메뉴 건너뛰기




Volumn 30, Issue 1, 2009, Pages 46-52

High-resolution 3T MR angiography of the carotid arteries: Comparison of manual and semiautomated quantification of stenosis

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTERY DIAMETER; ARTICLE; AUTOMATION; CAROTID ARTERY OBSTRUCTION; CLINICAL ARTICLE; CONTRAST ENHANCEMENT; FEMALE; HUMAN; MAGNETIC RESONANCE ANGIOGRAPHY; MALE; QUANTITATIVE DIAGNOSIS;

EID: 58249124567     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: 10.3174/ajnr.A1302     Document Type: Article
Times cited : (7)

References (34)
  • 1
    • 0037830587 scopus 로고
    • For severe carotid stenosis found on ultrasound, further arterial evaluation prior to carotid endarterectomy is unnecessary: The argument against
    • discussion
    • Rothwell PM. For severe carotid stenosis found on ultrasound, further arterial evaluation prior to carotid endarterectomy is unnecessary: the argument against. Stroke 2003;34:1817-19, discussion 1819
    • (1819) Stroke 2003 , vol.34 , pp. 1817-1819
    • Rothwell, P.M.1
  • 2
    • 33646165521 scopus 로고    scopus 로고
    • Non-invasive imaging compared with intra-arterial angiography in the diagnosis of symptomatic carotid stenosis: A meta-analysis
    • Wardlaw JM, Chappell FM, Best JJ, et al. Non-invasive imaging compared with intra-arterial angiography in the diagnosis of symptomatic carotid stenosis: a meta-analysis. Lancet 2006;367:1503-12
    • (2006) Lancet , vol.367 , pp. 1503-1512
    • Wardlaw, J.M.1    Chappell, F.M.2    Best, J.J.3
  • 3
    • 33745964947 scopus 로고    scopus 로고
    • Effect of nonoptimal imaging on the relationship between the measured degree of symptomatic carotid stenosis and risk of ischemic stroke
    • Cuffe RL, Rothwell PM. Effect of nonoptimal imaging on the relationship between the measured degree of symptomatic carotid stenosis and risk of ischemic stroke. Stroke 2006;37:1785-91
    • (2006) Stroke , vol.37 , pp. 1785-1791
    • Cuffe, R.L.1    Rothwell, P.M.2
  • 4
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partially parallel acquisitions (GRAPPA)
    • Griswold MA, Jakob PM, Heidemann RM, et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002;47:1202-10
    • (2002) Magn Reson Med , vol.47 , pp. 1202-1210
    • Griswold, M.A.1    Jakob, P.M.2    Heidemann, R.M.3
  • 5
    • 32944476495 scopus 로고    scopus 로고
    • Identification, prognosis, and management of patients with carotid artery near occlusion
    • Fox AJ, EliasziwM, Rothwell PM, et al. Identification, prognosis, and management of patients with carotid artery near occlusion. AJNR Am J Neuroradiol 2005;26:2086-94
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 2086-2094
    • Fox, A.J.1    Eliasziw, M.2    Rothwell, P.M.3
  • 6
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods ofclinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods ofclinical measurement. Lancet 1986;1:307-10
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 7
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics 1977;33:159 -74
    • (1977) Biometrics , vol.33 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 8
    • 0037407959 scopus 로고    scopus 로고
    • Neurologic complications of cerebral angiography: Prospective analysis of 2,899 procedures and review of the literature
    • Willinsky RA, Taylor SM, TerBrugge K, et al. Neurologic complications of cerebral angiography: prospective analysis of 2,899 procedures and review of the literature. Radiology 2003;227:522-28
    • (2003) Radiology , vol.227 , pp. 522-528
    • Willinsky, R.A.1    Taylor, S.M.2    TerBrugge, K.3
  • 9
    • 0038304334 scopus 로고    scopus 로고
    • Duplex ultrasound and magneticresonance angiography compared with digital subtraction angiography in carotid artery stenosis: A systematic review
    • Nederkoorn PJ, van der Graaf Y, Hunink MG. Duplex ultrasound and magneticresonance angiography compared with digital subtraction angiography in carotid artery stenosis: a systematic review. Stroke 2003;34:1324 -32
