메뉴 건너뛰기




Volumn 21, Issue 11, 2008, Pages

Detection of proton NMR signal in the earth's magnetic field at an urban laboratory environment without shielding

Author keywords

[No Author keywords available]

Indexed keywords

FADING (RADIO); MAGNETIC FIELDS; MAGNETIC RESONANCE; NUCLEAR MAGNETIC RESONANCE; NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY; PROTONS; RELAXATION PROCESSES; SHIELDING; SIGNAL TO NOISE RATIO; SPIN DYNAMICS; SQUIDS; SUPERCONDUCTING MAGNETS;

EID: 58149518694     PISSN: 09532048     EISSN: 13616668     Source Type: Journal    
DOI: 10.1088/0953-2048/21/11/115009     Document Type: Article
Times cited : (15)

References (18)
  • 1
    • 0027908997 scopus 로고
    • A high-temperature superconducting receiver for nuclear magnetic resonance microscopy
    • Black R D, Roemer P B and Mueller O M 1993 A high-temperature superconducting receiver for nuclear magnetic resonance microscopy Science 259 793-5
    • (1993) Science , vol.259 , Issue.5096 , pp. 793-795
    • Black, R.D.1    Roemer, P.B.2    Mueller, O.M.3
  • 2
    • 0032345068 scopus 로고    scopus 로고
    • Application of superconducting quantum interference devices to nuclear magnetic resonance
    • Greenberg Y S 1998 Application of superconducting quantum interference devices to nuclear magnetic resonance Rev. Mod. Phys. 70 175-222
    • (1998) Rev. Mod. Phys. , vol.70 , Issue.1 , pp. 175-222
    • Greenberg, Y.S.1
  • 7
    • 4243202770 scopus 로고    scopus 로고
    • Simultaneous magnetoencephalography and SQUID detected nuclear MR in microtesla magnetic fields mT
    • Volegov P, Matlachov A N, Espy M A, George J S and Kraus R H Jr 2004 Simultaneous magnetoencephalography and SQUID detected nuclear MR in microtesla magnetic fields mT Magn. Reson. Med. 52 467-70
    • (2004) Magn. Reson. Med. , vol.52 , Issue.3 , pp. 467-470
    • Volegov, P.1    Matlachov, A.N.2    Espy, M.A.3    George, J.S.4    Kraus, R.H.5
  • 10
    • 34247893994 scopus 로고    scopus 로고
    • Liquid state nuclear magnetic resonance at low fields using a nitrogen cooled superconducting quantum interference device
    • Zhang Y, Qiu L, Krause H-J, Hartwig S, Burghoff M and Trahms L 2007 Liquid state nuclear magnetic resonance at low fields using a nitrogen cooled superconducting quantum interference device Appl. Phys. Lett. 90 182503
    • (2007) Appl. Phys. Lett. , vol.90 , Issue.18 , pp. 182503
    • Zhang, Y.1    Qiu, L.2    Krause, H.-J.3    Hartwig, S.4    Burghoff, M.5    Trahms, L.6
  • 12
    • 35348825462 scopus 로고    scopus 로고
    • SQUID-detected magnetic resonance imaging in microtesla fields
    • Clarke J, Hatridge M and Möle M 2007 SQUID-detected magnetic resonance imaging in microtesla fields Annu. Rev. Biomed. Eng. 9 389-413
    • (2007) Annu. Rev. Biomed. Eng. , vol.9 , Issue.1 , pp. 389-413
    • Clarke, J.1    Hatridge, M.2    Möle, M.3
  • 13
    • 34548022858 scopus 로고    scopus 로고
    • Nuclear magnetic resonance in the earth's magnetic field using a nitrogen-cooled superconducting quantum interference device
    • Qiu L Q, Zhang Y, Krause H-J, Braginski A I, Burghoff M and Trahms L 2007 Nuclear magnetic resonance in the earth's magnetic field using a nitrogen-cooled superconducting quantum interference device Appl. Phys. Lett. 91 072505
    • (2007) Appl. Phys. Lett. , vol.91 , Issue.7 , pp. 072505
    • Qiu, L.Q.1    Zhang, Y.2    Krause, H.-J.3    Braginski, A.I.4    Burghoff, M.5    Trahms, L.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.