메뉴 건너뛰기




Volumn , Issue , 2006, Pages 507-512

Effect of cold spray deposition of a titanium coating on fatigue behavior of a titanium alloy

Author keywords

CGDS; Fatigue; Residual stress; Ti6A14V; Titanium; Young's modulus

Indexed keywords

ALLOYS; CERIUM ALLOYS; COATINGS; DURABILITY; ELASTIC MODULI; ELASTICITY; GAS DYNAMICS; PESTICIDES; RESIDUAL STRESSES; STRENGTH OF MATERIALS; SUBSTRATES; SURFACE TREATMENT; THERMAL SPRAYING; TITANIUM;

EID: 58349100477     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1361/105996306X147108     Document Type: Conference Paper
Times cited : (25)

References (24)
  • 1
    • 5644235476 scopus 로고    scopus 로고
    • Biomedical Coatings to Improve the Tissue-Biomaterial Interface
    • G. Rizzi, A. Scrivani, M. Fini, and R. Giardino, Biomedical Coatings to Improve the Tissue-Biomaterial Interface, Int. J. Artif. Organs, 2004, 27, p. 649-657
    • (2004) Int. J. Artif. Organs , vol.27 , pp. 649-657
    • Rizzi, G.1    Scrivani, A.2    Fini, M.3    Giardino, R.4
  • 2
    • 58349104284 scopus 로고    scopus 로고
    • D.M. Brunette, Principles of Cell Behavior on Titanium Surfaces and Their Application to Implanted Devices, D.M. Brunette, P. Tengvall, M. Textor, and P. Thomsen, Ed., Titanium in Medicine: Material Science, Surface Science, Engineering, Biological Responses and Medical Applications, Springer-Verlag, 2001, p. 485-512
    • D.M. Brunette, Principles of Cell Behavior on Titanium Surfaces and Their Application to Implanted Devices, D.M. Brunette, P. Tengvall, M. Textor, and P. Thomsen, Ed., Titanium in Medicine: Material Science, Surface Science, Engineering, Biological Responses and Medical Applications, Springer-Verlag, 2001, p. 485-512
  • 4
    • 8144220495 scopus 로고    scopus 로고
    • Current Concepts Review: Hydroxyapatite-Coated Prostheses in Total Hip and Knee Arthroplasty
    • J. Dumbleton and M.T. Manley, Current Concepts Review: Hydroxyapatite-Coated Prostheses in Total Hip and Knee Arthroplasty, J. Bone Joint Surg Am., 2004, 86A, p. 2526-2540
    • (2004) J. Bone Joint Surg Am , vol.86 A , pp. 2526-2540
    • Dumbleton, J.1    Manley, M.T.2
  • 5
    • 0028401595 scopus 로고
    • Bone Response to Hydroxyapatite-Coated and Commercially Pure Titanium Implants in the Human Arthritic Knee
    • L. Carlsson, L. Regner, C. Johansson, M. Gottlander, and P. Herberts, Bone Response to Hydroxyapatite-Coated and Commercially Pure Titanium Implants in the Human Arthritic Knee, J Orthop. Res., 1994, 12, p. 274-285
    • (1994) J Orthop. Res , vol.12 , pp. 274-285
    • Carlsson, L.1    Regner, L.2    Johansson, C.3    Gottlander, M.4    Herberts, P.5
  • 6
    • 0032820823 scopus 로고    scopus 로고
    • A Randomized Trial of Hydroxyapatite Coated Prostheses in Total Hip Arthroplasty
    • A.J.M. Yee, H.K. Kreder, I. Bookman, and J.R. Davey, A Randomized Trial of Hydroxyapatite Coated Prostheses in Total Hip Arthroplasty, Clin. Orthop., 1999, 366, p. 120-132
    • (1999) Clin. Orthop , vol.366 , pp. 120-132
    • Yee, A.J.M.1    Kreder, H.K.2    Bookman, I.3    Davey, J.R.4
  • 7
    • 0034807973 scopus 로고    scopus 로고
    • Hydroxyapatite-Coated versus Grit-Blasted Femoral Stems: A Prospective, Randomised Study Using EBRA-FCA