    • (2003) Stroke , vol.34 , pp. 1324-1332
    • Nederkoorn, P.J.1    van der Graaf, Y.2    Hunink, M.G.3
  • 11
    • 33745243683 scopus 로고    scopus 로고
    • Agreement of multislice CT angiography and MR angiography in assessing the degreeofcarotidarterystenosisin consideration of different methods of postprocessing
    • Hacklander T, Wegner H, Hoppe S, et al. Agreement of multislice CT angiography and MR angiography in assessing the degreeofcarotidarterystenosisin consideration of different methods of postprocessing. J Comput Assist Tomogr 2006;30:433-42
    • (2006) J Comput Assist Tomogr , vol.30 , pp. 433-442
    • Hacklander, T.1    Wegner, H.2    Hoppe, S.3
  • 12
    • 33846421049 scopus 로고    scopus 로고
    • Evaluation of carotid artery stenosis with multisection CT and MR imaging: Influence of imaging modality and postprocessing
    • Lell M, Fellner C, Baum U, et al. Evaluation of carotid artery stenosis with multisection CT and MR imaging: influence of imaging modality and postprocessing. AJNR Am JNeuroradiol 2007;28:104-10
    • (2007) AJNR Am JNeuroradiol , vol.28 , pp. 104-110
    • Lell, M.1    Fellner, C.2    Baum, U.3
  • 13
    • 32944479205 scopus 로고    scopus 로고
    • Contrast-enhanced MR angiography of the carotid and vertebrobasilar circulations
    • Yang CW, Carr JC, Futterer SF, et al. Contrast-enhanced MR angiography of the carotid and vertebrobasilar circulations. AJNR Am J Neuroradiol 2005;26:2095-101
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 2095-2101
    • Yang, C.W.1    Carr, J.C.2    Futterer, S.F.3
  • 14
    • 33846528589 scopus 로고    scopus 로고
    • Supraaortic arteries: Contrast-enhanced MR angiography at 3.0 T-highly accelerated parallel acquisition for improved spatial resolution over an extended field of view
    • Nael K, Villablanca JP, Pope WB, et al. Supraaortic arteries: contrast-enhanced MR angiography at 3.0 T-highly accelerated parallel acquisition for improved spatial resolution over an extended field of view. Radiology 2007;242:600-09
    • (2007) Radiology , vol.242 , pp. 600-609
    • Nael, K.1    Villablanca, J.P.2    Pope, W.B.3
  • 15
    • 0036099935 scopus 로고    scopus 로고
    • Vessel contrast at three Tesla in time-of-flight magnetic resonance angiographyofthe intracranial and carotid arteries
    • Al-Kwifi O, Emery DJ, Wilman AH. Vessel contrast at three Tesla in time-of-flight magnetic resonance angiographyofthe intracranial and carotid arteries. Magn Reson Imaging2002;20:181-87
    • (2002) Magn Reson Imaging , vol.20 , pp. 181-187
    • Al-Kwifi, O.1    Emery, D.J.2    Wilman, A.H.3
  • 16
    • 33646363599 scopus 로고    scopus 로고
    • Spontaneous acute dissection of the internal carotid artery: High-resolution magnetic resonance imaging at 3.0 tesla with a dedicated surface coil
    • Bachmann R,Nassenstein I,Kooijman H, et al. Spontaneous acute dissection of the internal carotid artery: high-resolution magnetic resonance imaging at 3.0 tesla with a dedicated surface coil. Invest Radiol 2006;41:105-11
    • (2006) Invest Radiol , vol.41 , pp. 105-111
    • Bachmann, R.1    Nassenstein, I.2    Kooijman, H.3
  • 17
    • 33748082697 scopus 로고    scopus 로고
    • Intracranial time-resolved contrast-enhanced MR angiography at 3T
    • Cashen TA, Carr JC, Shin W, et al. Intracranial time-resolved contrast-enhanced MR angiography at 3T. AJNR Am J Neuroradiol 2006;27:822-29
    • (2006) AJNR Am J Neuroradiol , vol.27 , pp. 822-829
    • Cashen, T.A.1    Carr, J.C.2    Shin, W.3
  • 18
    • 33747813462 scopus 로고    scopus 로고
    • Isotropic high spatial resolution magnetic resonance angiography of the supra-aortic arteries using two-dimensional parallel imaging (iPAT2) at 3 Tesla: A feasibility study
    • Fenchel M, Nael K, Ruehm S, et al. Isotropic high spatial resolution magnetic resonance angiography of the supra-aortic arteries using two-dimensional parallel imaging (iPAT2) at 3 Tesla: a feasibility study. Invest Radiol 2006;41:545-52
