Bedside glucose testing systems
  • 10
    • 84888527274 scopus 로고    scopus 로고
    • Precision PCx Plus test strips package insert. Bedford, MA: Abbott Laboratories, Medisense Products; 2003 Jan
    • Precision PCx Plus test strips package insert. Bedford, MA: Abbott Laboratories, Medisense Products; 2003 Jan.
  • 11
    • 84888562180 scopus 로고    scopus 로고
    • SureStep Pro test strips package insert. Milpitas, CA: LifeScan; 2004 Jan
    • SureStep Pro test strips package insert. Milpitas, CA: LifeScan; 2004 Jan.
  • 12
    • 84888480793 scopus 로고    scopus 로고
    • StatStrip test strips package insert. Waltham, MA: Nova Biomedical; 2008 Mar
    • StatStrip test strips package insert. Waltham, MA: Nova Biomedical; 2008 Mar.
  • 13
    • 58449109547 scopus 로고    scopus 로고
    • Minimizing hypoglycemia attributed to an interaction between icodextrin peritoneal dialysis solution and blood glucose test strips: Utility of a U.S. postmarketing safety program
    • Paper presented at, Washington, DC; Apr 27
    • Southworth MR, Kortepeter C, Lu S. Minimizing hypoglycemia attributed to an interaction between icodextrin peritoneal dialysis solution and blood glucose test strips: utility of a U.S. postmarketing safety program. Paper presented at FDA Science Forum, Washington, DC; 2005 Apr 27.
    • (2005) FDA Science Forum
    • Southworth, M.R.1    Kortepeter, C.2    Lu, S.3
  • 14
    • 84888505208 scopus 로고    scopus 로고
    • Australian Government Department of Health and Ageing Therapeutic Goods Administration, Apr, medical device incident investigations, accessed 2008 Oct 30
    • Australian Government Department of Health and Ageing Therapeutic Goods Administration. TGA news issue 46 (Apr 2005) - medical device incident investigations. www.tga.gov.au/docs/html/tganews/news46/iris.htm (accessed 2008 Oct 30).
    • (2005) TGA news , Issue.46
  • 15
    • 84888507057 scopus 로고    scopus 로고
    • Medication safety alert
    • accessed 2008 Oct 30
    • Institute for Safe Medication Practices. Medication safety alert. Be aware of false glucose results with point-of-care testing. www.ismp.org/ newsletters/acutecare/articles/20050908.asp (accessed 2008 Oct 30).
    • Be aware of false glucose results with point-of-care testing
  • 16
    • 84888477180 scopus 로고    scopus 로고
    • Center for Biologics Evaluation and Research. Fatal iatrogenic hypoglycemia. Falsely elevated blood glucose readings with a point-of-care meter due to a maltose-containing intravenous immune globulin product, accessed 2008 Oct 30
    • Gaines AR, Pierce LR, Bernhardt PA. Food and Drug Administration. Center for Biologics Evaluation and Research. Fatal iatrogenic hypoglycemia. Falsely elevated blood glucose readings with a point-of-care meter due to a maltose-containing intravenous immune globulin product. www.fda.gov/cber/safety/ glucfalse.htm (accessed 2008 Oct 30).
    • Gaines, A.R.1    Pierce, L.R.2    Bernhardt, P.A.3
  • 17
    • 84888500307 scopus 로고    scopus 로고
    • Medical device alert
    • accessed 2008 Oct 30
    • Medicines and Healthcare Products Regulatory Agency. Medical device alert. Point-of-care and home-use blood glucose meters. www.mhra.gov.uk/ Publications/Safetywarnings/MedicalDeviceAlerts/CON2031807 (accessed 2008 Oct 30).
    • Point-of-care and home-use blood glucose meters
  • 18
    • 84888528218 scopus 로고    scopus 로고
    • Nov 4, 2005, accessed 2008 Oct 30
    • Food and Drug Administration. Blood Products Advisory Committee transcripts. Nov 4, 2005. www.fda.gov/ohrms/dockets/ac/03/briefing/4014b1-20- reprintsforabbreviatedhistory.pdf (accessed 2008 Oct 30).
    • Blood Products Advisory Committee transcripts
  • 19
    • 33846681947 scopus 로고    scopus 로고
    • Glucose measurement: Confounding issues in setting targets for inpatient management
    • Dungan K, Chapman J, Braithwaite SS et al. Glucose measurement: confounding issues in setting targets for inpatient management. Diabetes Care. 2007; 30:403-9.
    • (2007) Diabetes Care , vol.30 , pp. 403-409
    • Dungan, K.1    Chapman, J.2    Braithwaite, S.S.3
  • 20
    • 34548306928 scopus 로고    scopus 로고
    • Interference of maltose, icodextrin, galactose, or xylose with some blood glucose monitoring systems
    • Schleis TG. Interference of maltose, icodextrin, galactose, or xylose with some blood glucose monitoring systems. Pharmacotherapy. 2007; 27:1313-21.
    • (2007) Pharmacotherapy , vol.27 , pp. 1313-1321
    • Schleis, T.G.1
  • 21
    • 0033966742 scopus 로고    scopus 로고
    • Point-of-care glucose testing: Effects of critical care variables, influence of reference instruments, and a modular glucose meter design
    • Louie RF, Tang Z, Sutton DV et al. Point-of-care glucose testing: effects of critical care variables, influence of reference instruments, and a modular glucose meter design. Arch Pathol Lab Med. 2000; 124:257-66.
    • (2000) Arch Pathol Lab Med , vol.124 , pp. 257-266
    • Louie, R.F.1    Tang, Z.2    Sutton, D.V.3
  • 22
    • 0033848377 scopus 로고    scopus 로고
    • Evaluation of the Abbott PCx point of care glucose analyzer in a pediatric hospital
    • Soldin SJ, Devairakkam PD, Aagarwalla PK. Evaluation of the Abbott PCx point of care glucose analyzer in a pediatric hospital. Clin Biochem. 2000; 33:319-21.
    • (2000) Clin Biochem , vol.33 , pp. 319-321
    • Soldin, S.J.1    Devairakkam, P.D.2    Aagarwalla, P.K.3
  • 23
    • 0031949345 scopus 로고    scopus 로고
    • Toxic levels of acetaminophen produce a major positive interference on Glucometer Elite and Accu-chek Advantage glucose meters
    • Cartier LJ, Leclerc P, Pouliot M et al. Toxic levels of acetaminophen produce a major positive interference on Glucometer Elite and Accu-chek Advantage glucose meters. Clin Chem. 1998; 44:893-4.
    • (1998) Clin Chem , vol.44 , pp. 893-894
    • Cartier, L.J.1    Leclerc, P.2    Pouliot, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.