    • M. Hamadouche, J. Witvoet, R. Porcher, A. Meunier, L. Sedel, and R. Nizard, Hydroxyapatite-Coated versus Grit-Blasted Femoral Stems: A Prospective, Randomised Study Using EBRA-FCA, J. Bone Joint Surg. Br., 2001, 83B, p. 979-987
    • (2001) J. Bone Joint Surg. Br , vol.83 B , pp. 979-987
    • Hamadouche, M.1    Witvoet, J.2    Porcher, R.3    Meunier, A.4    Sedel, L.5    Nizard, R.6
  • 8
    • 0038682066 scopus 로고    scopus 로고
    • Biological Fixation of Hydroxyapatite-Coated versus Grit-Blasted Titanium Hip Stems: A Canine Study
    • A. Eckardt, H.M. Aberman, H.D. Cantwell, and J. Heine, Biological Fixation of Hydroxyapatite-Coated versus Grit-Blasted Titanium Hip Stems: A Canine Study, Arch. Orthop. Trauma Surg., 2003, 123, p. 28-35
    • (2003) Arch. Orthop. Trauma Surg , vol.123 , pp. 28-35
    • Eckardt, A.1    Aberman, H.M.2    Cantwell, H.D.3    Heine, J.4
  • 10
    • 0141855302 scopus 로고    scopus 로고
    • Comparison of Porous-Coated Titanium Femoral Stems with and without Hydroxyapatite Coating
    • Y.H. Kim, J.S. Kim, S.H. Oh, and J.M. Kim, Comparison of Porous-Coated Titanium Femoral Stems with and without Hydroxyapatite Coating, J. Bone Joint Surg. Am., 2003, 85A, p. 1682-1688
    • (2003) J. Bone Joint Surg. Am , vol.85 A , pp. 1682-1688
    • Kim, Y.H.1    Kim, J.S.2    Oh, S.H.3    Kim, J.M.4
  • 11
    • 0036908789 scopus 로고    scopus 로고
    • Relative Contributions of Chemistry and Topography to the Osseointegration of Hydroxyapatite Coatings
    • S.A. Hacking, M. Tanzer, E.J. Harvey, J.J. Krygier, and J.D. Bobyn, Relative Contributions of Chemistry and Topography to the Osseointegration of Hydroxyapatite Coatings, Clin. Orthop., 2002, 405, p. 24-38
    • (2002) Clin. Orthop , vol.405 , pp. 24-38
    • Hacking, S.A.1    Tanzer, M.2    Harvey, E.J.3    Krygier, J.J.4    Bobyn, J.D.5
  • 13
    • 0035906563 scopus 로고    scopus 로고
    • Hyperkinetic Deposition of Nanopowders by Supersonic Rectangular Jet Impingement
    • V. Shukla, G.S. Elliott, B.H. Kear, and L.E. McCandlish, Hyperkinetic Deposition of Nanopowders by Supersonic Rectangular Jet Impingement, Scr. Mater., 2001, 44, p. 2179-2182
    • (2001) Scr. Mater , vol.44 , pp. 2179-2182
    • Shukla, V.1    Elliott, G.S.2    Kear, B.H.3    McCandlish, L.E.4
  • 14
    • 0034017794 scopus 로고    scopus 로고
    • The Effect of Sandblasting Treatment on Endurance Properties of Titanium Alloy Hip Prostheses
    • M. Baleani, M. Viceconti, and A. Toni, The Effect of Sandblasting Treatment on Endurance Properties of Titanium Alloy Hip Prostheses, Artif. Organs, 2000, 24, p. 296-299
    • (2000) Artif. Organs , vol.24 , pp. 296-299
    • Baleani, M.1    Viceconti, M.2    Toni, A.3
  • 15
    • 0032592135 scopus 로고    scopus 로고
    • Validation of the Step Test Method for Generating Haigh Diagrams for Ti-6A1-4V
    • R.S. Bellows, S. Muju, and T. Nicholas, Validation of the Step Test Method for Generating Haigh Diagrams for Ti-6A1-4V, Int. J. Fatigue, 1999, 21, p. 687-697
    • (1999) Int. J. Fatigue , vol.21 , pp. 687-697
    • Bellows, R.S.1    Muju, S.2    Nicholas, T.3
  • 16
    • 0032632441 scopus 로고    scopus 로고