    • (2006) Invest Radiol , vol.41 , pp. 545-552
    • Fenchel, M.1    Nael, K.2    Ruehm, S.3
  • 19
    • 33646729046 scopus 로고    scopus 로고
    • 3.0 Tesla contrast-enhanced MR angiography of carotid artery stents: In vitro measurements as compared with 1.5 Tesla
    • Hahnel S, Nguyen-Trong TH, Rohde S, et al. 3.0 Tesla contrast-enhanced MR angiography of carotid artery stents: in vitro measurements as compared with 1.5 Tesla. J Neuroradiol 2006;33:75-80
    • (2006) J Neuroradiol , vol.33 , pp. 75-80
    • Hahnel, S.1    Nguyen-Trong, T.H.2    Rohde, S.3
  • 20
    • 33646353706 scopus 로고    scopus 로고
    • Time-resolved contrast enhanced magnetic resonance angiography of the head and neck at 3.0 tesla: Initial results
    • Nael K, Michaely HJ, Villablanca P, et al. Time-resolved contrast enhanced magnetic resonance angiography of the head and neck at 3.0 tesla: initial results. Invest Radiol 2006;41:116- 4
    • (2006) Invest Radiol , vol.41 , pp. 116-124
    • Nael, K.1    Michaely, H.J.2    Villablanca, P.3
  • 21
    • 33746384612 scopus 로고    scopus 로고
    • High spatial-resolution CE-MRA of the carotid circulation with parallel imaging: Comparison of image quality between2 different acceleration factors at 3.0 Tesla
    • Nael K, Ruehm SG, Michaely HJ, et al. High spatial-resolution CE-MRA of the carotid circulation with parallel imaging: comparison of image quality between2 different acceleration factors at 3.0 Tesla. Invest Radiol 2006;41:391-99
    • (2006) Invest Radiol , vol.41 , pp. 391-399
    • Nael, K.1    Ruehm, S.G.2    Michaely, H.J.3
  • 22
    • 16844380763 scopus 로고    scopus 로고
    • Dynamic 3D MR angiography of intra- and extracranial vascular malformations at 3T: A technical note
    • Ziyeh S, Strecker R, Berlis A, et al. Dynamic 3D MR angiography of intra- and extracranial vascular malformations at 3T: a technical note. AJNR Am J Neuroradiol 2005;26:630 -34
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 630-634
    • Ziyeh, S.1    Strecker, R.2    Berlis, A.3
  • 23
    • 1642541669 scopus 로고    scopus 로고
    • Improved image quality of intracranial aneurysms: 3.0-T versus 1.5-T time-of-flight MR angiography
    • Gibbs GF, Huston J 3rd, Bernstein MA, et al. Improved image quality of intracranial aneurysms: 3.0-T versus 1.5-T time-of-flight MR angiography. AJNR Am J Neuroradiol 2004;25:84 -87
    • (2004) AJNR Am J Neuroradiol , vol.25 , pp. 84-87
    • Gibbs, G.F.1    Huston 3rd, J.2    Bernstein, M.A.3
  • 24
    • 12744261213 scopus 로고    scopus 로고
    • 3.0-Tesla MR angiography of intracranial aneurysms: Comparison of time-of-flight and contrast-enhanced techniques
    • Gibbs GF, Huston J 3rd, Bernstein MA, et al. 3.0-Tesla MR angiography of intracranial aneurysms: comparison of time-of-flight and contrast-enhanced techniques. J Magn Reson Imaging2005;21:97-102
    • (2005) J Magn Reson Imaging , vol.21 , pp. 97-102
    • Gibbs, G.F.1    Huston 3rd, J.2    Bernstein, M.A.3
  • 25
    • 33747151050 scopus 로고    scopus 로고
    • An integrated automated analysis method for quantifying vessel stenosis and plaque burden from carotid MRI images: Combined postprocessing of MRA and vessel wall MR
    • Epub Jun 29
    • dame IM, de Koning PJ, Lelieveldt BP, et al. An integrated automated analysis method for quantifying vessel stenosis and plaque burden from carotid MRI images: combined postprocessing of MRA and vessel wall MR. Stroke 2006;37: 2162-4. Epub 2006 Jun 29
    • (2006) Stroke 2006 , vol.37 , pp. 2162-2164
    • dame, I.M.1    de Koning, P.J.2    Lelieveldt, B.P.3
  • 26
    • 0345600047 scopus 로고    scopus 로고
    • Automated segmentation and analysis of vascular structures in magnetic resonance angiographicimages
    • de Koning PJ, Schaap JA, Janssen JP, et al. Automated segmentation and analysis of vascular structures in magnetic resonance angiographicimages. Magn Reson Med 2003;50:1189-98
    • (2003) Magn Reson Med , vol.50 , pp. 1189-1198
    • de Koning, P.J.1    Schaap, J.A.2    Janssen, J.P.3
  • 27
    • 0035140817 scopus 로고    scopus 로고
    • Quantitative analysis of vascular morphology from3D MR angiograms: Invitro andinvivo results
    • Frangi AF, Niessen WJ, Nederkoorn PJ, et al. Quantitative analysis of vascular morphology from3D MR angiograms: invitro andinvivo results. MagnReson Med 2001;45:311-22
    • (2001) MagnReson Med , vol.45 , pp. 311-322
    • Frangi, A.F.1    Niessen, W.J.2    Nederkoorn, P.J.3
  • 28
    • 1842481954 scopus 로고    scopus 로고
    • Semiautomatic segmentation and stenosis quantification of 3D contrast-enhanced MR angiograms ofthe internal carotid artery
    • van Bemmel CM, Viergever MA, Niessen WJ. Semiautomatic segmentation and stenosis quantification of 3D contrast-enhanced MR angiograms ofthe internal carotid artery. Magn Reson Med 2004;51:753-60
    • (2004) Magn Reson Med , vol.51 , pp. 753-760
    • van Bemmel, C.M.1    Viergever, M.A.2    Niessen, W.J.3
  • 29
    • 1642294566 scopus 로고    scopus 로고
    • New vessel analysis tool for morphometric quantification and visualization of vessels in CT and MR imaging data sets
    • Boskamp T, Rinck D, Link F, et al. New vessel analysis tool for morphometric quantification and visualization of vessels in CT and MR imaging data sets. Radiographics 2004;24:287-97
    • (2004) Radiographics , vol.24 , pp. 287-297
    • Boskamp, T.1    Rinck, D.2    Link, F.3
  • 30
    • 0036961882 scopus 로고    scopus 로고
    • A review on MR vascular image processing: Skeleton versus nonskeleton approach
    • Suri JS, Liu K, Reden L, et al. A review on MR vascular image processing: skeleton versus nonskeleton approach. IEEE Trans Inf Technol Biome 0d 2002; 6(pt2):338-50
    • (2002) IEEE Trans Inf Technol Biome 0d , vol.6 , Issue.PT2 , pp. 338-350
    • Suri, J.S.1    Liu, K.2    Reden, L.3
  • 31
    • 0036964396 scopus 로고    scopus 로고
    • A review on MR vascular image processing algorithms: Acquisition and prefiltering
    • Suri JS, Liu K, Reden L, et al. A review on MR vascular image processing algorithms: acquisition and prefiltering. IEEE Trans Inf Technol Biomed 2002; 6(pt 1):324 -37
    • (2002) IEEE Trans Inf Technol Biomed , vol.6 , Issue.PART 1 , pp. 324-337
    • Suri, J.S.1    Liu, K.2    Reden, L.3
  • 32
    • 1842555270 scopus 로고    scopus 로고
    • Carotid artery stenosis: Reproducibility of automated 3D CT angiographyanalysis method
    • Zhang Z, Berg MH, Ikonen AE, et al. Carotid artery stenosis: reproducibility of automated 3D CT angiographyanalysis method. Eur Radiol 2004;14:665-72
    • (2004) Eur Radiol , vol.14 , pp. 665-672
    • Zhang, Z.1    Berg, M.H.2    Ikonen, A.E.3
  • 33
    • 33846432396 scopus 로고    scopus 로고
    • CT angiographic analysis of carotid artery stenosis: Comparison of manual assessment, semiautomatic vessel analysis, and digital subtraction angiography
    • Silvennoinen HM, Ikonen S, Soinne L, et al. CT angiographic analysis of carotid artery stenosis: comparison of manual assessment, semiautomatic vessel analysis, and digital subtraction angiography. AJNR Am J Neuroradiol 2007;28:97-103
    • (2007) AJNR Am J Neuroradiol , vol.28 , pp. 97-103
    • Silvennoinen, H.M.1    Ikonen, S.2    Soinne, L.3
  • 34
    • 0035186294 scopus 로고    scopus 로고
    • Maximum stenosis of extracranial internal carotid artery: Effect of luminal morphology on stenosis measurement byusing CT angiography and conventional DSA
    • Hirai T, Korogi Y, Ono K, et al. Maximum stenosis of extracranial internal carotid artery: effect of luminal morphology on stenosis measurement byusing CT angiography and conventional DSA. Radiology2001;221:802-09
    • (2001) Radiology , vol.221 , pp. 802-809
    • Hirai, T.1    Korogi, Y.2    Ono, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.