    • D.C. Maxwell and T. Nicholas, A Rapid Method for Generation of a Haigh Diagram for High Cycle Fatigue, ASTM STP 1332, Fatigue and Fracture Mechanics, 29, T.L. Panontin and S.D. Sheppard, Ed., ASM International 1999, p. 626-641
    • D.C. Maxwell and T. Nicholas, A Rapid Method for Generation of a Haigh Diagram for High Cycle Fatigue, ASTM STP 1332, Fatigue and Fracture Mechanics, Vol. 29, T.L. Panontin and S.D. Sheppard, Ed., ASM International 1999, p. 626-641
  • 17
    • 0035213227 scopus 로고    scopus 로고
    • Influence of Residual Stresses on High Cycle Fatigue Strength of Ti-6Al-4V Subjected to Foreign Object Damage
    • S.R. Thompson, J.J. Ruschau, and T. Nicholas, Influence of Residual Stresses on High Cycle Fatigue Strength of Ti-6Al-4V Subjected to Foreign Object Damage, Int. J. Fatigue, 2001, 23, p. S405-S412
    • (2001) Int. J. Fatigue , vol.23
    • Thompson, S.R.1    Ruschau, J.J.2    Nicholas, T.3
  • 18
    • 0036672701 scopus 로고    scopus 로고
    • Step Loading for Very High Cycle Fatigue
    • T. Nicholas, Step Loading for Very High Cycle Fatigue, Fatigue Fract. Eng Mater. Struct., 2002, 25, p. 861-869
    • (2002) Fatigue Fract. Eng Mater. Struct , vol.25 , pp. 861-869
    • Nicholas, T.1
  • 20
    • 0030408924 scopus 로고    scopus 로고
    • Residual Stresses in Thermal Spray Coatings and Their Effect on Interfacial Adhesion: A Review of Recent Work
    • T.W. Clyne and S.C. Gill, Residual Stresses in Thermal Spray Coatings and Their Effect on Interfacial Adhesion: A Review of Recent Work, J. Therm. Spray Technol., 1996, 5, p. 401-418
    • (1996) J. Therm. Spray Technol , vol.5 , pp. 401-418
    • Clyne, T.W.1    Gill, S.C.2
  • 22
    • 0036860884 scopus 로고    scopus 로고
    • Deposition Efficiency, Mechanical Properties and Coating Roughness in Cold-Sprayed Titanium
    • R.S. Lima, A. Kucuk, C.C. Berndt, J. Karthikeyan, CM. Kay, and J. Lindemann, Deposition Efficiency, Mechanical Properties and Coating Roughness in Cold-Sprayed Titanium, J. Mater. Sci. Lett., 2002, 21, p. 1687-1689
    • (2002) J. Mater. Sci. Lett , vol.21 , pp. 1687-1689
    • Lima, R.S.1    Kucuk, A.2    Berndt, C.C.3    Karthikeyan, J.4    Kay, C.M.5    Lindemann, J.6
  • 23
    • 0026154370 scopus 로고
    • The Quenching Stress in Thermally Sprayed Coatings
    • S. Kuroda and T.W. Clyne, The Quenching Stress in Thermally Sprayed Coatings, Thin Solid Films, 1991, 200, p. 49-66
    • (1991) Thin Solid Films , vol.200 , pp. 49-66
    • Kuroda, S.1    Clyne, T.W.2
  • 24
    • 0842334597 scopus 로고    scopus 로고
    • Role of Thermal Spray Processing Method on the Microstructure, Residual Stress and Properties of Coatings: An Integrated Study for Ni-5 wt.% Al Bond Coats
    • S. Sampath, X.Y. Jiang, J. Matejicek, L. Prchlik, A. Kulkarni, and A. Vaidya, Role of Thermal Spray Processing Method on the Microstructure, Residual Stress and Properties of Coatings: An Integrated Study for Ni-5 wt.% Al Bond Coats, Mater. Sci. Eng. A, 2004, 364, p. 216-231
    • (2004) Mater. Sci. Eng. A , vol.364 , pp. 216-231
    • Sampath, S.1    Jiang, X.Y.2    Matejicek, J.3    Prchlik, L.4    Kulkarni, A.5    Vaidya, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.